Measurement study of the “optimal” screw axis location and its angles with the first and second metacarpals based on X imaging of the scaphoid bone
JingQuan Guo, Qianwen Jia, Bo Wu, Fei Xiao, Keke Cheng, Tianrun Lei · 2025
Read Measurement study of the “optimal” screw axis location and its angles with the first and second metacarpals based on X imaging of the scaphoid bone by JingQuan Guo, Qianwen Jia, Bo Wu, Fei Xiao, Keke Cheng, Tianrun Lei (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-12696132.txt.
Description
JingQuan Guo and co-authors measure a bone based guide for wrist screw surgery in a 2025 study. Fixing a broken scaphoid with a screw through the palm side depends on hitting the right entry point and angle, usually judged by eye or repeated X-rays. The team asked whether the thumb and index finger bones give a steadier reference.
On X-rays from one hundred fifty one healthy adults, the angle between the ideal screw line and the second metacarpal barely varied between people. The angle to the first metacarpal shifted with thumb pose, nearly vanishing when the thumb spread. The authors propose the metacarpal angles as a standard reference to cut guesswork and radiation in the operating room.
Catalog record
| CREATOR | JingQuan Guo, Qianwen Jia, Bo Wu, Fei Xiao, Keke Cheng, Tianrun Lei |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 28 KB |
| VERSION | 1.0 |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |