Transradial vs transfemoral secondary access outcomes in transcatheter aortic valve replacement: an updated systematic review and meta-analysis
Hashim Ishfaq, Reyan Hussain Shaikh, Emaan Fatima, Mian Muinuddin Jamshed, Hamza Ishfaq, Abdulkareem Lukan, Hina Inam, Muhammad Bilal Ibrahim, Hafeez Shaka · 2025
Read Transradial vs transfemoral secondary access outcomes in transcatheter aortic valve replacement: an updated systematic review and meta-analysis by Hashim Ishfaq, Reyan Hussain Shaikh, Emaan Fatima, Mian Muinuddin Jamshed, Hamza Ishfaq, Abdulkareem Lukan, Hina Inam, Muhammad Bilal Ibrahim, Hafeez Shaka (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-12756211.txt.
Description
Hashim Ishfaq and co-authors pool in 2025 studies comparing two wrist versus leg routes for the backup access line during valve replacement through a catheter. The main valve goes in through a main route, but a second line is needed, and its site may drive bleeding and vessel harm. Searches of three databases gathered studies that compared wrist and upper leg backup access head to head.
Seven studies with over six thousand patients qualified. Wrist access tied to far lower odds of death within thirty days, and to lower odds of stroke and passing clots. Checks that drop one study at a time, and splits by main route, tested how firm the picture is. The authors favor the wrist for the backup line.
Catalog record
| CREATOR | Hashim Ishfaq, Reyan Hussain Shaikh, Emaan Fatima, Mian Muinuddin Jamshed, Hamza Ishfaq, Abdulkareem Lukan, Hina Inam, Muhammad Bilal Ibrahim, Hafeez Shaka |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 36 KB |
| VERSION | 1.0 |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |