Dielectrophoresis and ζ-potential as potential low-cost complements to patch clamp for measurement of cell electrophysiology
Rashedul Hoque, Fatima H Labeed, Srdjan Cirovic, Michael Pycraft Hughes · 2026
Read Dielectrophoresis and ζ-potential as potential low-cost complements to patch clamp for measurement of cell electrophysiology by Rashedul Hoque, Fatima H Labeed, Srdjan Cirovic, Michael Pycraft Hughes (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/plos-pone-0356467.txt.
Introduction
Rashedul Hoque and three colleagues explore cheaper ways to measure the electrical state of living cells, in this 2026 study. The standard tool, patch clamp, reads a single cell through a fine glass pipette; it is accurate but slow, costly, and demands rare skill. The team instead used two techniques that read thousands of cells in under a minute, one based on how cells move in an electric field and one based on light scattering.
Working with a human bladder cancer cell line, they applied three drugs known to alter cell electrical behavior and compared the cheap methods' readings with published patch clamp results. The field-based technique matched patch clamp values closely for membrane voltage and conductance. The authors argue such methods could open routine electrical testing of cells to ordinary labs and speed up drug screening.
Catalog record
| CREATOR | Rashedul Hoque, Fatima H Labeed, Srdjan Cirovic, Michael Pycraft Hughes |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 39245 |
| LICENSE | CC_BY |
| RIGHTS | CC BY |
| SOURCE | PLOS |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Dielectrophoresis and ζ-potential as potential low-cost complements to patch clamp for measurement of cell electrophysiology Rashedul Hoque, Fatima H Labeed, Srdjan Cirovic, Michael Pycraft Hughes ABSTRACT Cell electrophysiology is a useful measure of cell function, including ionic state and channel activity, and the way these are altered by pharmacological intervention. However, measurement of whole-cell electrical properties such as resting membrane potential Vm and membrane whole-cell capacitance and conductance is difficult, which has limited the more widespread adoption of electrophysiology in cell biology and drug discovery. The gold-standard method for acquiring this data is patch clamp, a method of measuring single cells that uses a micromanipulated micropipette in contact with the cell surface. Measurement is difficult, slow, and requires a highly skilled operator, whilst automated alternatives are expensive to run. Other methods such as flow cytometry are unable to provide absolute values of Vm, or measure conductance and capacitance characteristics. Dielectrophoresis (DEP) and electrophoretic light scattering (ELS) have recently been shown to provide useful methods of directly measuring absolute Vm and other parameters, whilst examining many more cells (typically tens of thousands in under a minute). In this paper we use DEP and ELS to examine the electrophysiology of human bladder carcinoma cell line HTB-9 following treatment with ATP, glibenclamide and tetraethylammonium, and compare the results to published data obtained by patch clamp. Results indicate that DEP yields Vm and membrane conductance values that are highly comparable to data from patch clamp, at high speed and low cost, demonstrating the usefulness of techniques such as DEP and ELS for electrophysiological study. 1. Introduction Cell electrophysiology describes the role of electrical phenomena in cell function [ 1 ]. As well as providing the physical basis for the function of excitable cells such as muscle and nerve, electrophysiological phenomena regulate many cellular functions in non-excitable cells through the use of ion channels which partition ions between the cytoplasm and extracellular space. Within the cytosol, these ions then regulate protein and organelle function. The quantity of ions passing through ion channels in the membrane can be measured as channel conductance; the diffusion potentials arising from unequal concentrations across the membrane gives rise to an electrical (membrane) potential V m , which then acts across the insulating component of the membrane as a capacitor. A key role of the study of cell electrophysiology study is to understand the effect of pharmaceutical interventions such as channel blockers on cell physiology. As well as playing a vital role in cell function, changes in cell electrophysiology are also associated with cell dysfunction. For example, cancer cells differ from their healthy counterparts in membrane potential [ 2 ] and membrane capacitance [ 3 ]; it has been shown that alteration of the cell’s electrical phenotype may play a role in cancer metastasis [ 4 ] and may offer a potential route to reverting to a pre-cancerous phenotype [ 5 ]. The gold standard method of measuring cellular properties such as the electrical potential, resistance and capacitance of the cell membrane is whole-cell patch clamp [ 6 – 8 ], wherein a current is measured through a saline-filled micropipette in contact with the cell cytoplasm via a small puncture in the membrane. Achieving this contact is a difficult and complex task; it requires identifying cells that can both provide a suitable seal and remain functional for the duration of the experiment, followed by careful micromanipulation of a micropipette tip to the surface of a cell a few microns across. Highly skilled operators are few and far between, and a skilled patcher can rarely measure more than a few cells per day. This in turn lends itself to operator bias, since only a small number of cells can be selected for patching, and that anecdotally these are typically the larger cells. Conversely, automated patch clamp systems [ 9 ] use microfluidic channels, where a reduced pressure and accompanying fluid flow draws single cells to a microscopic hole in the chip floor. This hole is then used to perform the patch. This allows tens of cells (typically 20–30) to be studied in parallel, and lack operator bias since no operator is involved in cell selection; however, these systems are often very expensive, with high initial purchase costs and expensive consumables. Despite the importance of cell electrophysiology in areas such as cancer biology, the complexity and low throughput of single-cell analysis by patch clamp means that the field remains difficult to study for most laboratories. There is therefore a need to find alternative methods of electrophysiology assessment using low-cost, high-throughput, and ideally off-the-shelf instruments. Two approaches which have shown to offer potential as alternatives to patch clamp are dielectrophoresis (DEP), which measures the passive electrical properties of cells [ 10 ], and electrophoretic light scattering (ELS) which measures the ζ-potential, the electrical potential a short distance (ca. 1nm) outside the cell’s outer surface [ 11 ]. Both measure cell movement in electric fields to evaluate different electrical properties; both typically study tens of thousands of cells in under a minute, using disposable chips or cuvettes and requiring no operator skill beyond loading the consumables, making them much more widely amenable for cell electrophysiology than patch clamp. DEP uses non-uniform AC fields across a wide frequency range to determine a spectrum of mean cell movement. This “DEP spectrum” is then analysed using a theoretical model [ 12 – 14 ], with the best-fit model providing an estimated parameter set typically yielding the effective capacitance C eff and conductance G eff per unit area of the cell membrane, and the cytoplasm conductivity σ cyto . It has also been shown that analysis of DEP-derived σ cyto as a function of medium conductivity σ med yields a value of V m that is highly comparable to patch clamp in cells ranging from blood to cancer [ 15 ], to yeast cells with different biofilm-forming capacity [ 16 ], to the transformation of primary chondrocytes into fibroblasts in culture [ 17 ]. Conversely, ELS has been used very infrequently in cell biology. It measures the extracellular surface potential at the cell’s hydrodynamic plane of shear, where water molecules and ions are no longer hydrostatically bound to the cell surface (typically around 1nm from the surface itself). This voltage, known as the ζ-potential, is widely used in solution chemistry to assess colloidal stability [ 18 ]. ELS measures this by observing the velocity of suspensoids in response to an imposed uniform DC field, by measuring the light scattered by the moving particles [ 11 ]. The standard model of ζ-potential is that it is generated purely by surface chemistry [ 18 ], but substantial evidence over decades [ 19 ] suggests it is altered by V m , most likely by capacitive coupling across the cell membrane and associated electrical double layers [ 20 – 23 ]. The movement of ζ-potential and V m can be tracked in real time, for example in depolarised cardiomyocytes [ 24 ] and red blood cells suspended in low ionic strength media [ 25 ]. This effect allows cells to alter their interaction with their environment, including alteration of extracellular ion concentration [ 25 ], antibody-surface binding [ 26 ] and cell-surface