Using Fitness Trackers and Smartwatches to Measure Physical Activity in Research: Analysis of Consumer Wrist-Worn Wearables.
Henriksen A, Haugen Mikalsen M, Woldaregay AZ, Muzny M, Hartvigsen G, Hopstock LA, Grimsgaard S. · 2018
Read Using Fitness Trackers and Smartwatches to Measure Physical Activity in Research: Analysis of Consumer Wrist-Worn Wearables. by Henriksen A, Haugen Mikalsen M, Woldaregay AZ, Muzny M, Hartvigsen G, Hopstock LA, Grimsgaard S. (2018) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc5887043.txt.
Introduction
Henriksen and co-authors survey fitness trackers and smartwatches for research use. Their article appeared in the Journal of Medical Internet Research. New wrist devices reach the market every year. They differ in sensors, algorithms, and apps. The team searched six device databases for wrist wearables. They mapped 423 devices from 132 brands, from 2011 to 2017. Only devices with accelerometers were counted in the survey.
Nearly half of brands released a single device. Sensor support grew each year of the window. Heart rate sensors were the commonest extra feature. Fitbit, Garmin, Misfit, Apple, and Polar led research use. The team also checked developer access to health data. Fitbit appeared in twice as many validation studies as rivals.
Catalog record
| CREATOR | Henriksen A, Haugen Mikalsen M, Woldaregay AZ, Muzny M, Hartvigsen G, Hopstock LA, Grimsgaard S. |
|---|---|
| YEAR | 2018 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 66 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Using Fitness Trackers and Smartwatches to Measure Physical Activity in Research: Analysis of Consumer Wrist-Worn Wearables By Gunther Eysenbach, James Sanders, Petra Wark, Kyle Winfree, Ramin Fallahzadeh, César Fernández, André Henriksen, Martin Haugen Mikalsen, Ashenafi Zebene Woldaregay, Miroslav Muzny, Gunnar Hartvigsen, Laila Arnesdatter Hopstock Published in: Journal of Medical Internet Research DOI: 10.2196/jmir.9157 ABSTRACT Background New fitness trackers and smartwatches are released to the consumer market every year. These devices are equipped with different sensors, algorithms, and accompanying mobile apps. With recent advances in mobile sensor technology, privately collected physical activity data can be used as an addition to existing methods for health data collection in research. Furthermore, data collected from these devices have possible applications in patient diagnostics and treatment. With an increasing number of diverse brands, there is a need for an overview of device sensor support, as well as device applicability in research projects. Objective The objective of this study was to examine the availability of wrist-worn fitness wearables and analyze availability of relevant fitness sensors from 2011 to 2017. Furthermore, the study was designed to assess brand usage in research projects, compare common brands in terms of developer access to collected health data, and features to consider when deciding which brand to use in future research. Methods We searched for devices and brand names in six wearable device databases. For each brand, we identified additional devices on official brand websites. The search was limited to wrist-worn fitness wearables with accelerometers, for which we mapped brand, release year, and supported sensors relevant for fitness tracking. In addition, we conducted a Medical Literature Analysis and Retrieval System Online (MEDLINE) and ClinicalTrials search to determine brand usage in research projects. Finally, we investigated developer accessibility to the health data collected by identified brands. Results We identified 423 unique devices from 132 different brands. Forty-seven percent of brands released only one device. Introduction of new brands peaked in 2014, and the highest number of new devices was introduced in 2015. Sensor support increased every year, and in addition to the accelerometer, a photoplethysmograph, for estimating heart rate, was the most common sensor. Out of the brands currently available, the five most often used in research projects are Fitbit, Garmin, Misfit, Apple, and Polar. Fitbit is used in twice as many validation studies as any other brands and is registered in ClinicalTrials studies 10 times as often as other brands. Conclusions The wearable landscape is in constant change. New devices and brands are released every year, promising improved measurements and user experience. At the same time, other brands disappear from the consumer market for various reasons. Advances in device quality offer new opportunities for research. However, only a few well-established brands are frequently used in research projects, and even less are thoroughly validated. INTRODUCTION Background The World Health Organization recommends 150 min of moderate intensity physical activity (PA) each week for adults and 60 min for children and adolescents [1]. However, 25% of adults and more than 80% of adolescents do not achieve the recommended PA targets [1]. Results from the Tromsø Study, the longest running population study in Norway, shows that only 30.4% of women and 22.0% of men reach the recommended target [2]. Low PA is currently the fourth leading risk factor for mortality worldwide [3]. Even though there is limited evidence that using wearable fitness trackers will improve health [4,5], these devices are still popular, and new fitness devices appear on the consumer market regularly. In 2016, vendors shipped 102 million devices worldwide, compared with 82 million in 2015 [6]. Fifty-seven percent of these devices were sold by the top five brands: Fitbit, Xiaomi, Apple, Garmin, and Samsung. The first quarter of 2017 shows an increase of 18% in devices sold, compared with the same period in 2016 [7]. With a large number of available devices and brands, it is difficult to navigate through an ever-growing list of brands and devices with different capabilities, price, and quality. Available sensors and internal interpreting algorithms determine device output. Sensor data are, in most devices, reduced to a limited set of metrics before being transferred to the user’s mobile phone. In addition, limited space affects how long the device can collect data before such a transfer is needed. Data are stored locally, and in many cases, uploaded to brand specific or open cloud–based health repositories. Accessing these data by third-party apps and comparing them is not always possible. These interoperability challenges were recently identified in a study by Arriba-Pérez et al [8]. They suggested ways to handle these issues, but they did not make any brand or device recommendations. Several studies have compared activity-tracking wearables. As an example, Kaewkannate and Kim [9] did a comparison of four popular fitness trackers in 2016. They compared devices objectively and subjectively. Data were thoroughly collected, but because of the rapid release of new devices, these four devices will be among the most popular only for a relatively short time. A comparison of brands is also of interest because brands from larger companies are, compared with small start-ups and crowd funded brands, likely to survive longer. In addition, it is of interest to know which brands support the various available programming options. Sanders et al [10] did a literature review on articles using wearables for health self-monitoring and sedentary behavior and PA detection. They reviewed various aspects of these devices, but they gave no details about device sensor support and suitability in research. The objective of this study was to examine how the consumer market for wearables has evolved, and analyze and summarize available devices that can measure PA and heart rate (HR). Moreover, we aim to identify brands that are used extensively in research projects, and compare and consider their relevance for future studies. Sensors A plethora of devices promises to measure PA in new and improved ways. These devices use different sensors and algorithms to calculate human readable metrics based on sensor output. Traditional step counters use pedometers to detect daily step counts. Although cheap and energy efficient, pedometers are not as accurate as accelerometers, which is the current standard for collecting PA data [11]. All modern fitness trackers and smartwatches have an accelerometer. Compared with research tools (eg, ActiGraph [12]), these devices are considered less accurate for some measurements [13,14]. However, they are generally less invasive, cheaper, have more functionality, are more user-friendly, and are increasingly being used in research. Most accelerometer-based fitness wearables measure acceleration in three directions [15] and can be used to estimate type of movement, count steps, calculate energy expenditure (EE) and energy intensity, as well as estimate sleep patterns and more. The validity and reliability of these metrics varies. Evenson et al [14] did a review in 2015 and found high validity for steps but low validity for EE and sleep. Furthermore, they found reliability for steps, distance, EE, and sleep to be high for some devices. In addition, some wearables have gyroscopes, magnetometers, barometers, and altimeters. A gyroscope can potentially increase device accuracy by measuring gravitational acceleration, that is, orientation and angular velocity, and better estimate which activity type a person is performing [16]. A magnetometer is a digital compass [15] and can improve motion tracking