Digital Orthodontics: Posterior crossbite correction and arch expansion with directly 3-dimensional printed clear aligners

Jae Hyun Park, Miyoung Sim, Hyewon Choi, Hyun-Hee Choo · 2025

Read Digital Orthodontics: Posterior crossbite correction and arch expansion with directly 3-dimensional printed clear aligners by Jae Hyun Park, Miyoung Sim, Hyewon Choi, Hyun-Hee Choo (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-12916051.txt.

Description

Printed clear aligners that fix a back-tooth bite fault are reported by Jae Hyun Park, Miyoung Sim, Hyewon Choi, and Hyun-Hee Choo in work dated 2025. Back crossbite and a narrow lower arch were long treated with fixed braces. Pressed plastic aligners had shown weak force for such moves. The team used aligners printed at once from a body-safe resin for a woman aged twenty-six.

A full digital plan guided care, with twenty-six aligners made over thirty-one weeks. The crossbite closed, the arch widened, and back teeth kept their tilt. Layered scans showed drift back of less than half a unit at one year. Printed aligners may thus match harder cases.

Catalog record

CREATORJae Hyun Park, Miyoung Sim, Hyewon Choi, Hyun-Hee Choo
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE11 KB
VERSION1.0
LICENSECC BY 4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/articles/PMC12916051

Browse the full library · About the Tower of Babel