Systematic Validation and Atomic Force Microscopy of Non-Covalent Short Oligonucleotide Barcode Microarrays

Michael A. Cook, Chi-Kin Chan, Paul Jorgensen et al. · 2008

Read Systematic Validation and Atomic Force Microscopy of Non-Covalent Short Oligonucleotide Barcode Microarrays by Michael A. Cook, Chi-Kin Chan, Paul Jorgensen et al. (2008) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/plos-pone-0001546.txt.

Introduction

Michael Cook and co-authors wrote a 2008 PLOS ONE methods paper on cheap barcode chips. Barcode arrays let labs track many cell strains at once via short DNA tags. Building such chips by the standard route is costly. The team built chips where tags bind without a fixed bond, at lower cost.

They checked the cheap chips with care, down to force scans of the surface. The chips read the tags as well as the costly kind. A cheaper chip opens pooled strain tests to more labs. It also scales to the huge libraries that gene screens now use.

Catalog record

CREATORMichael A. Cook, Chi-Kin Chan, Paul Jorgensen et al.
YEAR2008
COLLECTIONPAPERS
FORMATTXT
FILE SIZE75 KB
LICENSECreative Commons Attribution License
RIGHTSCC BY
SOURCEPLOS ONE

Source: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0001546

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Systematic Validation and Atomic Force Microscopy of Non-Covalent Short Oligonucleotide Barcode Microarrays Authors: Michael A. Cook, Chi-Kin Chan, Paul Jorgensen, Troy Ketela, Daniel So, Mike Tyers, Chi-Yip Ho Published: 2008, PLOS ONE DOI: 10.1371/journal.pone.0001546 ABSTRACT Molecular barcode arrays provide a powerful means to analyze cellular phenotypes in parallel through detection of short (20–60 base) unique sequence tags, or “barcodes”, associated with each strain or clone in a collection. However, costs of current methods for microarray construction, whether by in situ oligonucleotide synthesis or ex situ coupling of modified oligonucleotides to the slide surface are often prohibitive to large-scale analyses. Here we demonstrate that unmodified 20mer oligonucleotide probes printed on conventional surfaces show comparable hybridization signals to covalently linked 5′-amino-modified probes. As a test case, we undertook systematic cell size analysis of the budding yeast Saccharomyces cerevisiae genome-wide deletion collection by size separation of the deletion pool followed by determination of strain abundance in size fractions by barcode arrays. We demonstrate that the properties of a 13K unique feature spotted 20 mer oligonucleotide barcode microarray compare favorably with an analogous covalently-linked oligonucleotide array. Further, cell size profiles obtained with the size selection/barcode array approach recapitulate previous cell size measurements of individual deletion strains. Finally, through atomic force microscopy (AFM), we characterize the mechanism of hybridization to unmodified barcode probes on the slide surface. These studies push the lower limit of probe size in genome-scale unmodified oligonucleotide microarray construction and demonstrate a versatile, cost-effective and reliable method for molecular barcode analysis. INTRODUCTION DNA microarray technology has become a standard component in the toolbox of molecular biology. Microarrays have been applied to genome-wide analysis of gene expression, location of transcription factor binding sites (chromatin immunoprecipitation on microarray chip, ChIP-chip), DNA replication fork progression, sister chromatid cohesion, and nucleosome phasing [1] – [5] . More recently, molecular barcode arrays have been used for phenotypic profiling, drug sensitivity and systematic synthetic lethal analysis [6] – [12] . These microarray-based methods facilitate the prediction and definition of gene function, and have broad application in drug discovery and development. Microarray technology relies on the hybridization of a labeled target sequence to a complementary cDNA or oligonucleotide probe immobilized on a glass surface. The method of deposition and immobilization varies depending upon the average length of the probe. For cDNA and long oligonucleotide sequences, probes produced ex situ are typically spotted onto a positively charged surface, such as poly-lysine or amino-silane, and are immobilized through UV cross-linking [13] – [15] . Covalent bond formation is thought to occur primarily through thymine bases in the DNA probes [16] , [17] . However, in the case of shorter oligonucleotides (15–60 mer), which possess a smaller complementary sequence over which to bind their cognate targets, probes are commonly synthesized with a 5′-chemically reactive linker [18] . The linker serves to introduce physical distance between the probe and the glass surface, thereby reducing steric hindrance during hybridization, and to allow covalent coupling of the probe to the derivatized surface of a slide via its reactive thiol or amino group, rather than an internal nucleotide base. In a more sophisticated approach, probes can be synthesized in situ on the array surface using ink-jet or light-directed oligonucleotide synthesizers, thereby bypassing the need for a secondary linkage reaction [19] , [20] . The complications of in situ synthesis or ex situ derivatization of oligonucleotides add considerable expense to the fabrication process, particularly when hundreds of high-density microarrays are required. To ameliorate the cost of array fabrication, small unmodified oligonucleotides have been successfully spotted on conventional surfaces [13] , [21] , [22] or on surfaces modified for better adsorption of molecules [23] on both trial and genome-wide scales [23] , [24] . However, under commonly used hybridization conditions, as probe size is reduced below ∼40 bases, hybridization efficiencies have been shown to drop precipitously [13] , [21] . Recent small-scale application of reactive poly-carbodiimide surface substrates has enabled use of the smallest yet unmodified oligonucleotide probes (10–12 mer) [25] , [26] ; however, the performance of this system on a genome-wide scale, with the corresponding large dynamic range of target abundances, hybridization efficiencies, and probe sequence compositions has yet to be ascertained. Rather than applying newly introduced microarray surface substrates, we optimized a method to spot and hybridize unmodified short 20 mer oligonucleotide probes on conventional amino-silane based microarray surfaces. We applied the method to construct a 12,683 unique feature array that is complementary to the barcode tags of the budding yeast deletion strain collection. This collection, constructed by an international consortium, is composed of ∼6000 individual yeast strains that bear precise null deletions of each known or predicted open reading frame (ORFs) [27] . Each deletion construct in the collection is flanked by two 56 bp cassettes, which are comprised of universal primer sequences flanking a unique 20 mer DNA sequence identifier referred to as a barcode. The barcode tags enable genome-wide profiles of pooled populations to be assessed in a single experiment. In a typical experiment, DNA is extracted from the pooled population before and after selection, barcode sequences are amplified and differentially labeled, and the degree of enrichment or depletion of each strain in the selected population is determined by barcode microarray analysis. Here, we demonstrate that short unmodified oligonucleotide probes spotted on Corning GAPS™II slides yield comparable signal intensities and signal-to-noise ratios (SNRs) to 5′-amino-modified covalently linked oligonucleotides. In a proof-of-concept application, we use a 13K feature barcode microarray to analyze the size distribution of the entire yeast deletion collection in a single experiment. By direct comparison of these experiments with previously obtained genome-scale cell size data [28] , we provide rigorous biological validation of our unmodified oligonucleotide arrays and of the barcode approach to cell size determination. Further, as part of our analyses, we outline methodology to minimize false discovery and to define significant enrichment. We demonstrate that data obtained from short unmodified oligonucleotide arrays, while not equally precise as that obtained using inkjet-synthesized Agilent barcode arrays, are nonetheless specific, and as biologically accurate and comprehensive. Lastly, we use atomic force microscopy (AFM) to examine the arrangement of spotted 20 mer oligonucleotides, both before and after binding of their cognate target sequences. Through this we provide evidence as to the mechanism of target hybridization to unmodified oligonucleotide probes at a molecular level. The properties of short unmodified oligonucleotide arrays provide a considerable cost-saving alternative in barcode or short oligonucleotide DNA microarray fabrication, particularly amenable to large-scale in-house synthesis efforts (in our case, forgoing oligonucleotide modification confers an approximately 75% savings in synthesis costs; Supplementary Table S1 ). The savings imparted can, in turn, be passed on to other laboratories, providing greater access to barcode microarray technology. RESULTS Prior to constructing whole genome yeast barcode arrays, we compared performance of arrays prepared by different methods. We designed a pilot array containing 5′-amino modified 20 mer probes for both UP and DOWN (hereafter “DN”) tags of 92 non-essential open reading frames (ORFs) from chromosome 2 (total of 184 unique probe sequences). To assess the effect of the 5′ modification reaction, we compared the hybridization properties of eight control probes lacking the 5′-modification versus their modified counterparts on two substrates that did or did

Read the complete text