Read Catheter-induced left main dissection during valve-in-valve TAVI: a rare complication of coronary protection strategy by Alessandro Comis, Sebastiano Immè, Claudia Tamburino, Corrado Tamburino, Julio Echarte, Marie-Luise Dikou, Andreas Mitsis (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-12728411.txt.

Description

Alessandro Comis and six co-authors report a rare mishap during a valve in valve heart procedure. The patient was a woman aged eighty-three whose earlier replacement valve had failed. Scans showed her heart artery opening sat low, raising the risk that the new valve would block it. The team placed a protective wire in the artery as a guard.

After the new valve was released, imaging showed a tear in the main heart artery that blocked flow. The wire had likely shifted during release. The patient had severe chest pain and a new electric fault in the heart. Urgent stents restored flow and eased symptoms. The authors say this is the first such case reported during protective wiring.

Catalog record

CREATORAlessandro Comis, Sebastiano Immè, Claudia Tamburino, Corrado Tamburino, Julio Echarte, Marie-Luise Dikou, Andreas Mitsis
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE4 KB
VERSION1.0
LICENSECC BY 4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/articles/PMC12728411

Browse the full library · About the Tower of Babel