Read Investigating sources of inaccuracy in wearable optical heart rate sensors. by Bent B, Goldstein BA, Kibbe WA, Dunn JP. (2020) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc7010823.txt.

Description

Bent and co-authors test where wearable heart-rate sensors go wrong. Their study appeared in NPJ Digital Medicine. Wrist devices read pulse optically, sensing blood volume changes under the skin. Makers grade their own products, and their methods are rarely public. Suspected error sources include skin tone, movement, and signal mixing.

The team ran consumer and research devices through rest and activity across the full range of skin tones. Skin tone showed no significant effect on accuracy. Devices differed from each other, and activity mattered a lot: average error ran about a third higher during activity than at rest. All devices handled resting and steady raised heart rates reasonably well. They diverged when activity changed, and delays between device and reference signals ranged up to 43 seconds. For researchers and clinicians, the message is to pick devices carefully and distrust readings taken mid-transition.