Read Clinical and analytical validation of FoundationOne Liquid CDx, a novel 324-Gene cfDNA-based comprehensive genomic profiling assay for cancers of solid tumor origin. by Woodhouse R, Li M, Hughes J, Delfosse D, Skoletsky J, Ma P, Meng W, Dewal N, Milbury C, Clark T, Donahue A, Stover D, Kennedy M, Dacpano-Komansky J, Burns C, Vietz C, Alexander B, Hegde P, Dennis L. (2020) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc7518588.txt.

Introduction

Woodhouse and co-authors validate FoundationOne Liquid CDx, a blood-based genomic profiling test for solid tumors. The assay reads cell-free DNA shed into the blood. It promises a match to tissue testing as precision therapies expand.

Validation covered more than 7,500 tests and 30,000 unique variants. The panel spans 324 genes across more than 30 cancer types in the studies. The false positive variant rate was about 1 in 8,000 in the validation runs. Variant calling matched an orthogonal method closely overall. The test also gauges complex markers such as microsatellite instability and blood tumor mutational burden. The authors present clinical validity across multiple tumor types. They back the assay as a complement to tissue testing in the clinic.

Catalog record

CREATORWoodhouse R, Li M, Hughes J, Delfosse D, Skoletsky J, Ma P, Meng W, Dewal N, Milbury C, Clark T, Donahue A, Stover D, Kennedy M, Dacpano-Komansky J, Burns C, Vietz C, Alexander B, Hegde P, Dennis L.
YEAR2020
COLLECTIONPAPERS
FORMATTXT
FILE SIZE54 KB
LICENSECC BY 4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/articles/PMC7518588

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Clinical and analytical validation of FoundationOne Liquid CDx, a novel 324-Gene cfDNA-based comprehensive genomic profiling assay for cancers of solid tumor origin By Ryan Woodhouse, Meijuan Li, Jason Hughes, David Delfosse, Joel Skoletsky, Pei Ma, Wei Meng, Ninad Dewal, Coren Milbury, Travis Clark, Amy Donahue, Dan Stover Published in: PLoS ONE DOI: 10.1371/journal.pone.0237802 ABSTRACT Abstract As availability of precision therapies expands, a well-validated circulating cell-free DNA (cfDNA)-based comprehensive genomic profiling assay has the potential to provide considerable value as a complement to tissue-based testing to ensure potentially life-extending therapies are administered to patients most likely to benefit. Additional data supporting the clinical validity of cfDNA-based testing is necessary to inform optimal use of these assays in the clinic. The FoundationOne®Liquid CDx assay is a pan-cancer cfDNA-based comprehensive genomic profiling assay that was recently approved by FDA. Validation studies included >7,500 tests and >30,000 unique variants across >300 genes and >30 cancer types. Clinical validity results across multiple tumor types are presented. Additionally, results demonstrated a 95% limit of detection of 0.40% variant allele fraction for select substitutions and insertions/deletions, 0.37% variant allele fraction for select rearrangements, 21.7% tumor fraction for copy number amplifications, and 30.4% TF for copy number losses. The limit of detection for microsatellite instability and blood tumor mutational burden were also determined. The false positive variant rate was 0.013% (approximately 1 in 8,000). Reproducibility of variant calling was 99.59%. In comparison with an orthogonal method, an overall positive percent agreement of 96.3% and negative percent agreement of >99.9% was observed. These study results demonstrate that FoundationOne Liquid CDx accurately and reproducibly detects the major types of genomic alterations in addition to complex biomarkers such as microsatellite instability, blood tumor mutational burden, and tumor fraction. Critically, clinical validity data is presented across multiple cancer types. INTRODUCTION As availability of precision therapies expands [1], there is an increasing reliance on genomic profiling assays to help identify the most relevant treatment options for advanced cancer patients [2–4]. Comprehensive genomic profiling (CGP) utilizes next generation sequencing (NGS) technology to examine entire exonic regions of cancer-relevant genes (in contrast to limited “hot spot” tests) for all tumor types, identifying the 4 main classes of genomic alterations: base substitutions (subs), insertions or deletions (indels), copy number alterations (CNAs), and gene rearrangements. Further, CGP assays can assess genomic alteration patterns across related genes in established cancer pathways to report complex biomarkers such as blood tumor mutational burden (bTMB) and microsatellite instability (MSI) to inform cancer treatment decisions using a single assay. Historically, CGP has utilized tumor tissue, although evaluable tumor tissue is not available for many patients [5–9]. with 38% of stage IV non-small cell lung cancer (NSCLC) patients in one single-center cohort study having insufficient quantity or quality of DNA for NGS. [7]. Often referred to as liquid biopsy assays, circulating cell-free DNA (cfDNA)-based assays, are a growing method for providing genomic profiling results to patients. There are a number of reasons that a liquid biopsy may be chosen in the clinical setting. For example, cfDNA-based testing is established for patients who are unable to provide evaluable tissue or when tissue quality or quantity is insufficient in a number of cancers [10–13]. Liquid biopsy assays may also offer a reduced time from sample to result as compared to tumor tissue assays due to the time required to provide a tumor sample for testing [14,15]. Additionally, due to intratumor heterogeneity, a tumor biopsy may represent a small sample of the overall tumor cell population, a limitation that can potentially be overcome with liquid biopsy [10, 16–18]. Tissue-based CGP has been shown to have improved clinical value compared to non-CGP testing, and liquid testing will likely add value based on its ability to find complementary information and provide biomarker results for patients unable to receive tissue testing [19]. Analytical validity of an NGS assay refers to how well the test identifies a particular genetic characteristic, such as a genomic alteration or genomic signature [20]. Analytical validation is important to demonstrate that a test accurately and reliably detects genomic alterations present in a sample. Clinical validity refers to the relationship between a genomic variant and the presence or absence of a specific disease, while clinical utility refers to the correlation of test results with improved health outcomes [20]. Clinical validation is critical to evaluate the correlation of test results with health outcomes. The US FDA requires robust analytical and clinical validation, above and beyond the validation standards set by Clinical Laboratory Improvement Amendments (CLIA), prior to approval or clearance of a diagnostic device [21]. Liquid biopsy assays may be clinically valuable [10–13] but can be technically challenging. Although there is an increasing use of liquid biopsies in clinical practice, additional clinical validity and utility data is still needed [22]. Many studies assessing the analytical validity of liquid biopsy assays examine concordance between tumor tissue and plasma samples, which introduces confounding variables such as tumor heterogeneity and has the potential to conflate clinical validity with analytical validity [22]. These challenges can be overcome by evaluating analytical validity using samples with known variants at specified variant allele fractions such as cell line DNA diluted in an appropriate matrix [22]. Additionally, an evaluation of the potential impact of preanalytical and analytical variables is crucial [22]. The analyses presented here describe the broad analytical and clinical validation of FoundationOne®Liquid CDx (Foundation Medicine, Inc; Cambridge, MA), a novel liquid biopsy CGP platform. The validation of tumor fraction (TF), variant allele fraction (VAF), and other clinical validation studies will be described in detail elsewhere. MATERIALS AND METHODS Assay methods FoundationOne Liquid CDx is an FDA-approved next generation sequencing-based in vitro diagnostic device that targets 324 genes utilizing circulating cell-free DNA (cfDNA) isolated from plasma derived from the anti-coagulated peripheral whole blood of cancer patients, performed at Foundation Medicine, Inc (Cambridge, MA) (link to the FDA label [23]). Additional clinical decision insights and genomic analysis are also provided as a professional service under CLIA and College of American Pathologists (CAP) regulations. This assay is the result of the evolution of Foundation Medicine’s FoundationACT and FoundationOne Liquid assays. All coding exons of 309 genes are targeted; select intronic or non-coding regions are targeted in 21 of these genes. Additionally, select intronic or non-coding regions are targeted in 15 genes, resulting in 324 total targeted genes. Sequence data are processed using a custom analysis pipeline that filters sequencing artifacts and variants known to be benign. Known and likely pathogenic variants implicated in cancer are reported, which may be somatic and/or germline variants. The assay detects substitutions, indels, genomic rearrangements, CNAs (amplifications and losses), and genomic signatures including bTMB, MSI, and TF. Through a novel hybrid capture approach, a subset of targeted regions in 75 genes is baited for greater sensitivity through ultra-deep sequencing coverage (referred to as the enhanced sensitivity region). The enhanced sensitivity region was selected based on genomic regions with increased actionability with current or future targeted therapies (Fig 1). Other targeted genomic regions are baited for high sensitivity through deep sequencing coverage (referred to as the standard sensitivity region). Refer to S1 Table for the complete list of targeted genes. [Figure: FoundationOne Liquid CDx assay utilization overview.FoundationOne Liquid CDx was designed to

Read the complete text