Read A preliminary comparison of prosthetic socket liner strain determined using digital image correlation and finite element analysis by Mohammadreza Freidouny, Michael L Madigan, Carson Squibb, Masaki Hada, Abbie Bailey, Trevor Johnson, Brian Kaluf, Michael K Philen (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/plos-pone-0353881.txt.

Description

Freidouny and colleagues measured stretch inside a false-limb socket liner in a 2026 early study. How a liner stretches against the skin affects comfort and fit for people who wear a leg prosthesis. Computer models often predict that stretch, but their guesses are rarely checked against direct measures.

One volunteer with a below-knee limb wore the liner through two stepping tasks while cameras tracked a dotted pattern on its surface. Camera measures were then set beside model predictions for the same tasks. Matching the two would build trust in models used to shape sockets. Even as a small first test, it shows a practical way to check fit science against real movement.

Catalog record

CREATORMohammadreza Freidouny, Michael L Madigan, Carson Squibb, Masaki Hada, Abbie Bailey, Trevor Johnson, Brian Kaluf, Michael K Philen
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE31828
LICENSECC_BY
RIGHTSCC BY
SOURCEPLOS

Source: https://doi.org/10.1371/journal.pone.0353881

Browse the full library · About the Tower of Babel