Read Electrical stimulation as a novel tool for regulating cell behavior in tissue engineering. by Chen C, Bai X, Ding Y, Lee IS. (2019) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc6896676.txt.

Introduction

Chen and co-authors review electrical stimulation in tissue engineering, in Biomaterials Research. Passing mild electric signals through tissue is drawing wide attention. It shows promise for wound healing and for steering cell behaviour in lab-grown tissue. Currents can switch on signalling pathways inside cells and reshape their surroundings. Migration, growth, and specialisation all respond.

The review surveys the materials and devices used to deliver stimulation safely. Conductive, body-friendly scaffolds let engineers combine a physical support with an electrical cue at once. Cells align and migrate toward one pole under a field, a trick for organising regrowth. The authors close with the gaps between striking lab results and clinical use.

Catalog record

CREATORChen C, Bai X, Ding Y, Lee IS.
YEAR2019
COLLECTIONPAPERS
FORMATTXT
FILE SIZE64 KB
LICENSECC BY 4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/articles/PMC6896676

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Electrical stimulation as a novel tool for regulating cell behavior in tissue engineering By Cen Chen, Xue Bai, Yahui Ding, In-Seop Lee Published in: Biomaterials Research DOI: 10.1186/s40824-019-0176-8 ABSTRACT Abstract Recently, electrical stimulation as a physical stimulus draws lots of attention. It shows great potential in disease treatment, wound healing, and mechanism study because of significant experimental performance. Electrical stimulation can activate many intracellular signaling pathways, and influence intracellular microenvironment, as a result, affect cell migration, cell proliferation, and cell differentiation. Electrical stimulation is using in tissue engineering as a novel type of tool in regeneration medicine. Besides, with the advantages of biocompatible conductive materials coming into view, the combination of electrical stimulation with suitable tissue engineered scaffolds can well combine the benefits of both and is ideal for the field of regenerative medicine. In this review, we summarize the various materials and latest technologies to deliver electrical stimulation. The influences of electrical stimulation on cell alignment, migration and its underlying mechanisms are discussed. Then the effect of electrical stimulation on cell proliferation and differentiation are also discussed. Keywords: Electrical stimulation, Tissue engineered materials, Regenerative medicine BACKGROUND Regenerative medicine and tissue engineering are new scientific and technological undertakings of biomedicine that combine aspects of medicine, cell, and molecular biology, materials science and bioengineering, to regenerate, repair or replace tissues or organs [1, 2]. The three key factors of regenerative medicine and tissue engineering include seed cell, scaffold, and stimulating factor [3]. Tissue engineering scaffold could deliver specific cells to the damaged site and as a medium to provide stimuli, with the help of an appropriate structure, similar composition to natural tissue. Scaffold mimic nature tissue’s mechanical properties and desired biological properties, to ensure in vivo support, optimum diffusion of nutrients, and encourage cellular communication [4, 5], which is an indispensable part of tissue engineering. Seed cell include non-stem cells and stem cells. The non-stem cells includes: Schwann cells (SCs), osteoblasts, fibroblast, and endothelial cells (ECs); the stem cells can be divided into two types: (1) adult stem cell: Adipose derived stem cells and muscle derived stem cells; and (2) non-adult stem cell: Embryonic stem cells (ESCs), neural stem cells (NSCs) and bone mesenchymal stem cells (BMSCs) [6]. Stem cells that possess strong self-renewal and multilineage differentiation potential [7], in cases better than non-stem cells. A cell-seeded scaffold is implanted in the patient, and then the cell will produce the new tissue, is the pillars of tissue engineering [8, 9]. Providing seed cell for damaged or lost organs and tissues are the core of tissue engineering [10]. Rapid and complete regeneration of tissue or organs is a very challenging problem because transplanted cells are easily lost in host tissues and have low survival rates [11, 12]. Furthermore, if defective cells migrating to the wound site will lead to a more severe condition [13]. The loss of cellular function at the donor site and uncontrollable differentiation are limitations for the use of stem cell transplantation in regenerative medicine [13–15]. Thus they require the manipulation of cell behavior in vitro and in vivo, including cell proliferation, migration, differentiation, and other cellular processes [16, 17]. The choice of scaffold material, the surface topography of the scaffold, and the additional stimulating factors can manipulate cell behavior [18–21]. To date, several studies have demonstrated that both biochemical and biophysical cues could influence cell behaviors [17, 22, 23]. Different forms of stimulating factors can induce cell proliferation, differentiation, to complete tissue repair, inappropriate ES could cause cell death or no effect [24]. As a result select suitable stimulate factor could maximize the repair effect [25]. Biochemical cues include supplying chemical reagents [26] and performing chemical surface modification on scaffolds [27]. On the one side, adding growth factors, surface-immobilised biosignals, cytokines, and small molecule drugs would be immediately diluted by blood or metabolized by organisms. On the other side, the surface fixation methods of chemical reagents is also not perfect, methods such as silanization or co-precipitation are complexity and low efficiency, requiring more surface treatment to improve connection efficiency [28] and increasing the deposition rate [29]. Biophysical cues involve surface topography, substrate stiffness, compression and stretching, electric or magnetic fields, ultrasound stimulation, and photostimulation [30–34]. Biophysical cues have the advantages of cost-effectiveness, long life, easy to characterize, and high reproducibility, which is facilitated for a large-scale operation. As a biophysical cue, electrical stimulation (ES) has been shown to effectively relieve pain, promote blood circulation, reduce vascular and skeletal muscle tension, and promote reabsorption of edema and joint fluid in the clinic [35]. Also, many studies show that ES could effectively manipulate cell behaviors in vitro and in vivo. For example, Jaatinen et al. [36] demonstrated that the mouse myoblast cell line undergoes dramatic changes in cell morphology, viability, cell structure, and cell adhesion under pulsed monophasic currents. Kumar et al. [37] showed that the cell proliferation and osteogenic differentiation of preosteoblast could favourably be regulated under dynamic electric field conditions. Besides, with the specific parameter of ES, the neurite outgrowth of NSCs could be improved [19], and the differentiation of NSCs could also be matipulated [38]. In the human body, every cell subjected to some form of stimulation, local bioelectrical signals affect cells in a variety of tissues [39]. Indeed, providing ES is a considerable method based on recent research. ES triggers the cells themselves to deliver signals through intrinsic pathways, consequently leads to direct cell activities, including migration, differentiation, and proliferation, etc. Meanwhile, ES can be used synergistically with other techniques, reducing the cost of the whole process, has the potential of alleviating some of the problems that currently prevail in tissue engineering and regenerative medicine [17, 40–42]. Here, we provide an overview of the recent developments of ES in tissue engineering, for better application in regenerative medicine and tissue engineering. The main part of the review is organized into three parts: (1) summarized the conductive materials that can be applied to tissue engineering scaffolds, including types and their advantages and disadvantages. (2) Three methods of providing ES include direct coupling, capacitive coupling, and using an electromagnetic field, and their advantages and disadvantages. (3) The specific regulation of ES on cell behaviors include cell alignment, migration and its underlying mechanisms, proliferation and differentiation. Comprehensively demonstrate the potential that ES has for tissue engineering. Different materials and methods to deliver ES Tissue engineering attempts to imitate the structure and function of the tissues or organs through the use of engineered scaffolds, which optimize the response of cell-biomaterials and mimic the native environment [43]. ES has received considerable attention to influence cellular or tissue behaviors as stimulation factor of tissue engineering [44]. As a bridge to deliver ES, scaffolds need to meet requirements: excellent biocompatibility, prominent electrochemical performance, and no byproduct generation [45]. Materials to deliver electrical stimulation To provide ES for tissue regeneration or functional recovery, a number of materials have been developed to make scaffolds. To date, metallic biomaterials include platinum, and gold is increasingly used in medical applications due to their high mechanical strength, long-term stability, good conductivity, and biocompatibility [46]. However, except noble metals, most metallic materials are easily oxidized, and present weak corrosion resistance [47, 48], the release of metal ion may also cause