Emergency Plug-assisted Retrograde Transvenous Obliteration Using an Optimo 9-Fr Balloon Guiding Catheter: A Case Report

Yohei Takeshita, Junji Moriya, Yo Matsui, Shintaro Chiba · 2025

Read Emergency Plug-assisted Retrograde Transvenous Obliteration Using an Optimo 9-Fr Balloon Guiding Catheter: A Case Report by Yohei Takeshita, Junji Moriya, Yo Matsui, Shintaro Chiba (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-12813557.txt.

Description

Yohei Takeshita and co-authors describe an emergency fix for a burst stomach vein in a 2025 case report. The patient, a man of fifty-nine with liver cirrhosis from alcohol, had swollen veins in the stomach fundus that had ruptured, a bleed that demands fast action.

The standard tool for sealing such veins from inside was not at hand, so the team used a balloon guiding catheter instead. Under balloon blockage they mapped the vein tangle, placed a vascular plug, and fed in gelatin sponge particles through a fine catheter. The vein closed fully with no complications, and later scans and camera checks showed clear improvement. The authors present the swap as a workable option when stock runs short.

Catalog record

CREATORYohei Takeshita, Junji Moriya, Yo Matsui, Shintaro Chiba
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE11 KB
VERSION1.0
LICENSECC BY 4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/articles/PMC12813557

Browse the full library · About the Tower of Babel