Aerosol and surface contamination of SARS-CoV-2 observed in quarantine and isolation care.
Santarpia JL, Rivera DN, Herrera VL, Morwitzer MJ, Creager HM, Santarpia GW, Crown KK, Brett-Major DM, Schnaubelt ER, Broadhurst MJ, Lawler JV, Reid SP, Lowe JJ. · 2020
Read Aerosol and surface contamination of SARS-CoV-2 observed in quarantine and isolation care. by Santarpia JL, Rivera DN, Herrera VL, Morwitzer MJ, Creager HM, Santarpia GW, Crown KK, Brett-Major DM, Schnaubelt ER, Broadhurst MJ, Lawler JV, Reid SP, Lowe JJ. (2020) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc7391640.txt.
Introduction
Santarpia and co-authors sampled the air and surfaces around isolated COVID-19 patients in Scientific Reports. Transmission routes were disputed early on, and guidelines swung between droplet and airborne precautions. During the initial isolation of 13 patients at the University of Nebraska Medical Center, the team collected air and surface specimens.
Viral contamination turned up across the samples, in air as well as on surfaces, even beyond the patients' immediate surroundings. The pattern supports treating shed virus as an airborne risk during care, not only a touch risk. The authors back airborne isolation precautions for staff treating such patients. Readers get direct environmental evidence from a specialist unit, gathered when almost none existed.
Catalog record
| CREATOR | Santarpia JL, Rivera DN, Herrera VL, Morwitzer MJ, Creager HM, Santarpia GW, Crown KK, Brett-Major DM, Schnaubelt ER, Broadhurst MJ, Lawler JV, Reid SP, Lowe JJ. |
|---|---|
| YEAR | 2020 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 34 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Aerosol and surface contamination of SARS-CoV-2 observed in quarantine and isolation care By Joshua L Santarpia, Danielle N Rivera, Vicki L Herrera, M Jane Morwitzer, Hannah M Creager, George W Santarpia, Kevin K Crown, David M Brett-Major, Elizabeth R Schnaubelt, M Jana Broadhurst, James V Lawler, St Patrick Reid Published in: Scientific Reports DOI: 10.1038/s41598-020-69286-3 ABSTRACT Abstract The novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) originated in Wuhan, China in late 2019, and its resulting coronavirus disease, COVID-19, was declared a pandemic by the World Health Organization on March 11, 2020. The rapid global spread of COVID-19 represents perhaps the most significant public health emergency in a century. As the pandemic progressed, a continued paucity of evidence on routes of SARS-CoV-2 transmission has resulted in shifting infection prevention and control guidelines between classically-defined airborne and droplet precautions. During the initial isolation of 13 individuals with COVID-19 at the University of Nebraska Medical Center, we collected air and surface samples to examine viral shedding from isolated individuals. We detected viral contamination among all samples, supporting the use of airborne isolation precautions when caring for COVID-19 patients. Subject terms: Diseases, Infectious diseases, Viral infection INTRODUCTION Healthcare worker protection and effective public health measures for emerging infectious diseases require guidance based upon a solid understanding of modes of transmission. Scant evidence describing SARS-CoV-21 transmission dynamics has led to shifting isolation guidelines from the WHO, U.S. CDC and other public health authorities. Evidence suggests that other emerging coronavirus diseases (e.g. SARS and MERS) have airborne transmission potential2,3 in addition to more direct contact and droplet transmission. At least one study suggests that MERS-CoV has the possibility of transmission from mildly ill or asymptomatic individuals4. Surface samples taken in patient care areas for MERS-CoV and SARS-CoV have shown positive PCR results3; however, experts question the presence of viable virus and the implication for transmission through fomites contaminated by the direct contact of the infected person or the settling of virus-laden particles onto the surface5. Nonetheless, nosocomial outbreaks suggest transmission of coronaviruses via environmental contamination6,7. While nosocomial transmission of SARS-CoV-2 is reported, the role of aerosol transmission and environmental contamination remains unclear, and infection preventionists require further data to inform appropriate practices8. The University of Nebraska Medical Center (UNMC), with its clinical partner Nebraska Medicine, cared for 13 individuals with confirmed SARS-CoV-2 infection evacuated from the Diamond Princess cruise ship as of March 6th, 2020. Patients requiring hospital care were managed in the Nebraska Biocontainment Unit (NBU), and mildly ill individuals were isolated in the National Quarantine Unit (NQU), both located on the medical center campus. Key features of the NBU and NQU include: (1) individual rooms with private bathrooms; (2) negative-pressure rooms (> 12 ACH) and negative-pressure hallways; (3) key-card access control; (4) unit-specific infection prevention and control (IPC) protocols including hand hygiene and changing of gloves between rooms; and (5) personal protective equipment (PPE) for staff that included contact and aerosol protection9. RESULTS We initiated an ongoing study of environmental contamination obtaining surface and air samples in 2 NBU hospital and 9 NQU residential isolation rooms housing individuals testing positive for SARS-CoV-2. Samples were obtained in the NQU on days 5–9 of occupancy and in the NBU on day 10. Additional samples were obtained in the NBU on day 18, after Patient 3 had been admitted to the unit for four days. We obtained surface samples, high-volume [50 L/min (Lpm)] air samples, and low-volume (4 Lpm) personal air samples. The surface samples came from common room surfaces, personal items, and toilets. Personal air sampling devices were worn by study personnel on two days during sampling of NBU and NQU rooms. During the sampling, individuals in isolation were recording symptoms and oral temperatures twice a day. The maximum temperature, during the three days preceding sampling, was recorded, as was the presence of any symptoms. During this time, 57.9% of patients recorded a temperature greater than 37.2 °C (99.0 °F), and 15.8% had a temperature greater than 37.8 C (100 °F). Independent of temperature, 57.9% of patients reported other symptoms, primarily cough. Surface and aerosol samples were analyzed by RT-PCR targeting the E gene of SARS-CoV-210. Of the 163 samples collected in this study, 121 (72.4%) had a positive PCR result for SARS-CoV-2. Due to the need to cause minimal disruption to individuals in isolation and undergoing hospital care, the precise surface area sampled in this study was not uniform, so results are presented as concentration of gene copies present in the recovered liquid sample (copies/µL). Viral gene copy concentrations recovered from each sample type were generally low and highly variable from sample to sample ranging from 0 to 1.75 copies/µL (Fig. 1A, and Tables S1 and S2), with the highest concentration recovered from an air handling grate in the NBU. Both the sampling time and flow rate were known for all aerosol samples collected in this study, therefore the airborne concentration was calculated for all air samples (copies/L of air; Tables S1 and S2). [Figure: A Box and whisker plot demonstrating the max and min (whiskers), median (line) and 25th and 75th percentile gene copy concentrations (copies/µL) for all types of samples collected in this study. Data is presented as a concentration in recovered buffer (sterile PBS) for each sample. Surface samples were in a total of 18 mL (3 mL to pre-moisten and 15 mL to recover), bedroom air and hallway air samples were recovered in 15 mL total, while personal air samples were recovered in 10 mL of sterile PBS. B Percentage of positive samples recovered in each room sampling. Bar patterns from the same room and same individual on multiple dates are identical.] Overall, 70.6% of all personal items sampled were determined to be positive for SARS-CoV-2 by PCR (Fig. 1B and Table S1). Of these samples, 75.0% of the miscellaneous personal items (described in the “Methods” section) were positive by PCR, with a mean concentration of 0.22 copies/µL. Samples of cellular phones were 77.8% positive for viral RNA (0.17 copies/µL mean concentration) and remote controls for in-room televisions were 55.6% percent positive (mean of 0.22 copies/µL). Samples of the toilets in the room were 81.0% positive, with a mean concentration of 0.25 copies/µL. Of all room surfaces sampled (Fig. 1B and Table S1), 75.0% were positive for SARS-CoV-2 RNA. 70.8% of the bedside tables and bed rails indicated the presence of viral RNA (mean concentration 0.26 copies/µL), as did 72.7% of the window ledges (mean concentration 0.22 copies/µL) sampled in each room. The floor beneath patients’ beds and the ventilation grates in the NBU were also sampled. All five floor samples, as well as 4 of the 5 ventilation grate samples tested positive by RT-PCR, with mean concentrations of 0.45 and 0.82 copies/µL, respectively. Air samples in the rooms and in the hallway spaces (Fig. 1B, and Tables S1 and S2) provide information about airborne viral shedding in these facilities. We found 63.2% of in-room air samples to be positive by RT-PCR (mean concentration 2.42 copies/L of air). In the NBU, for the first two sampling events performed on Day 10, the sampler was placed on the window ledge away from the patient (NBU Room A occupied by Patient 1),