SCoPE-MS: mass spectrometry of single mammalian cells quantifies proteome heterogeneity during cell differentiation.
Budnik B, Levy E, Harmange G, Slavov N. · 2018
Read SCoPE-MS: mass spectrometry of single mammalian cells quantifies proteome heterogeneity during cell differentiation. by Budnik B, Levy E, Harmange G, Slavov N. (2018) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc6196420.txt.
Introduction
Budnik and co-authors present a methods article in Genome Biology on measuring proteins in single cells. Some questions need thousands of proteins counted in one cell at a time. Mass spectrometry normally needs far more material. The team built SCoPE-MS to close that gap.
The method identified distinct human cancer cell types from their protein profiles alone. In differentiating mouse embryonic stem cells it quantified over a thousand proteins per experiment set. Single-cell profiles let the team pull mixed populations apart. Comparing proteins with RNA messages showed much coordination, yet many genes followed distinct rules at the protein level. The tool opens cell-to-cell protein differences to direct study.
Catalog record
| CREATOR | Budnik B, Levy E, Harmange G, Slavov N. |
|---|---|
| YEAR | 2018 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 55 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
SCoPE-MS: mass spectrometry of single mammalian cells quantifies proteome heterogeneity during cell differentiation By Bogdan Budnik, Ezra Levy, Guillaume Harmange, Nikolai Slavov Published in: Genome Biology DOI: 10.1186/s13059-018-1547-5 ABSTRACT Some exciting biological questions require quantifying thousands of proteins in single cells. To achieve this goal, we develop Single Cell ProtEomics by Mass Spectrometry (SCoPE-MS) and validate its ability to identify distinct human cancer cell types based on their proteomes. We use SCoPE-MS to quantify over a thousand proteins in differentiating mouse embryonic stem cells. The single-cell proteomes enable us to deconstruct cell populations and infer protein abundance relationships. Comparison between single-cell proteomes and transcriptomes indicates coordinated mRNA and protein covariation, yet many genes exhibit functionally concerted and distinct regulatory patterns at the mRNA and the protein level. Electronic supplementary material The online version of this article (10.1186/s13059-018-1547-5) contains supplementary material, which is available to authorized users. BACKGROUND Cellular systems, such as tissues, cancers, and cell cultures, consist of a variety of cells with distinct molecular and functional properties. Characterizing such cellular differences is key to understanding normal physiology, combating cancer recurrence, and enhancing targeted stem cell differentiation for regenerative therapies [1–5]; it demands quantifying the proteomes of single cells. However, quantifying proteins in single mammalian cells has remained confined to fluorescent imaging and antibodies. Fluorescent proteins have proved tremendously useful but are limited to quantifying only a few proteins per cell and sometimes introduce artifacts [5, 6]. Multiple antibody-based methods for quantifying proteins in single cells have been recently developed, including CyTOF [7, 8], single-cell Western blots [9], and Proseek Multiplex, an immunoassay readout by PCR [10]. These methods can quantify up to a few dozen endogenous proteins recognized by highly specific cognate antibodies and have enabled exciting research avenues [5]. Still, the throughput and accuracy of antibody-based methods are limited by cellular permeability, molecular crowding, epitope accessibility, and the availability of highly specific antibodies that bind their cognate proteins stoichiometrically [5, 11]. On the other hand, the application of liquid chromatography (LC) and tandem mass spectrometry (MS/MS) to bulk samples comprised of many cells allows for the confident identification and quantification of thousands of proteins [12–18]. To develop approaches that may bring at least some of this power of LC-MS/MS to single mammalian cells, we considered all steps of well-established bulk protocols and how they may be adapted to much more limited samples. We were motivated by the realization that most proteins are present at over 50,000 copies per cell [19, 20] while modern MS instruments have sensitivity to identify and quantify ions present at hundreds of copies [21, 22]. Thus, if we manage to deliver even 1% of the protein copies from a single cell as ions for MS analysis, we may quantify them accurately [22]. Most protocols for bulk LC-MS/MS begin by lysing the cells with detergents or urea [23]. Since these chemicals are incompatible with MS, they have to be removed by cleanup procedures. These cleanup procedures can result in substantial losses of protein, and colleagues have developed advanced methods, such as SP3 [24] and iST [25], that minimize cleanup losses and allow for quantifying thousands of proteins from samples having just a few micrograms of total protein [23, 26]. Indeed, the SP3 method has been successfully used for purifying and quantifying proteins from single human oocytes (∼ 100 μm diameter) [27]. Still, most mammalian cells are smaller (10–15 μm diameter) [19], and we were not confident that we could clean up their cell lysates (having about 500 pg of total protein) without incurring large protein losses. Thus, we sought to obviate cleanup (and therefore eliminate cleanup-related losses) by replacing chemical lysis with mechanical lysis by focused acoustic sonication [23, 28]. Before being ionized and sent for MS analysis, peptides have to be separated [12, 15, 16]. The separation for bulk samples is usually accomplished by nanoliquid chromatography (nLC). To reduce losses due to proteins adhering to the large surface area of nLC columns, low-input samples can also be separated by capillary electrophoresis [29]. We sought to minimize nLC losses by mixing labeled peptides from single cells with labeled carrier peptides so that many of the peptides lost due to nLC adhesion will be carrier peptides rather than single-cell peptides. This strategy deviates from standard protocols for bulk LC-MS/MS. Once injected into an MS instrument, peptide ions need at least two rounds of MS analysis for confident sequence identification [14, 30, 31]. The first MS scan (MS1) determines the mass over charge ratio (M/z) for ions that entered the instrument. Then, selected ions are accumulated and fragmented, and their fragments are analyzed by an MS2 scan [12, 31]. The most commonly used fragmentation methods break peptides at the peptide bonds with efficiency that varies much from bond to bond [31]. Since some fragments are produced with low efficiency, they will not be detected if the peptide ions have low abundance; if not enough fragments are detected, the peptide cannot be sequenced. We sought to alleviate this limitation by sending for MS2 analysis-labeled peptide ions having the same M/z (and thus the same sequence labeled with sample-specific barcodes) from multiple single cells and from carrier cells so that a larger number of peptide ions are fragmented and used for sequence identification. This strategy is built upon the foundational ideas of isobaric tandem mass tags (TMT) [31–33]. TMT labels are used with conventional bulk LC-MS/MS to label samples of equal total protein amount [15, 31, 34] and offer many advantages, albeit quantification can be affected by ion co-isolation [35]; our implementation of TMT, as described below, uses a carrier channel with much higher total protein abundance than the single cells and deviates from the standard protocols. MS instruments have expanding but limited capacity for parallel ion processing and analysis [12, 36, 37]. Thus increase in throughput has been driven in part by decreasing the time for each step, reaching low millisecond ranges for MS scans and for ion accumulation for bulk LC-MS/MS analysis [15, 36]. On the other hand, nLC elution peaks have widths on the order of seconds [22, 28]. Thus, if a peptide elutes from the nLC for 8 s and is accumulated (sampled) for only 50 ms by an MS instrument, the instrument will measure only a small fraction of the peptide molecules in the sample [22]. This inefficient sampling is compensated for in standard bulk methods by the large input amount but becomes problematic for low-input samples; counting noise alone can undermine quantification [22]. In this work, we sought to alleviate the sampling limitation by increasing the ion accumulation (sampling) time at the expense of quantifying fewer peptides per unit time. We have discussed additional strategies for increasing sampling and mitigating its trade-offs in a recent perspective [22]. RESULTS Thus, to develop a high-throughput method for Single Cell ProtEomics by Mass Spectrometry (SCoPE-MS), we had to alter substantially the LC-MS/MS methods for bulk samples. In particular, we had to resolve two major challenges: (i) delivering the proteome of a mammalian cell to a MS instrument with minimal protein losses and (ii) simultaneously identifying and quantifying peptides from single-cell samples. To overcome the first challenge, we manually picked live single cells under a microscope and