Read Single-breath-hold photoacoustic computed tomography of the breast. by Lin L, Hu P, Shi J, Appleton CM, Maslov K, Li L, Zhang R, Wang LV. (2018) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc6003984.txt.

Introduction

Lin and co-authors develop single-breath-hold photoacoustic computed tomography of the breast. Their study appeared in Nature Communications. The system images blood vessels deep in breast tissue. It reaches 4 centimetres deep in living patients. In-plane detail is 255 micrometres, at ten frames per second. A full volume scan takes about 15 seconds. One held breath thus avoids motion blur in the images.

Tumours stand out through their denser vessel networks, they report. The method needs no ionising radiation or injected contrast. Patients ranged from B to DD cup sizes. All tumours were found in the test group. Dynamic imaging can also probe tissue stiffness.

Catalog record

CREATORLin L, Hu P, Shi J, Appleton CM, Maslov K, Li L, Zhang R, Wang LV.
YEAR2018
COLLECTIONPAPERS
FORMATTXT
FILE SIZE55 KB
LICENSECC BY 4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/articles/PMC6003984

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Single-breath-hold photoacoustic computed tomography of the breast By Li Lin, Peng Hu, Junhui Shi, Catherine M. Appleton, Konstantin Maslov, Lei Li, Ruiying Zhang, Lihong V. Wang Published in: Nature Communications DOI: 10.1038/s41467-018-04576-z ABSTRACT We have developed a single-breath-hold photoacoustic computed tomography (SBH-PACT) system to reveal detailed angiographic structures in human breasts. SBH-PACT features a deep penetration depth (4 cm in vivo) with high spatial and temporal resolutions (255 µm in-plane resolution and a 10 Hz 2D frame rate). By scanning the entire breast within a single breath hold (~15 s), a volumetric image can be acquired and subsequently reconstructed utilizing 3D back-projection with negligible breathing-induced motion artifacts. SBH-PACT clearly reveals tumors by observing higher blood vessel densities associated with tumors at high spatial resolution, showing early promise for high sensitivity in radiographically dense breasts. In addition to blood vessel imaging, the high imaging speed enables dynamic studies, such as photoacoustic elastography, which identifies tumors by showing less compliance. We imaged breast cancer patients with breast sizes ranging from B cup to DD cup, and skin pigmentations ranging from light to dark. SBH-PACT identified all the tumors without resorting to ionizing radiation or exogenous contrast, posing no health risks. INTRODUCTION Breast cancer is the second most common cancer to affect women in the U.S. and is the second ranked cause of cancer-related deaths. About 1 in 8 (12%) women in the U.S. will develop invasive breast cancer during their lifetime1. Multiple large prospective clinical trials have demonstrated the importance of early detection in improving breast cancer survival2–4. While mammography is currently the gold standard used for breast cancer screening, it utilizes ionizing radiation and has lower sensitivity in women with dense breasts5, 6. Ultrasonography has been used as an adjunct to mammography, but suffers from speckle artifacts and low specificity7, 8. Magnetic resonance imaging (MRI) poses a large financial burden and requires the use of intravenous contrast agents that can cause allergy9, kidney damage10, and permanent deposition in the central nervous system11. Diffuse optical tomography has been investigated to provide functional optical contrast. However, the spatial resolution of the current prototypes limits their clinical use12, 13. Overall, each modality has notable advantages and limitations. Photoacoustic computed tomography (PACT) is a promising complementary modality that overcomes many of these limitations. PACT—ultrasonically imaging optical contrast via the photoacoustic effect—breaks through the ~1 mm optical diffusion limit on penetration for high-resolution optical imaging in deep tissues14, 15. It combines the functional optical contrast of diffuse optical tomography and the high spatial resolution of ultrasonography. The rich contrast bestowed by optical absorption, which is related to various intrinsic and extrinsic contrast origins, enables PACT to perform structural, functional, and molecular imaging16. When a short-pulsed laser irradiates biological tissues, wideband ultrasonic waves (referred to as photoacoustic waves) are induced by transient thermoelastic expansion. The photoacoustic (PA) waves are then simultaneously measured by ultrasonic transducers around the tissue and are used to reconstruct the optical absorption distribution in the tissue17. In the near-infrared (NIR) region, the 1/e attenuation coefficient (1.0–1.3 cm−1)18 for light in an average breast is less than twice that for mammographic X-rays (0.5–0.8 cm−1)19. However, the optical absorption contrast of soft tissue is much higher than X-ray contrast20. For breast imaging, PACT can exploit these advantages to the fullest, offering high spatial and temporal resolutions with sufficiently deep nonionizing optical penetration21, 22. As the principal optical absorber in the NIR region, hemoglobin provides an endogenous contrast for imaging of blood vessels. A high density of blood vessels should correlate with angiogenesis23–25, which plays an important role in tumor growth and metastasis26. Several breast PACT systems have been developed, employing different light illumination and detection schemes27–36. These systems have advanced PACT toward clinical application, but ongoing limitations remain to be addressed. Here, we consider five main factors: (1) sufficient penetration depth to accommodate most breast sizes and skin colors, (2) high spatial resolution to reveal detailed angiographic structures, (3) high temporal resolution to minimize motion artifacts and enable dynamic or functional studies, (4) minimal limited-view artifacts, and (5) sufficient noise-equivalent sensitivity and contrast-to-noise ratio to detect breast masses. Specifically, the current systems’ limitations mainly arise from their long scanning times27–29 and/or limited-view apertures (i.e., missing data or a <2π steradian solid angle)29–35. Toi et al. recently reported a photoacoustic imaging system with a hemispherical detector array27, which was modified from a previous design28. Although the design for acoustic detection is slightly different, both used a sparse hemispherical detector array and scanned in a spiral pattern on a plane. The dense sampling, and the nearly isotropic 3D spatial resolutions produced elegant vascular images, but tumor detection was limited by respiratory motion artifacts resulting from the long scanning time (~4 min). Although co-registration partially mitigated the breathing motion distortion, the non-rigidity of the breast compromised the effectiveness. While larger vessels were coregistered, small tumor vessels, which often occur in small clusters, could be challenging to be imaged with partial data and even more difficult to be coregistered. Other groups have used planar transducer arrays30–33 and arc-shaped arrays34 for breast imaging. However, the limited views of these systems decreased their overall performances37, 38. Consequently, most blood vessels were not well visualized in their images. The same problem occurred with linear transducer arrays, either fixed in position35 or scanned29. A ring-shaped array of 32 elements was developed at presumably relatively low system cost36. However, the low number of elements severely limited the field of view due to the spatial Nyquist sampling criterion, resulting in degradation of image quality39. Here, we report a significant advancement in breast PACT technology that overcomes all of the aforementioned limitations. Our breast imaging modality—single-breath-hold PACT (SBH-PACT)—is the first PACT system that meets the aforementioned five conditions: (1, 2) Combining 1064-nm light illumination and a 2.25-MHz unfocused ultrasonic transducer array, SBH-PACT achieved up to 4 cm in vivo imaging depth and a 255 µm in-plane resolution (approximately four times finer than that of contrast-enhanced MRI40). (3) Equipped with one-to-one mapped signal amplification and data acquisition (DAQ) circuits, SBH-PACT can obtain an entire 2D cross-sectional breast image with a single laser pulse, or obtain a volumetric 3D image of the entire breast by fast elevational scanning within a single breath-hold (~15 s). The 10 Hz 2D frame rate, currently limited by the laser repetition rate, enables SBH-PACT to observe biological dynamics in a cross-section associated with respiration and heartbeats without motion artifacts. (4) A full-ring 512-element ultrasonic transducer array enables SBH-PACT for full-view fidelity in 2D imaging planes and delivers high image quality. (5) Capitalizing on the optimized illumination method and signal amplification, SBH-PACT achieves sufficient noise-equivalent sensitivity to clearly reveal detailed angiographic structures both inside and outside breast tumors without the use of exogenous contrast agents. In this pilot study, SBH-PACT was used to image one healthy volunteer and seven breast cancer patients. SBH-PACT clearly identified eight of the nine breast tumors by delineation of angiographic anatomy. These tumors were subsequently verified by ultrasound-guided biopsy. In addition, to improve on the interpretation of images, we developed an algorithm to highlight tumors automatically. Tumors were clearly revealed by SBH-PACT in all breasts even in radiographically dense breasts, which could not be readily imaged by mammography. Taking

Read the complete text