3D-printed tantalum artificial vertebral body or titanium mesh in anterior column reconstruction post-spondylectomy for thoracic vertebral tumors: a retrospective comparative cohort study and finite element analysis
Hui Lv, Meitao Xu, Qiuchi Ai, Fuyou Wang, Zhongrong Zhang, Tianyong Hou · 2025
Read 3D-printed tantalum artificial vertebral body or titanium mesh in anterior column reconstruction post-spondylectomy for thoracic vertebral tumors: a retrospective comparative cohort study and finite element analysis by Hui Lv, Meitao Xu, Qiuchi Ai, Fuyou Wang, Zhongrong Zhang, Tianyong Hou (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-12683856.txt.
Description
Hui Lv and co-authors published a surgical study in 2025 comparing spine implants after tumor removal in the chest region. Rebuilding the front column after taking out a whole vertebra is unsettled. The team compared a 3D-printed tantalum vertebral body against standard titanium mesh in patients, and added computer stress models of three implant types.
Both groups had similar operations, but tantalum patients reported far less pain at two years and every graft fused, versus under forty percent for mesh. Mesh sank into bone far more and a third of its patients needed revision for broken rods. Stress models showed mesh carrying many times the peak stress. The authors favor printed tantalum for this reconstruction.
Catalog record
| CREATOR | Hui Lv, Meitao Xu, Qiuchi Ai, Fuyou Wang, Zhongrong Zhang, Tianyong Hou |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 45 KB |
| VERSION | 1.0 |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |