Read Estimating sleep parameters using an accelerometer without sleep diary. by van Hees VT, Sabia S, Jones SE, Wood AR, Anderson KN, Kivimäki M, Frayling TM, Pack AI, Bucan M, Trenell MI, Mazzotti DR, Gehrman PR, Singh-Manoux BA, Weedon MN. (2018) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc6113241.txt.

Introduction

van Hees and co-authors present a methods article in Scientific Reports on estimating sleep from a wrist sensor, with no sleep diary. Large population studies now use wrist accelerometers that record raw movement data. Diaries are often missing or unreliable. The team built a simple algorithm to find the sleep period from movement alone.

The method uses changes in the estimated angle of one axis and basic rules about sleep breaks. It was checked against diaries from 3,752 adults aged 60 to 82. It was also checked against lab sleep studies in clinic patients and healthy sleepers. The sensor-based window matched the diary closely. The work helps big studies measure sleep at scale.

Catalog record

CREATORvan Hees VT, Sabia S, Jones SE, Wood AR, Anderson KN, Kivimäki M, Frayling TM, Pack AI, Bucan M, Trenell MI, Mazzotti DR, Gehrman PR, Singh-Manoux BA, Weedon MN.
YEAR2018
COLLECTIONPAPERS
FORMATTXT
FILE SIZE42 KB
LICENSECC BY 4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/articles/PMC6113241

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Estimating sleep parameters using an accelerometer without sleep diary By Vincent Theodoor van Hees, S. Sabia, S. E. Jones, A. R. Wood, K. N. Anderson, M. Kivimäki, T. M. Frayling, A. I. Pack, M. Bucan, M. I. Trenell, Diego R. Mazzotti, P. R. Gehrman Published in: Scientific Reports DOI: 10.1038/s41598-018-31266-z ABSTRACT Wrist worn raw-data accelerometers are used increasingly in large-scale population research. We examined whether sleep parameters can be estimated from these data in the absence of sleep diaries. Our heuristic algorithm uses the variance in estimated z-axis angle and makes basic assumptions about sleep interruptions. Detected sleep period time window (SPT-window) was compared against sleep diary in 3752 participants (range = 60–82 years) and polysomnography in sleep clinic patients (N = 28) and in healthy good sleepers (N = 22). The SPT-window derived from the algorithm was 10.9 and 2.9 minutes longer compared with sleep diary in men and women, respectively. Mean C-statistic to detect the SPT-window compared to polysomnography was 0.86 and 0.83 in clinic-based and healthy sleepers, respectively. We demonstrated the accuracy of our algorithm to detect the SPT-window. The value of this algorithm lies in studies such as UK Biobank where a sleep diary was not used. INTRODUCTION Wrist-worn raw-data accelerometers are increasingly used for the assessment of physical activity in large population studies such as the Whitehall II study or mega-cohorts such as UK Biobank1–3. The decision to use raw-data accelerometers is motivated by the improved comparability of output across different sensor brands4,5, and better control over all steps in data processing6. Accelerometers are commonly worn for 24 hours per day, thus providing information over the day and night; making them potentially valuable for sleep research. A major challenge in accelerometer-based sleep measurement is to derive sleep parameters without additional information from sleep diaries1,3,7. Standard methods for sleep detection based on conventional accelerometers (actigraphy) involves asking the participant to record their time in bed, sleep onset, and waking up time8–10. In a previous paper we developed a method to detect sleep guided by sleep diary records11. However, the increasing use of accelerometry in studies worldwide without sleep diaries necessitates the development of novel methods to derive indicators of sleep behaviour, in the absence of sleep diary records. A crucial step is the detection of the sleep period time window (SPT-window), which is the time window starting at sleep onset and ending when waking up after the last sleep episode of the night. Once the SPT-window can be detected without a diary, our previously published method can be used to detect sleep episodes within this window11. Polysomnography (PSG) is considered the gold-standard measure of sleep parameters, making it an ideal methodology to validate sleep detection methods using an accelerometer. Additionally, experiments in daily life can be used to establish concurrent validity with sleep diary. We aim to develop and evaluate a heuristic algorithm for the detection of the SPT-window from raw data accelerometers unaided by a sleep diary and to compare sleep parameters (waking up, sleep onset time and SPT-window duration) with sleep diary records assessed in the daily life of a large cohort of older adults, and with PSG data collected in a sleep clinic and a group of healthy good sleepers. METHODS Study population In order to assess the validity of our algorithm in different settings and against both data from sleep diary and polysomnography, data are drawn from three different study populations described below. The Whitehall II cohort study12: full details on data collection were previously described11. Briefly, accelerometer measurement was added to the study at the 2012/2013 wave of data collection for participants seen at the central London clinic and for those living in the South-Eastern regions of England who underwent a clinical evaluation at home2. Of the 4879 participants to whom the accelerometer was proposed in the Whitehall II Study, 388 did not consent and 210 had contraindications (allergies to plastic or metal, travelling abroad the following week). Of the remaining 4281 participants who wore the accelerometer, 4204 (98.2%) had valid accelerometer data (a readable data file). Among them, sleep diary data were missing for 80 participants and 29 additional participants did not meet criteria for accelerometer wear time (at least one night defined as noon-noon with >16 h of wear time). Of the remaining 4095 participants (a total of 27,966 nights) 342 did not have complete demographic data (age, BMI and sex). Therefore, the main assessment of discrepancies between the accelerometer and the sleep diary was undertaken in 3752 participants (76.9% of those invited) with a total of 25,645 nights11. The resulting participants (75.2% men) were on average 69.1 (standard deviation (SD) = 5.6) years old and had a mean body mass index (BMI) of 26.4 (SD = 4.2) kg/m2. Sleep clinic patients: these data come from 28 adult patients who were scheduled for a one-night polysomnography (PSG) assessment at the Freeman Hospital, Newcastle upon Tyne, UK, as part of their routine clinical assessment and were subsequently invited to participate in the study11. All 28 patients recruited for the polysomnography study (11 female) had complete accelerometer data for the left wrist and 27 had complete data for the right wrist and were aged between 21 and 72 years (mean ± sd: 45 ± 15 years). Diagnosed sleep disorders included: hypersomnia (N = 2), insomnia (N = 2), REM behaviour disorder (N = 3), sleep apnoea (N = 5), narcolepsy (N = 1), sleep apnoea (N = 4), parasomnia (N = 1), restless leg syndrome (N = 5), and sleep paralysis (N = 1), and nocturnia (N = 1). Three patients had more than one sleep disorder. Healthy good sleepers: these data come from 22 adults who underwent a one-night PSG assessment at the University of Pennsylvania Center for Sleep. Twenty-two participants recruited for the polysomnography study (68% female) had complete accelerometer data for the non-dominant wrist and were aged between 18 and 35 years (mean ± sd: 22.8 ± 4.5 years). Ethics Statement In all three studies participants were provided with instructions and an information sheet about the study and were given time to ask questions prior to providing written informed consent. The studies were approved by the University College London ethics committee (85/0938) and the NRES Committee North East Sunderland ethics committee (12/NE/0406), and University of Pennsylvania ethics committee (819591) respectively. All experiments were performed in accordance with relevant guidelines and regulations. Instrumentation Participants in the Whitehall II Study were asked to wear a tri-axial accelerometer (GENEActiv, Activinsights Ltd, Kimbolton, UK) on their non-dominant wrist for nine (24-h) consecutive days. They were asked to complete a simple sleep diary every morning which consisted of two questions: ‘what time did you first fall asleep last night?’ and ‘what time did you wake up today (eyes open, ready to get up)?’ The accelerometer was configured to collect data at 85.70 Hz with a ±8 g dynamic range. A more complete description of the accelerometer protocol can be found in our earlier publication2. In the second and third study, polysomnography (Embletta®, Denver) was performed using a standard procedure, including video recording, a sleep electroencephalogram (leads C4-A1 and C3-A2), bilateral eye movements, submental EMG, and bilateral anterior tibialis EMG to record leg movements

Read the complete text