Sensorless model-based tension control for a cable-driven exosuit

Elena Bardi, Adrian Esser, Peter Wolf, Marta Gandolla, Emilia Ambrosini, Alessandra Pedrocchi, Robert Riener · 2024

Read Sensorless model-based tension control for a cable-driven exosuit by Elena Bardi, Adrian Esser, Peter Wolf, Marta Gandolla, Emilia Ambrosini, Alessandra Pedrocchi, Robert Riener (2024) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-11729527.txt.

Description

Elena Bardi and co-authors removed the force sensor from a cable-driven arm exosuit, in a 2024 study. Such suits help weak arms lift against gravity, but tension sensors add cost, bulk, and fuss at the limb. The team redesigned the suit for easy motion, then taught a model the system's friction on a mannequin bench, so software could infer tension instead of measuring it.

Seventeen healthy users raised and lowered an arm with the suit. Torque tracking landed within about a fifth of the target at half gravity support. Shoulder muscle effort fell by roughly a third while raising. Motion grew less smooth, though, a trade the team flags for work.

Catalog record

CREATORElena Bardi, Adrian Esser, Peter Wolf, Marta Gandolla, Emilia Ambrosini, Alessandra Pedrocchi, Robert Riener
YEAR2024
COLLECTIONPAPERS
FORMATTXT
FILE SIZE44 KB
VERSION1.0
LICENSECC BY 4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/articles/PMC11729527

Browse the full library · About the Tower of Babel