Diminiode performance data with an ASTAR-811C emitter and a niobium - 1-percent-zirconium collector

Unknown · 2013

Read Diminiode performance data with an ASTAR-811C emitter and a niobium - 1-percent-zirconium collector by Unknown (2013) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/nasa-tm-19720022951-diminiode-performance-data-with-an-astar.txt.

Introduction

Arthur L Smith, Richard B Lancashire, Eugene J Manista, and James F Morris of the Lewis Research Center mapped this tiny power device in September 1972, as NASA TM X-2587. The device is a diminiode, a miniature thermionic diode that turns heat into current. Its emitter was a tantalum alloy called ASTAR-811C. The collector used niobium with one percent zirconium. A guarded collector kept the readings clean at the edges.

A computerized facility swept and recorded the performance map. The gap between the hot emitter and collector stayed fixed. It measured only a quarter of a millimeter across the flat faces. Such small diodes served as test vehicles for bigger converters. Their maps showed how new electrode materials behaved. The work continued a long Lewis program in thermionic power.

Catalog record

CREATORUnknown
YEAR2013
COLLECTIONPAPERS
FORMATTXT
FILE SIZE19 KB
LICENSEPublic Domain
RIGHTSPUBLIC DOMAIN
SOURCENASA NTRS

Source: https://ntrs.nasa.gov/citations/19720022951

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Diminiode performance data with an ASTAR-811C emitter and a niobium - 1-percent-zirconium collector NASA Technical Memorandum NASA T EfTH N I C A L NASA TM X-25SJ E IVIORANDU M CO DIMINIODE PERFORMANCE DATA WITH AN liTAR-81lC EMITTER AND A NIOBIUM - t PERCENT-ZIRCONIUM COLLECTOR Arthur L* Smith, Richard B. Lancashire, Eugene J. Manista, and James F. Morris Lewis Research Center I] Cleveland, Ohio 44135 ..,, ... • , ,. ,-: ; NATIONAL AERONAUTICS AND SPACE ADMINISTRATION - WASHINGTON, 0. C. • SEPTEMBER Wf2 1. Report No. 2. Government Accession No. 3. Recipient's Catalog No. NASA TM X-2587 4. Title and Subtitle 5. Report Date DIMINIODE PERFORMANCE DATA WITH AN ASTAR-811C September 1972 EMITTER AND A NIOBIUM - 1-PERCENT-ZIRCONIUM 6. Performing Organization Code COLLECTOR .7. Author(s) 8. Performing Organization Report No. Arthur L. Smith, Richard B. Lancashire, Eugene J. Manista, E-6962 and James F. Morris 10. Work Unit No. 9. Performing Organization Name and Address 112-27 Lewis Research Center 11. Contract or Grant No. National Aeronautics and Space Administration Cleveland, Ohio 44135 13. Type of Report and Period Covered 12. Sponsoring Agency Name and Address Technical Memorandum National Aeronautics and Space Administration 14. Sponsoring Agency Code Washington, D.C. 20546 ELECTRODE PREPARATION Emitter The ASTAR-811C material used conformed to the specifications of NAS-10200. After grinding the surface flat, the emitter was cleaned in the following solution (vol %) for 30 seconds prior to converter assembly: 5 FH, 10 HNO3, 15 H2SO4, and 70 H2O. Collector The surface of the Nb - IZr collector and guard ring were machined to a finish of about (64 juin.) and then ground flat and parallel to each other. The pieces were then cleaned in a solution of trichlorethylene prior to converter assembly. TEST FACILITY Test Station A photograph of the mockup of the planar, guarded, miniaturized converter is shown in figure 1. The interelectrode spacing of 0. 254 millimeter was determined from refer- ence surfaces on the emitter and collector body. The diminiode attached to a mounting flange is shown in figure 2. The converter, which was fabricated, processed, and filled with cesium by the procedure discussed in reference 2, was mounted in one of six vacuum test stands that are coupled to a central instrumentation control panel (ref. 3). Each sta- tion has its own set of emitter, collector, and cesium-reservoir heat supplies. Thermal balances of the collector and reservoir are achieved through gaseous nitrogen cooling. A schematic diagram of the diminiode thermionic converter is shown in figure 3. Instrumentation The current developed in the converter was measured by the voltage drop across either a 0.1 or 1.0 ohm, low-inductance, precision shunt. The output voltage was meas- ured using the sheaths of the cesium reservoir and collector thermocouples as potential probes. The 0. 16-square-centimeter collector face determined the current density. The guard ring current lead was electrically connected to the loading circuit so as not to contribute current through the collector current shunt. Collector and cesium-reservoir temperatures were sensed by sheathed chromel- alumel thermocouples. The couples were continuous and were brought through the vac- uum wall of the test station into a common ambient cold junction zone. The temperature of the ambient zone was sensed by a chromel-alumel couple that was referenced elec- tronically to 273 K. Two couples were inserted at each location. The cesium reservoir couples were in the tantalum block surrounding the tantalum tube containing the cesium (see fig. 3). The collector couple was within 5 millimeters of the collector surface. An automatic optical pyrometer monitored the emitter temperature and provided the emitter temperature trigger input to the data system. An automatic optical pyrometer monitored the outside blackbody hole temperature during the performance mapping tests. This temperature was related to the inner blackbody temperature, representative of emitter surface temperature, during processing. A manually balanced, disappearing filament pyrometer was used to observe the two cavities during the calibration phase. The optical path and pyrometer were calibrated against a National Bureau of Stand- ards (NBS) tungsten strip lamp. The maximum uncertainty associated with the observed temperature is approximately ±10 K. This estimate includes the accuracy of the NBS calibration, the reversal capabilities of the optical pyrometer, and the effect of the ap- proximate blackbody cavity in the emitter. The calibration data indicated that an insignificant change in the two cavity temper - atures occurred as the collector temperature was varied over its nominal operating range of 750 to 1100 K. Electron cooling and heating effects on the surface temperatures are negligible since the time interval over which the load is applied is very short and the converter is held at a low-current, retarded-voltage condition between tests (ref. 1). The contribution of gaseous conduction is negligible. Test Procedure The computer-controlled data acquisition system is programmed to monitor the emit- ter and cesium reservoir temperature and to trigger the variable load whenever these in- puts fall within prescribed limits. For the data presented herein, a single sweep of the cur rent-voltage characteristic at fixed emitter, collector, and cesium reservoir temperatures was used. The detailed operation of the system is described in references 1 and 4. Preliminary investigations were conducted to determine the effect of emitter, col- lector, and cesium temperature on performance. Results obtained indicated that high performance could not be achieved by any grouping of temperatures investigated. Con- sequently, the scope of the test program was reduced accordingly, and only a limited amount of accumulated data are presented. Data Presentation Table I lists the temperature conditions for the data presented herein. As shown, the data were taken at an emitter of 1800 K, a collector of approximately 1040 K, and a cesium reservoir range of 604 to 708 K. TABLE I. - TEMPERATURE CONDITIONS FOR COMPUTER- PROCESSED PLOTS [Emitter temperature, Tg, 1800 K.] Collector Cesium reservoir temperature, temperature, TE> T c' K K 1039 604 1037 615 1041 627 1043 641 1042 651 1041 663 1044 676 1043 686 1043 699 1045 708 . The Lewis central computer sorts the diode test data and displays them on separate J, V and P, V plots, as well as composites on the microfilm output. The individual J, V and P,V curves are presented in figures 4(a) to (j). The curves, as presented, are the direct output from the computer. The square symbols indicate a change in voltage from right to left; the round symbols are from left to right. Figure 5 summarizes the J,V data for all reservoir temperatures for the selected emitter and collector temperatures. The current density increases with increases in reservoir temperature up to 651 K. Beyond this value an additional increase in reservoir temperature results in a reduction in current density and output power. The results of the testing show that the maximum power output of the ASTAR-811C Nb-lZr electrode combination was 2. 5 watts per square centimeter. This level of per- formance might be acceptable depending on the total integrated system requirement. The observed performance of the alloyed electrodes probably will vary with time as the chem- ical composition of the surface becomes contaminated due to diffusion of material from the bulk. This process was not investigated during the accumulated testing time of ap- proximately 30 hours. Finally, at the collector

Read the complete text