Inserting a VA-ECMO cannula through an inferior vena cava filter during extracorporeal cardiopulmonary resuscitation
Genhua Mu, Rongliang Xu, Yiyun Wang, Chun Pan, Jianfeng Xie · 2024
Read Inserting a VA-ECMO cannula through an inferior vena cava filter during extracorporeal cardiopulmonary resuscitation by Genhua Mu, Rongliang Xu, Yiyun Wang, Chun Pan, Jianfeng Xie (2024) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-11653857.txt.
Description
Genhua Mu and four co-authors report a 2024 case where a heart-lung machine line was threaded through a vein filter mid-rescue. A huge lung clot had stopped the patient's heart, and the machine was the last support. The filter, placed to trap clots, sat right in the path the drainage tube had to take.
The team had first pulled clot out by suction and set the filter. When the heart stopped, they passed the tube through the filter's mesh during chest compressions. The machine took over, the patient steadied, and brain function came back whole. The case shows the route can work in a crisis.
Catalog record
| CREATOR | Genhua Mu, Rongliang Xu, Yiyun Wang, Chun Pan, Jianfeng Xie |
|---|---|
| YEAR | 2024 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 9 KB |
| VERSION | 1.0 |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |