Review of bone graft and bone substitutes with an emphasis on fracture surgeries.
Sohn HS, Oh JK. · 2019
Read Review of bone graft and bone substitutes with an emphasis on fracture surgeries. by Sohn HS, Oh JK. (2019) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc6417250.txt.
Introduction
Sohn and Oh review bone grafts and substitutes in Biomaterials Research. A graft from the patient's own bone is still the gold standard. Supply is limited, though, and taking it can harm the donor site.
Synthetic substitutes use minerals like hydroxyapatite and tricalcium phosphate. They offer endless supply and easy storage and sterilization. They are also brittle and resorb at uneven rates. Newer materials aim to coax bone to grow, like demineralized bone matrix. The review compares each option for fracture surgery, where strength and healing both matter. Surgeons gain a clear trade-off table.
Catalog record
| CREATOR | Sohn HS, Oh JK. |
|---|---|
| YEAR | 2019 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 36 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Review of bone graft and bone substitutes with an emphasis on fracture surgeries By Hoon-Sang Sohn, Jong-Keon Oh Published in: Biomaterials Research DOI: 10.1186/s40824-019-0157-y ABSTRACT Background Autogenous bone graft is the gold standard bone graft material. However, due to limitations of supply and morbidity associated with autograft harvest, various bone substitutes have been considered. This article aims to review the properties of the bone graft and various bone substitutes currently available in orthopedic surgery. Main body Synthetic bone substitutes consist of hydroxyapatite, tricalcium phosphate, calcium sulfate, or a combination of these minerals. Synthetic porous substitutes share several advantages over allografts, including unlimited supply, easy sterilization, and storage. However, they also have some disadvantages, such as brittle properties, variable rates of resorption, and poor performance in some clinical conditions. Recently, attention has been drawn to osteoinductive materials, such as demineralized bone matrix and bone morphogenetic proteins. Conclusion Despite tremendous efforts toward developing autograft alternatives, a single ideal bone graft substitute has not been developed. The surgeon should understand the properties of each bone graft substitute to facilitate appropriate selection in each specific clinical situation. BACKGROUND Bone graft procedures have been increasingly used in traumatology, tumor surgery, spine surgery, infection, and revision arthroplasty. In the US, approximately 500,000 bone graft procedures are performed annually [1]. These numbers easily double or triple on a global basis, resulting in a shortage in the availability of donor tissue conventionally used in these bone reconstruction procedures [1]. In terms of bone healing, autogenous bone graft exhibits the best osteogenic potential and is still considered to be a gold standard by many authors. Recently, another source of autogenous cancellous bone from intramedullary canal is developed. The reamer/irrigator/aspirator (RIA) technique was first developed to prepare long bones for intramedullary nail fixation [2, 3]. However, the autogenous bone graft itself is an additional operation, and complications related to bone harvesting have been reported in up to 20.6% of cases [4–7]. Disadvantages of RIA include cortical perforation, eccentric reaming, articular perforation, and intra- and peri-operative fracture [2]. Allograft has several advantages, including easy use, improved safety profiles, time advantages, availability in diverse sizes and shapes, and no donor-site morbidity. For these reasons, it is a typical alternative to autogenous bone. However, in the process of sterilization and storage, the biological and mechanical properties change, which results in loss of osteoinduction and osteogenic capability. With more demands for spinal fusion, revision surgery of arthroplasty, and joint fusion, there is a relative deficiency in allogeneic bone donors. Due to these disadvantages of autogenous bone or allograft, the necessity of bone substitutes is increasing [1]. Bone healing is a multilateral process that requires mechanical stability and revascularization along with osteogenesis, osteoinduction, and osteoconduction. Osteoinduction means that primitive, undifferentiated and pluripotent cells are stimulated to develop into the bone-forming cell lineage [8]. Osteoconduction means that bone grows on a bone surface that permits bone growth on its surface or down into pores, channels or pipes [8]. Accordingly, the most ideal bone substitute should meet such conditions, have no risk of immunological rejection (biocompatible) or disease infection, and achieve incorporation of graft in host bone by gradually being substituted by regenerated bone [8]. It should be well molded into the bony defect within a short time and should be osteoinductive, osteoconductive, and resorbable [9]. In addition, the ideal bone substitute should be thermally nonconductive, sterilizable, and readily available at a reasonable cost [9]. Bone substitutes have a diversity of composition, mechanical strength, and functional biological mechanisms. Since each bone substitute has its own unique advantages and disadvantages, the relationship between various aspects of biological properties and bone healing should be understood. In this review, we will focus on the properties of bone graft and various bone substitutes currently available in orthopedic surgery. Bone graft Allograft Since the autogenous bone graft might lead to complications related to harvesting and its limitation in terms of graft amount from the patient, the allograft has served as an alternative. With the development of donor screening tests, the risk of infection has been minimized [10]. The advantages of bone allograft include no morbidity of the donor-site, unlimited use of material, and availability in mechanical support with various shapes and sizes. Bone allograft is most often preserved by a freeze-drying process and vacuum-packing. However, the concern that the mechanical property of bone allograft weakens and living osteogenic cells are removed in the process of sterilization and storage are disadvantages of the allograft. These processes affect the capacity of bone healing of the allograft and result in loss of osteogenic and osteoinductive function compared with the autogenous graft. Therefore, it is mainly used in osteoconduction by providing some mechanical support. One of the important issues of allogeneic bone is that there is potential infection risks by virus and others agents despite thorough inspection of donors and plasma examination. However, only two cases of HIV infection were reported with a risk rate of 1:1.6 million [11, 12]. Other cases of HBV, HCV and bacterial infections, including Clostridium difficilis, were also reported [13–16]. These types of infection cannot be removed completely even with various types of sterilization methods currently used. The risk of viral infection can be eliminated in freezing or freezing-drying process, which is the most frequently used technique in individual medical institutions [11, 17, 18]. Although a few people stressed that ethylene oxide gas can prevent viral infection, this gas is unable to penetrate cortical bone [19]. Other methods of sterilization, such as an irradiation, hydrochloric acid, and dimethyl sulfoxide, are unable to destroy a retrovirus similar to human immunodeficiency virus and feline leukemia virus [11]. The reason why the bone union rate following incorporation of allograft might be low is because the allograft has no osteogenesis and weak osteoinductivity and the process of sterilization and storage influence osteoconductivity and osteoinductivity [19–21]. Freezing or freeze-drying processes reduce the risk of an immune response of a bone graft after surgery, but sterilization itself weakens the mechanical property of a grafted bone up to approximately 50%. Furthermore, given that a large amount of gamma irradiation or ethylene oxide gas considerably decreases the osteoinductivity of bone graft, the necessity of synthetic bone substitutes has emerged to avoid adverse effects. Allogeneic bone is available in many preparations, including morselized and cancellous, corticocancellous, cortical graft, osteochondral, whole bone segment, and demineralized bone matrix. The integration process of allogeneic bone is similar to that nonvascularized autogenous bone graft normally undergoes, but the size of allograft influences the time of incorporation. This feature is partially related to a lack of cells in the donated region for bone healing and immune reaction arising in the integration process of allogeneic bone [18, 22, 23]. In most clinical cases, allogenic cancellous bone is used to treat the partial bone defect rather than a segmental bone defect or whole-bone defect because allo-cancellous bone has no mechanical stability. Clinically, it is commonly used to reinforce spinal fusion and pack the bone defect in revision arthroplasty in particular. Two well-known types of ossification reactions, intramembranous ossification and the enchondral ossification, occur on the surface of a graft bone. An external callus is created around allogeneic bone with bridging enchondral bone formation, and resorption and creeping