Comparative analysis of exosome isolation methods using culture supernatant for optimum yield, purity and downstream applications.
Patel GK, Khan MA, Zubair H, Srivastava SK, Khushman M, Singh S, Singh AP. · 2019
Read Comparative analysis of exosome isolation methods using culture supernatant for optimum yield, purity and downstream applications. by Patel GK, Khan MA, Zubair H, Srivastava SK, Khushman M, Singh S, Singh AP. (2019) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc6441044.txt.
Description
Patel and co-authors test four store-bought kits against the classic spin method for pulling exosomes out of cell culture fluid, judging each on yield, purity, and fitness for later work. Exosome research has boomed, but each lab prepares its samples its own way, and results are hard to compare.
The Invitrogen kit gave the most vesicles, yet their sizes spread wide and they held up worst. Mass checks found plastic-like chemical leftovers in the mix. Its exosomes also slowed cell growth, a hint of toxic residue. The other methods kept vesicles under 150 nanometers, stable and with RNA of like quality. The iZON column did let some non-vesicle clumps through. The head-to-head guides labs to pick by what they plan to do next.
Catalog record
| CREATOR | Patel GK, Khan MA, Zubair H, Srivastava SK, Khushman M, Singh S, Singh AP. |
|---|---|
| YEAR | 2019 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 36 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |