Read The “coupler” technique for endoscopic removal of a threaded inside stent that migrated above tight hilar strictures by Sho Kitagawa, Narito Murakoshi, Shori Ishikawa (2023) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/pmc-10715900.txt.
Description
Sho Kitagawa, Narito Murakoshi, and Shori Ishikawa present a 2023 case report on removing a migrated bile duct stent. Threaded plastic stents placed above the papilla can treat tight narrowings near the liver. A seventy-five-year-old man with scarring disease of the bile ducts needed such stents.
One stent slipped fully into a side branch while a second stent was being placed. Pulling its retrieval thread failed to free it, and the bent path blocked other tools. The authors devised a coupler technique using a tapered delivery sheath passed over a guidewire through the narrowing. The approach reached the stuck stent and removed it through the scope. They offer the method as a simple rescue for a tricky complication.