Pacemaker Pocket Erosion: A Critical Issue Requiring Immediate Attention
Colin McGuire, Jeniffer Naitore, Vijay Ramu · 2024
Read Pacemaker Pocket Erosion: A Critical Issue Requiring Immediate Attention by Colin McGuire, Jeniffer Naitore, Vijay Ramu (2024) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-11724444.txt.
Description
McGuire, Naitore, and Ramu present a case report from twenty twenty-four on pacemaker pocket erosion with infection. A seventy-seven-year-old man arrives with infection signs and exposed device skin breakdown. Cultures from blood and wound grow the same staph germ. The full device and leads are removed successfully. Antibiotics follow, and he leaves hospital two days later. Device infections are rising as populations age, the authors note. Frailty and shallow placement raise the risk.
Early removal, within a day here, drives the good outcome. His earlier blood infection might have been cured by removal then. Timing-based removal rules are proposed for future guidelines. Close follow-up spans infection, heart, and wound teams.
Catalog record
| CREATOR | Colin McGuire, Jeniffer Naitore, Vijay Ramu |
|---|---|
| YEAR | 2024 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 18 KB |
| VERSION | 1.0 |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |