Masson GR, Burke JE, Ahn NG, Anand GS, Borchers C, Brier S, Bou-Assaf GM, Engen JR, Englander SW, Faber J, Garlish R, Griffin PR, Gross ML, Guttman M, Hamuro Y, Heck AJR, Houde D, Iacob RE, Jørgensen TJD, Kaltashov IA, Klinman JP, Konermann L, Man P, Mayne L, Pascal BD, Reichmann D, Skehel M, Snijder J, Strutzenberg TS, Underbakke ES, Wagner C, Wales TE, Walters BT, Weis DD, Wilson DJ, Wintrode PL, Zhang Z, Zheng J, Schriemer DC, Rand KD. · 2019

Read Recommendations for performing, interpreting and reporting hydrogen deuterium exchange mass spectrometry (HDX-MS) experiments. by Masson GR, Burke JE, Ahn NG, Anand GS, Borchers C, Brier S, Bou-Assaf GM, Engen JR, Englander SW, Faber J, Garlish R, Griffin PR, Gross ML, Guttman M, Hamuro Y, Heck AJR, Houde D, Iacob RE, Jørgensen TJD, Kaltashov IA, Klinman JP, Konermann L, Man P, Mayne L, Pascal BD, Reichmann D, Skehel M, Snijder J, Strutzenberg TS, Underbakke ES, Wagner C, Wales TE, Walters BT, Weis DD, Wilson DJ, Wintrode PL, Zhang Z, Zheng J, Schriemer DC, Rand KD. (2019) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc6614034.txt.

Introduction

Masson and co-authors set out shared rules for a fast-growing protein method. Their recommendations appear in Nature Methods. Hydrogen deuterium exchange mass spectrometry, or HDX-MS, probes protein shape and motion. It tracks how backbone hydrogens swap with solvent over time. Use of the method has spread fast in recent years.

The guidance grew from talks at the first HDX conference, held in 2017. The authors cover how to run exchange experiments with proper controls. They advise on data analysis, presentation, and interpretation. Small shifts in pH or temperature can bias results, they warn. Careful repeats are needed to judge precision. Shared practice, they argue, will help nonspecialists trust and use the data. The paper states a consensus view for the field to refine.

Catalog record

CREATORMasson GR, Burke JE, Ahn NG, Anand GS, Borchers C, Brier S, Bou-Assaf GM, Engen JR, Englander SW, Faber J, Garlish R, Griffin PR, Gross ML, Guttman M, Hamuro Y, Heck AJR, Houde D, Iacob RE, Jørgensen TJD, Kaltashov IA, Klinman JP, Konermann L, Man P, Mayne L, Pascal BD, Reichmann D, Skehel M, Snijder J, Strutzenberg TS, Underbakke ES, Wagner C, Wales TE, Walters BT, Weis DD, Wilson DJ, Wintrode PL, Zhang Z, Zheng J, Schriemer DC, Rand KD.
YEAR2019
COLLECTIONPAPERS
FORMATTXT
FILE SIZE48 KB
LICENSECC BY 4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/articles/PMC6614034

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Recommendations for performing, interpreting and reporting hydrogen deuterium exchange mass spectrometry (HDX-MS) experiments By Glenn R. Masson, John E. Burke, Natalie G. Ahn, Ganesh S. Anand, Christoph Borchers, Sébastien Brier, George M. Bou-Assaf, John R. Engen, S. Walter Englander, Johan Faber, Rachel Garlish, Patrick R. Griffin Published in: Nature Methods DOI: 10.1038/s41592-019-0459-y ABSTRACT Hydrogen deuterium exchange mass spectrometry (HDX-MS) is a powerful biophysical technique being increasingly applied to a wide variety of problems. As the HDX-MS community continues to grow, adoption of best practices in data collection, analysis, presentation and interpretation will greatly enhance the accessibility of this technique to nonspecialists. Here we provide recommendations arising from community discussions emerging out of the first International Conference on Hydrogen-Exchange Mass Spectrometry (IC-HDX; 2017). It is meant to represent both a consensus viewpoint and an opportunity to stimulate further additions and refinements as the field advances. MAIN Hydrogen deuterium exchange mass spectrometry (HDX-MS) is a powerful technique that can provide insights into protein behavior by serving as a link between structure, conformational dynamics and function1. HDX-MS measures changes in mass associated with the isotopic exchange between amide hydrogens of the protein backbone and its surrounding solvent. The rate of this exchange is dependent on the folded state of the protein and its dynamics (particularly the stability of hydrogen bonding networks) and the intrinsic chemical properties of the underlying amino acid sequence2–4. HDX-MS is a very versatile technique5 and can be used to examine conformations of individual proteins or large protein complexes6, locate protein sites directly or indirectly involved in binding7, probe for allosteric effects8, monitor the folding dynamics of protein domains9, examine intrinsic disorder10 and provide insights into protein–membrane interactions11. Of particular relevance in industry, HDX-MS also excels at epitope mapping and the characterization of biotherapeutics12,13. Measurement of protein HDX dates back to the 1950s14,15, with much of the work in the 1970–1980s using NMR spectroscopy as the method of detection16. Mass spectrometry has been the method of choice for detecting HDX since the 1990s17,18, because it can accommodate large proteins (>100 kDa), accept low concentrations (less than micromolar) and tolerate complex sample matrices19. Additional advances in liquid chromatography (LC)-MS technology and automation have greatly increased the user base for HDX-MS. Data analysis software has progressed markedly20–22, increasing processing speeds by several orders of magnitude over the past ten years. The analysis of large multi-subunit proteins no longer takes weeks or months. A reduced barrier to entry has accompanied these developments, resulting in an explosion in the amount of HDX-MS data being generated. It is not surprising that the number and diversity of studies that use some variant of the HDX-MS method is increasing year over year23–33 (Fig. 1).Fig. 1The wide range of applications for HDX-MS in many protein-folding studies.Clockwise from top left: Hamdi et al.24 localized dehydration and zinc-activated disorder-to-order transitions in abiotic plant stress response proteins using HDX-MS. Baños-Mateos et al.25 demonstrated how HDX-MS can be used in combination with X-ray crystallography and cryo-electron microscopy (cryo-EM) when determining the mechanism of exonuclease activity of DnaE1. Lim et al.26 determined how an increase in temperature alters the Dengue virus capsid structure, resulting in an alteration in antibody-binding mode. Using ETD-HDX/MS/MS, Masson et al.27 discerned the basis of isotype specificity of pharmaceutical compounds by determining single-residue exchange rates. Merkle et al.28 localized the substrate-dependent partial unwinding of transmembrane helices, which facilities substrate translocation using HDX-MS. Lee et al.29 revealed a new allosteric mechanism for interrupting the antiapoptotic binding of MCL-1 to BH3 domains, providing a new avenue for cancer therapy. Shukla et al.30 demonstrated how HDX-MS can provide mechanistic and dynamic detail to cryo-EM structures, and how HDX-MS can aid modeling of X-ray structures within the cryo-EM density. Adams et al.31 illustrated the utility of HDX-MS, used in conjunction with X-ray crystallography and biophysical methods, to reveal how the monoclonal antibody VHH6 contemporaneously interacts with IL-6 and gp80 through a junctional epitope. Rostislavleva et al.32 pushed the limits of HDX-MS with the large lipid kinase VPS34 complex II by both determining the membrane-interacting regions of the lipid kinase and screening nanobodies to facilitate crystallization and subsequent structure determination. By altering the pH of the labelling solution, de Vera et al.33 observed interactions of disordered protein domain on a millisecond timescale by HDX-MS. Producing a deuterium-labeled sample is simple and requires no specialized equipment or chemicals, other than D2O. However, the labeling reaction is highly sensitive to experimental conditions, such as pH and temperature fluctuations, among other factors34. It requires a number of controls and a great amount of care to ensure that the reaction is conducted in a manner that does not bias the results or lead to imprecise measurements. If properly performed, the HDX-MS method is very reproducible7,35,36, but repeated HDX reactions must be conducted to assess the degree of variability caused by external factors. When due care and attention is taken to fully account for all aspects of sample production37, HDX-MS provides reliable insights into protein structure–function properties. HDX-MS data complement other structural biology techniques, such as nuclear magnetic resonance (NMR) spectroscopy38, electron microscopy30,39, native mass spectrometry40,41, molecular dynamics simulation42 and X-ray crystallography43,44, and are often presented alongside these techniques to nonspecialist reviewers. Likewise, scientists who primarily focus on these complementary techniques may, given the attractiveness and accessibility of HDX-MS, choose to embark on HDX-MS experiments themselves. Unfortunately, the simplicity of the experiment does not always translate into simplicity of interpretation, as the exchange mechanism is complex and important experimental information is all too often missing. Incomplete information compromises the ability to interpret published findings of others. To remedy this situation with several community-driven objectives, we aim to (1) develop consensus-based minimum recommendations for conducting HDX-MS experiments, along with the minimum information required for publication of HDX-MS data; (2) provide a resource for reviewers of manuscripts containing HDX-MS data, allowing them to assess the quality of presented data, and to assist editorial staff in establishing acceptable publication criteria; and (3) position the HDX-MS community for the creation of a standardized and curatable data format that allows for archiving datasets for meta-analysis and protein modeling. DEVELOPMENT OF THE RECOMMENDATIONS The recommendations outlined below were initially discussed in May of 2017 during the first International Conference of Hydrogen Deuterium Exchange (IC-HDX) in Gothenberg, Sweden. The many HDX-MS experts present at IC-HDX debated the minimum criteria for HDX-MS experiments and manuscripts, and reached several consensus points. A draft document incorporating the primary elements of this debate was disseminated among the HDX-MS community, through discussion lists and through direct enquiries to experienced HDX-MS users who could not attend the meeting. SCOPE OF THE RECOMMENDATIONS These recommendations are precisely that: recommendations. They represent community-endorsed practices that ensure minimum requirements necessary to accurately conduct an HDX-MS experiment and report its results. Their aim is to be as practicable as possible to promote widespread adoption. Not all HDX-MS experiments need to conform to these recommendations, but in our opinion, any substantial deviation from these guidelines should be explained. Experiments that are purely technical, focusing on the minutiae of exchange behavior, or exchange under extreme conditions may deviate substantially from the recommendations, but these experiments are likely to be conducted by those already expert in the technique, with

Read the complete text