Read Assessment of Body Composition in Health and Disease Using Bioelectrical Impedance Analysis (BIA) and Dual Energy X-Ray Absorptiometry (DXA): A Critical Overview. by Marra M, Sammarco R, De Lorenzo A, Iellamo F, Siervo M, Pietrobelli A, Donini LM, Santarpia L, Cataldi M, Pasanisi F, Contaldo F. (2019) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc6560329.txt.
Introduction
Marra and co-authors critically compare the two workhorse methods for measuring body composition, writing in Contrast Media and Molecular Imaging. Knowing a patient's fat mass and fat-free mass guides nutrition and care, but neither tool is flawless. The review lays out how each works and where each misleads.
Bioelectrical impedance passes a weak current through the body and infers water and tissue from its resistance. It is cheap, portable and safe, yet its accuracy hinges on the right prediction equations and strict measurement routines. DXA scanning is the reference method, splitting bone, fat and lean tissue in one pass. Its costs are price, expertise, and radiation that limits repeat scans. The authors map which patients suit which method, from clinics to hospital beds.
Catalog record
| CREATOR | Marra M, Sammarco R, De Lorenzo A, Iellamo F, Siervo M, Pietrobelli A, Donini LM, Santarpia L, Cataldi M, Pasanisi F, Contaldo F. |
|---|---|
| YEAR | 2019 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 42 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Assessment of Body Composition in Health and Disease Using Bioelectrical Impedance Analysis (BIA) and Dual Energy X-Ray Absorptiometry (DXA): A Critical Overview By Maurizio Marra, Rosa Sammarco, Antonino De Lorenzo, Ferdinando Iellamo, Mario Siervo, Angelo Pietrobelli, Lorenzo Maria Donini, Lidia Santarpia, Mauro Cataldi, Fabrizio Pasanisi, Franco Contaldo Published in: Contrast Media & Molecular Imaging DOI: 10.1155/2019/3548284 ABSTRACT The measurement of body composition (BC) represents a valuable tool to assess nutritional status in health and disease. The most used methods to evaluate BC in the clinical practice are based on bicompartment models and measure, directly or indirectly, fat mass (FM) and fat-free mass (FFM). Bioelectrical impedance analysis (BIA) and dual energy X-ray absorptiometry (DXA) (nowadays considered as the reference technique in clinical practice) are extensively used in epidemiological (mainly BIA) and clinical (mainly DXA) settings to evaluate BC. DXA is primarily used for the measurements of bone mineral content (BMC) and density to assess bone health and diagnose osteoporosis in defined anatomical regions (femur and spine). However, total body DXA scans are used to derive a three-compartment BC model, including BMC, FM, and FFM. Both these methods feature some limitations: the accuracy of BIA measurements is reduced when specific predictive equations and standardized measurement protocols are not utilized whereas the limitations of DXA are the safety of repeated measurements (no more than two body scans per year are currently advised), cost, and technical expertise. This review aims to provide useful insights mostly into the use of BC methods in prevention and clinical practice (ambulatory or bedridden patients). We believe that it will stimulate a discussion on the topic and reinvigorate the crucial role of BC evaluation in diagnostic and clinical investigation protocols. 1. INTRODUCTION The human body comprises more than thirty measurable components [1]. A direct in vivo measurement of body components is currently not possible; consequently, indirect methods and models have been developed to do that. Within this framework, the World Health Organization (WHO) defines “nutritional status” as the condition of the body, resulting from the balance of intake, absorption, and utilization of nutrients interacting with individual physiological and pathological status. The most frequently applied model to evaluate body composition (BC) in clinical practice and epidemiology splits the body into fat mass (FM) and fat-free mass (FFM), i.e., the bicompartmental model. FM indicates the water-free body component; the remaining body components (skeletal muscle, internal organs, and interstitial fat tissue) are included in the FFM. The most accurate methods to measure FM and FFM according to the bicompartment model are densitometry (underwater weighing), hydrometry (deuterium dilution), Echo-MRI, and total body potassium (TBK) counting. However, these methods are characterized by complex measurement protocols and require specialized expertise and costly equipment, making their application in clinical settings limited. Bioimpedance analysis (BIA) is a widely used method to evaluate BC for both epidemiological and clinical purposes; it measures the electrical properties of body tissue and estimates BC parameters as total body water (TBW) and FFM BC parameters (see methods). BIA is a noninvasive, low cost, and reliable method for BC assessment in clinical and nonclinical settings. The basic principle of the BIA technique is that the transit time of a low-voltage electric current through the body depends on BC characteristics [2]. However, this methodology has limitations due to the chemical composition of FFM (i.e., water, proteins, glycogen, and minerals) because of considerable inter- and intraindividual variability as a consequence of changes in FFM occurring with growth, maturation, ageing, and disease states [3]. Dual energy X-ray absorptiometry (DXA) is the current reference method for the assessment of BC, mainly because it provides accurate estimates of bone mineral, fat, and lean soft tissue (the so called three-compartment model) [4]. DXA utilizes low-emission X-rays to measure the attenuation of incident X-ray beams when they pass through body tissues (high attenuation for bone and low attenuation for fat). The assessment of bone health to establish diagnosis of osteoporosis and fracture risk requires DXA for evaluating bone mineral density (BMD) in selected anatomical regions of interest (e.g., spine and femur). In addition, DXA is capable of providing estimates of visceral fat using validated predictive algorithms [5] and furnishes a measure of truncal fat mass, which has been found to be predictive of disease risk [6]. This review aims to summarize the scientific background of BIA and DXA and to furnish a comprehensive overview of their theoretical/technical concepts and application in bedridden and ambulatory patients and the information they can provide on drug pharmacokinetics. 2. ASSESSMENT OF BC BY BIA BIA measures the electrical properties of body tissues and represents a useful approach for estimating body composition parameters such as TBW and FFM. In the bicompartment model, the human body is composed of FFM, which includes, under physiological conditions, the following components: bone mineral content (≈7%), extracellular water (≈29%), intracellular water (≈44%), and visceral protein (=20%). BIA estimation of body composition is based on body fluid volume measurement using BIA resistance value [2, 7, 8]. Bioelectrical impedance, or bioimpedance (Z, Ω), is defined as the opposition of a conductor to the flow of an alternating electrical current applied to it. Bioimpedance varies with tissue composition as well as with the frequency of the applied current. Bioimpedance is a complex parameter derived from the vector relationship between resistance (R, Ω), which arises from intracellular and extracellular fluids, and reactance (Xc, Ω), which is related to the capacitance of the cell membrane [7]. Although the human body is not a uniform cylinder, an empirical relationship can be established between the ratio height2/R (cm2/Ω 50 kHz), defined as bioimpedance index (BI) measured at 50 kHz, and the volume of TBW, approximately 73% of FFM in healthy individuals. Single-Frequency-BIA (SF-BIA), generally at 50 kHz, is passed between surface electrodes placed on hand and foot. Some BIA devices use other electrode placements, such as foot-to-foot or hand-to-hand electrode (Bipedal BIA). Many studies have compared multifrequency hand-to-foot (HF-BIA) and foot-to-foot (FF-BIA) bioimpedance analysis in order to assess differences in FFM values in populations with a wide range of body mass index (BMI) [9, 10] and they found that FF-BIA gives lowest values of FFM in overweight and obese subjects, also if compared with the results of the DXA [11]. In clinical practice, BIA allows monitoring of body fluids (extracellular/intracellular ratio) and therefore patients' nutritional status, in the short time and long time [12, 13]. 2.1. Phase Angle The phase angle, or PA ((R/Xc) × (180/π)), expressed in degrees) reflects the ratio between intra- and extracellular water. It may be affected by nutritional and hydration status [2] (Figure 1). In healthy subjects, PA ranges between 6° and 7° [14], and in athletes it may reach 8.5° [15]. Low PA (<5°) indicates the loss of cellular integrity [16–18]. The PA appears to be a more sensitive indicator of nutritional status compared to impedance since it is closely associated with cellular integrity [19–22]. 2.2. Multifreqency BIA and BIA Spectroscopy BIA can be performed using simultaneously electrical current with different frequencies. The application of more than two frequencies, ranging from low (1 kHz) to high (500 kHz) frequencies, allows the measurement of TBW, FFM, FM, and ICW and ECW compartments. At low frequencies (1–5 kHz), the electric current does not