Impact of axial length correction in high intraocular pressure eyes on intraocular lens power calculation
Yuri Kosaka, Takashi Kojima, Akeno Tamaoki, Yuki Takagi, Ayako Sawaki, Tsuyoshi Nogami, Tatsushi Kaga · 2026
Read Impact of axial length correction in high intraocular pressure eyes on intraocular lens power calculation by Yuri Kosaka, Takashi Kojima, Akeno Tamaoki, Yuki Takagi, Ayako Sawaki, Tsuyoshi Nogami, Tatsushi Kaga (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/plos-pone-0349117.txt.
Description
Yuri Kosaka and colleagues examined how high pressure inside the eye distorts cataract surgery planning. Surgeons calculate the artificial lens power from the eye's length, but pressure stretches the eye slightly, and when pressure drops the eye shrinks back, throwing off the calculation. The team reviewed nineteen eyes operated on for high pressure and compared measurements before and after.
Eye length and pressure moved together moderately, and each unit of pressure drop shortened the eye by a tiny, consistent amount. After surgery the average pressure fall was large and the eye shortened measurably. Predicted vision errors differed between the two standard formulas tested. Applying a length correction for pressure cases should sharpen the match between planned and actual vision after surgery.
Catalog record
| CREATOR | Yuri Kosaka, Takashi Kojima, Akeno Tamaoki, Yuki Takagi, Ayako Sawaki, Tsuyoshi Nogami, Tatsushi Kaga |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 20542 |
| LICENSE | CC_BY |
| RIGHTS | CC BY |
| SOURCE | PLOS |