Retained fragmented Raytec gauze eluding an alleged correct postoperative count following cardiothoracic surgery: case report of a rare “never event”

Marco Lizwan, Philip Y. K. Pang · 2025

Read Retained fragmented Raytec gauze eluding an alleged correct postoperative count following cardiothoracic surgery: case report of a rare “never event” by Marco Lizwan, Philip Y. K. Pang (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-12750874.txt.

Description

Operating rooms count every sponge, yet a count can be right and a fragment still left behind. Marco Lizwan and Philip Pang report such a never event in a 2025 case report. Their patient, a 69-year-old man, had valve replacement and bypass surgery for severe heart disease.

All counts were verified correct when the operation ended. A routine chest X-ray then showed two thin radio-opaque strands near the lower sternum. A second operation found them attached to the chest wall: marker strands, three and two centimeters long, torn from surgical gauzes. The patient recovered well. The authors urge teams to inspect gauze integrity, not just gauze counts, and to consider tracking technology.