Diagnostic Performance of In-Procedure Angiography-Derived Quantitative Flow Reserve Compared to Pressure-Derived Fractional Flow Reserve: The FAVOR II Europe-Japan Study.
Westra J, Andersen BK, Campo G, Matsuo H, Koltowski L, Eftekhari A, Liu T, Di Serafino L, Di Girolamo D, Escaned J, Nef H, Naber C, Barbierato M, Tu S, Neghabat O, Madsen M, Tebaldi M, Tanigaki T, Kochman J, Somi S, Esposito G, Mercone G, Mejia-Renteria H, Ronco F, Bøtker HE, Wijns W, Christiansen EH, Holm NR. · 2018
Read Diagnostic Performance of In-Procedure Angiography-Derived Quantitative Flow Reserve Compared to Pressure-Derived Fractional Flow Reserve: The FAVOR II Europe-Japan Study. by Westra J, Andersen BK, Campo G, Matsuo H, Koltowski L, Eftekhari A, Liu T, Di Serafino L, Di Girolamo D, Escaned J, Nef H, Naber C, Barbierato M, Tu S, Neghabat O, Madsen M, Tebaldi M, Tanigaki T, Kochman J, Somi S, Esposito G, Mercone G, Mejia-Renteria H, Ronco F, Bøtker HE, Wijns W, Christiansen EH, Holm NR. (2018) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc6064860.txt.
Introduction
Westra and co-authors test a wire-free way to judge coronary artery narrowing. Their FAVOR II Europe-Japan study appeared in the Journal of the American Heart Association. The standard test, fractional flow reserve, needs a pressure wire. The new method, quantitative flow ratio, computes flow from angiogram images alone.
Eleven centers enrolled 329 patients with stable angina. Paired readings covered 317 lesions. The computed method beat standard image reading on accuracy. Its sensitivity and specificity both reached about 87 percent. Results took a median of five minutes of procedure time. Readers get multicenter evidence for faster lesion checks in the cath lab.
Catalog record
| CREATOR | Westra J, Andersen BK, Campo G, Matsuo H, Koltowski L, Eftekhari A, Liu T, Di Serafino L, Di Girolamo D, Escaned J, Nef H, Naber C, Barbierato M, Tu S, Neghabat O, Madsen M, Tebaldi M, Tanigaki T, Kochman J, Somi S, Esposito G, Mercone G, Mejia-Renteria H, Ronco F, Bøtker HE, Wijns W, Christiansen EH, Holm NR. |
|---|---|
| YEAR | 2018 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 45 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Diagnostic Performance of In‐Procedure Angiography‐Derived Quantitative Flow Reserve Compared to Pressure‐Derived Fractional Flow Reserve: The FAVOR II Europe‐Japan Study By Jelmer Westra, Birgitte Krogsgaard Andersen, Gianluca Campo, Hitoshi Matsuo, Lukasz Koltowski, Ashkan Eftekhari, Tommy Liu, Luigi Di Serafino, Domenico Di Girolamo, Javier Escaned, Holger Nef, Christoph Naber Published in: Journal of the American Heart Association: Cardiovascular and Cerebrovascular Disease DOI: 10.1161/JAHA.118.009603 ABSTRACT Abstract Background Quantitative flow ratio (QFR) is a novel modality for physiological lesion assessment based on 3‐dimensional vessel reconstructions and contrast flow velocity estimates. We evaluated the value of online QFR during routine invasive coronary angiography for procedural feasibility, diagnostic performance, and agreement with pressure‐wire–derived fractional flow reserve (FFR) as a gold standard in an international multicenter study. Methods and Results FAVOR II E‐J (Functional Assessment by Various Flow Reconstructions II Europe‐Japan) was a prospective, observational, investigator‐initiated study. Patients with stable angina pectoris were enrolled in 11 international centers. FFR and online QFR computation were performed in all eligible lesions. An independent core lab performed 2‐dimensional quantitative coronary angiography (2D‐QCA) analysis of all lesions assessed with QFR and FFR. The primary comparison was sensitivity and specificity of QFR compared with 2D‐QCA using FFR as a reference standard. A total of 329 patients were enrolled. Paired assessment of FFR, QFR, and 2D‐QCA was available for 317 lesions. Mean FFR, QFR, and percent diameter stenosis were 0.83±0.09, 0.82±10, and 45±10%, respectively. FFR was ≤0.80 in 104 (33%) lesions. Sensitivity and specificity by QFR was significantly higher than by 2D‐QCA (sensitivity, 86.5% (78.4–92.4) versus 44.2% (34.5–54.3); P<0.001; specificity, 86.9% (81.6–91.1) versus 76.5% (70.3–82.0); P=0.002). Area under the receiver curve was significantly higher for QFR compared with 2D‐QCA (area under the receiver curve, 0.92 [0.89–0.96] versus 0.64 [0.57–0.70]; P<0.001). Median time to QFR was significantly lower than median time to FFR (time to QFR, 5.0 minutes [interquartile range, –6.1] versus time to FFR, 7.0 minutes [interquartile range, 5.0–10.0]; P<0.001). Conclusions Online computation of QFR in the catheterization laboratory is clinically feasible and is superior to angiographic assessment for evaluation of intermediary coronary artery stenosis using FFR as a reference standard. Clinical Trial Registration URL: https://www.clinicaltrials.gov. Unique identifier: NCT02959814. Keywords: fractional flow reserve, quantitative coronary angiography Subject Categories: Angiography, Diagnostic Testing, Imaging Clinical PerspectiveWhat Is New? Quantitative flow ratio (QFR) estimates fractional flow reserve based on computation of 2 standard angiographic projections.Online QFR performed during invasive angiography is feasible and can be computed within the time of conventional fractional flow reserve measurement.QFR has superior sensitivity and specificity for detection of functional significant lesions in comparison with 2‐dimensional quantitative coronary angiography using fractional flow reserve as reference. What Are the Clinical Implications? QFR may broaden the access to physiological lesion assessment in diagnostic catheterization laboratories and centers with low adoption of pressure‐wire–based diagnostic strategies.Randomized trials are required to confirm that QFR provides noninferior clinical outcome compared to assessment of intermediate coronary stenosis by pressure wire. INTRODUCTION Physiological assessment is the clinical standard to guide percutaneous coronary interventions of intermediate coronary stenosis. Following the FAME (Fractional Flow Reserve Versus Angiography for Multivessel Evaluation [fractional flow reserve versus angiography for guiding percutaneous coronary intervention]) trials, the adoption of fractional flow reserve (FFR) has improved with a 16‐fold increase in FFR‐guided percutaneous coronary intervention in the United States from 2008 to 2012.1 Globally, the use of physiological lesion assessment remains low, with large areas performing less than 15% of eligible procedures with physiology guidance.2, 3 To further expand the use of physiological‐guided percutaneous coronary intervention, coronary computed tomography angiography– and invasive coronary angiography–based computation methods were developed for less‐invasive FFR approximation.4, 5, 6, 7, 8, 9, 10 Quantitative flow ratio (QFR) is a method for fast computation of FFR based on 3‐dimensional quantitative coronary angiography (3D‐QCA) and estimation of contrast flow velocity during invasive coronary angiography. The optimal approach was validated in the FAVOR (Functional Assessment by Various Flow Reconstructions) multicenter study, proving that QFR can be computed without pharmacology‐induced hyperemia.11 In FAVOR, QFR was computed post hoc in a core‐lab setting. The FAVOR II China study, conducted in parallel to FAVOR II Europe‐Japan (E‐J), showed a high diagnostic accuracy of in‐procedure QFR.12 In FAVOR II E‐J, we aimed to validate the in‐procedure feasibility and compare the diagnostic performance of QFR computation with 2‐dimensional quantitative coronary angiography (2D‐QCA) in a multicenter setting, using FFR as a reference standard. METHODS Study Design FAVOR II E‐J was a prospective, blinded, observational study with paired assessment of QFR, 2D‐QCA, and FFR performed at 11 international sites: Italy (4), The Netherlands (1), Germany (2), Poland (1), Spain (1), Japan (1), and Denmark (1). Clinicaltrials.gov identifier: NCT02959814. Primary Comparison The primary comparison was sensitivity and specificity of QFR compared with 2D‐QCA to detect hemodynamically significant coronary lesions with FFR as a gold standard. For FFR and QFR, significant obstructions were defined as FFR and QFR ≤0.80 whereas >50% diameter stenosis (% DS) was used for 2D‐QCA. Sample‐size calculation and a full list of secondary comparisons are provided in Data S1 and Table S1. Patient Population Patients with stable angina pectoris or patients scheduled for secondary evaluation of stenosis after acute myocardial infarction were eligible for enrollment when the angiographic inclusion criteria were met; indication for FFR measurement (at least 1 lesion with % DS 30–90 in a vessel with reference size >2.0 mm). Exclusion criteria were: acute myocardial infarction within 72 hours; severe asthma or severe chronic obstructive pulmonary disease; allergy to contrast media or adenosine; or atrial fibrillation. All inclusion and exclusion criteria are listed in Table S2. Ethics The study was approved by the Central Denmark Region Committees on Biomedical Research Ethics. Approval by local or national medical ethics committees was obtained by the local or national coordinating investigators as required for the individual sites. The Danish Data Protection Agency approved the study. All enrolled patients provided written informed consent. J.W. and N.R.H. had full access to all data in the study. All authors are responsible for integrity of the analysis. The data will not be made available to other researchers for purposes of reproducing the results or replication the procedure because of competitive reasons. Study Procedure Invasive coronary angiography Nitroglycerine (100–200 μg IC) was administrated after acquiring the first angiographic projection. If FFR was indicated in 1 or more vessels, 2 study projections were obtained for each lesion of interest at a minimum of 12.5 frames per second. Selection of projections aimed for minimal vessel foreshortening and minimal vessel overlap by: (1) brisk, continuous and fast contrast injections and (2) no zooming and movement of the table and visualization of the entire vessel to the intended location of the pressure transducer. A table of recommended projection angles was provided for all study sites (Table S3). Images were transferred to a workstation for computation of QFR following site‐specific blinding protocols (Data S1). The remaining diagnostic invasive coronary angiography and further interventions were performed per normal clinical practice. QFR computation QFR was computed with the CE‐marked software; QAngio XA‐3D/QFR solution (Medis medical imaging system bv., Leiden, The Netherlands). An end‐diastolic frame was selected for each study projection and was used for the 3‐dimensional reconstruction of the segmented vessel. The reference vessel was constructed by fitting to healthy segments preferably proximal and