A Comparison of the Sensitivity and Cellular Detection Capabilities of Magnetic Particle Imaging and Bioluminescence Imaging

Sophia Trozzo, Bijita Neupane, Paula J. Foster · 2024

Read A Comparison of the Sensitivity and Cellular Detection Capabilities of Magnetic Particle Imaging and Bioluminescence Imaging by Sophia Trozzo, Bijita Neupane, Paula J. Foster (2024) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-11598277.txt.

Description

Sophia Trozzo, Bijita Neupane and Paula Foster compared in 2024 two ways of tracking labeled cells in living animals. One way, bioluminescence, reads light from cells engineered to glow. The other, magnetic particle imaging, detects iron oxide particles directly. Mouse breast cancer cells carried both labels, then were imaged in dishes and after injection under the skin.

In cell samples, both signals tracked cell number closely. In living mice, each method hit limits. Fur, depth and scattered light hid the glow for some animals. The magnetic method's background swamped small cell numbers, and counts could not be read exactly from body images. The authors say knowing these weak points is the first step to fixes. They favor combining methods so each covers the other's blind spots.

Catalog record

CREATORSophia Trozzo, Bijita Neupane, Paula J. Foster
YEAR2024
COLLECTIONPAPERS
FORMATTXT
FILE SIZE44 KB
VERSION1.0
LICENSECC BY 4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/articles/PMC11598277

Browse the full library · About the Tower of Babel