Read A Review of the Evolution of Vision-Based Motion Analysis and the Integration of Advanced Computer Vision Methods Towards Developing a Markerless System. by Colyer SL, Evans M, Cosker DP, Salo AIT. (2018) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc5986692.txt.
Introduction
Colyer and co-authors review the evolution of vision-based motion analysis toward a markerless system. Their narrative review appeared in Sports Medicine - Open. Motion study in sport and rehabilitation has advanced for decades. A system that is accurate, quick, and unobtrusive is still missing. Marker-based optical systems dominate current practice. They need markers stuck on the body and controlled settings. Long processing times also limit routine use.
Markerless methods are emerging from entertainment technology, the authors note. Computer vision and machine learning drive the new tools. Some already measure walking angles within two or three degrees. Accuracy across movements and settings is not yet proven. Joint work between fields is needed.
Catalog record
| CREATOR | Colyer SL, Evans M, Cosker DP, Salo AIT. |
|---|---|
| YEAR | 2018 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 71 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
A Review of the Evolution of Vision-Based Motion Analysis and the Integration of Advanced Computer Vision Methods Towards Developing a Markerless System By Steffi L. Colyer, Murray Evans, Darren P. Cosker, Aki I. T. Salo Published in: Sports Medicine - Open DOI: 10.1186/s40798-018-0139-y ABSTRACT Background The study of human movement within sports biomechanics and rehabilitation settings has made considerable progress over recent decades. However, developing a motion analysis system that collects accurate kinematic data in a timely, unobtrusive and externally valid manner remains an open challenge. Main body This narrative review considers the evolution of methods for extracting kinematic information from images, observing how technology has progressed from laborious manual approaches to optoelectronic marker-based systems. The motion analysis systems which are currently most widely used in sports biomechanics and rehabilitation do not allow kinematic data to be collected automatically without the attachment of markers, controlled conditions and/or extensive processing times. These limitations can obstruct the routine use of motion capture in normal training or rehabilitation environments, and there is a clear desire for the development of automatic markerless systems. Such technology is emerging, often driven by the needs of the entertainment industry, and utilising many of the latest trends in computer vision and machine learning. However, the accuracy and practicality of these systems has yet to be fully scrutinised, meaning such markerless systems are not currently in widespread use within biomechanics. Conclusions This review aims to introduce the key state-of-the-art in markerless motion capture research from computer vision that is likely to have a future impact in biomechanics, while considering the challenges with accuracy and robustness that are yet to be addressed. KEY POINTS Biomechanists aspire to have motion analysis tools that allow movement to be accurately measured automatically and unobtrusively in applied (e.g. everyday training) situationsInnovative markerless techniques developed primarily for entertainment purposes provide a potentially promising solution, with some systems capable of measuring sagittal plane angles to within 2°–3° during walking gait. However, accuracy requirements vary across different scenarios and the validity of markerless systems has yet to be fully established across different movements in varying environmentsFurther collaborative work between computer vision experts and biomechanists is required to develop such techniques further to meet the unique practical and accuracy requirements of motion analysis for sports and rehabilitation applications. REVIEW Background Vision-based motion analysis involves extracting information from sequential images in order to describe movement. It can be traced back to the late nineteenth century and the pioneering work of Eadweard Muybridge who first developed techniques to capture image sequences of equine gait [1]. Motion analysis has since evolved substantially in parallel with major technological advancements and the increasing demand for faster, more sophisticated techniques to capture movement in a wide range of settings ranging from clinical gait assessment [2] to video game animation [3]. Within sports biomechanics and rehabilitation applications, quantitative analysis of human body kinematics is a powerful tool that has been used to understand the performance determining aspects of technique [4], identify injury risk factors [5], and facilitate recovery from injury [6] or trauma [7]. Biomechanical tools have developed considerably from manual annotation of images to marker-based optical trackers, inertial sensor-based systems and markerless systems using sophisticated human body models, computer vision and machine learning algorithms. The aim of this review is to cover some of the history of the development and use of motion analysis methods within sports and biomechanics, highlighting the limitations of existing systems. The state-of-the-art technologies from computer vision and machine learning, which have started to emerge within the biomechanics community, are introduced. This review considers how these new technologies could revolutionise the fields of sports biomechanics and rehabilitation by broadening the applications of motion analysis to include everyday training or competition environments. General Principles and Requirements of Vision-Based Motion Analysis in Sports Biomechanics and Rehabilitation Optical motion analysis requires the estimation of the position and orientation (pose) of an object across image sequences. Through the identification of common object features in successive images, displacement data can be “tracked” over time. However, accurate quantification of whole-body pose can be a difficult problem to solve since the human body is an extremely complex, highly articulated, self-occluding and only partially rigid entity [8–10]. To make this process more tractable, the structure of the human body is usually simplified as a series of rigid bodies connected by frictionless rotational joints. Three-dimensional (3D) pose of rigid segments can be fully specified by six degrees of freedom (DOF): three relating to translation and three defining orientation. As such, even for a relatively simple 14-segment human body model, a large number of DOF (potentially as many as 84 depending on the anatomical constraints employed) need to be recovered to completely characterise 3D body configuration. From such a model, it is possible to compute joint angles, and with the incorporation of body segment inertia parameters, the whole body centre of mass location can be deduced, as in previous research in sprinting [11, 12], gymnastics [13] and rugby place-kicking [14]. Moreover, kinematic and kinetic data can be combined to allow the calculation of joint moments and powers through inverse dynamics analysis [15]. Such analyses have value across diverse areas from, for example, understanding lower-limb joint power production across fatiguing cycling efforts [16] to characterising joint torque profiles following anterior cruciate ligament reconstruction surgery [17]. However, obtaining accurate body pose is an essential step before reliable joint moments (and powers) can be robustly acquired, as inaccuracies in kinematic data will propagate to larger errors in joint kinetic parameters [18]. In certain cases within biomechanics, two-dimensional (2D) analyses using relatively simple body models suffice. Examples include when assessing movements which are considered to occur primarily in the sagittal plane such as walking [19] and sprinting [4], or when experimental control is limited, such as when ski jumpers’ body positions were analysed during Olympic competition [20]. Conversely, when the movement under analysis occurs in multiple planes, a multi-camera system and a more complex 3D model are required; for instance, when investigating shoulder injury risks associated with different volleyball spiking techniques [21]. The more extensive experimental set-ups for whole-body 3D analysis typically necessitate controlled laboratory environments and a challenge is to then ensure ecological validity (that movements accurately represent reality). The main differences between 2D and 3D analysis relate to the complexity of the calibration and coordinate reconstruction processes, and joint angle definitions. Planar (2D) analysis can be conducted with only one camera, whereas at least two different perspectives are required to triangulate 2D information into 3D real-space coordinates [22, 23]. The number of DOF that need to be recovered (and consequently the number of markers required) in order to define segment (or any rigid body) pose differs between 2D and 3D methods. In 2D analysis, it is only possible to recover three DOF and this requires a minimum of two known points on the segment. Conversely, for 3D reconstruction of a rigid body, six DOF can be specified by identifying at least three non-collinear points. A wide range of motion analysis systems allow movement to be captured in a variety of settings, which can broadly be categorised into direct (devices affixed to the body, e.g. accelerometry) and indirect (vision-based, e.g. video or optoelectronic)