Research on the anti-pull performance of a novel small-diameter steel tube-stud grouting connector
Ming-su Zhou, En-he Bao, Cheng-jun Luo, Jian-fa Wang, Yong-song Wu, Chang-jian Xiao · 2026
Read Research on the anti-pull performance of a novel small-diameter steel tube-stud grouting connector by Ming-su Zhou, En-he Bao, Cheng-jun Luo, Jian-fa Wang, Yong-song Wu, Chang-jian Xiao (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/plos-pone-0353244.txt.
Description
Zhou and colleagues, in a 2026 engineering study, test a new connector that ties steel facade panels to a building's frame. Prefabricated steel walls need joints that are strong, cheap, and easy to fit on site. Their design grouts a stud inside a small steel tube, borrowing from sleeve grouting used elsewhere in construction. Eighteen test pieces were pulled until they failed, and computer models replayed the tests.
Strain grew from the stud's ends outward, and the models matched the real failures closely. The connector held up well even with weak grout and a shallow stud embedment, which cuts cost and eases site work. A formula the team derived for the load at which the connector yields predicted test results with small error. The authors offer the detail and its design math as a ready option for prefabricated steel facades, filling a gap in standards.
Catalog record
| CREATOR | Ming-su Zhou, En-he Bao, Cheng-jun Luo, Jian-fa Wang, Yong-song Wu, Chang-jian Xiao |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 54470 |
| LICENSE | CC_BY |
| RIGHTS | CC BY |
| SOURCE | PLOS |