Comparative Analysis of Force-Sensitive Resistors and Triaxial Accelerometers for Sitting Posture Classification
Zhuofu Liu, Zihao Shu, Vincenzo Cascioli, Peter W. McCarthy · 2024
Read Comparative Analysis of Force-Sensitive Resistors and Triaxial Accelerometers for Sitting Posture Classification by Zhuofu Liu, Zihao Shu, Vincenzo Cascioli, Peter W. McCarthy (2024) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-11645039.txt.
Description
A chair that knows how you sit could warn against postures that harm health, and Zhuofu Liu and co-authors compared two sensor recipes for the job. They fitted seats with four force-sensitive resistors and, separately, two triaxial accelerometers, then raced five machine learning classifiers on the readings. The k-nearest neighbor method won, tuned to a city block distance with three neighbors.
Accelerometers classified posture more accurately than the resistors, reaching 99.0 percent on test data against 95.4, and processed slightly faster. The authors conclude the accelerometers, already cheap and compact, are the better pick for posture monitoring.
Catalog record
| CREATOR | Zhuofu Liu, Zihao Shu, Vincenzo Cascioli, Peter W. McCarthy |
|---|---|
| YEAR | 2024 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 20 KB |
| VERSION | 1.0 |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |