Enzyme-linked immunosorbent assay for the quantitative/qualitative analysis of plant secondary metabolites.
Sakamoto S, Putalun W, Vimolmangkang S, Phoolcharoen W, Shoyama Y, Tanaka H, Morimoto S. · 2018
Read Enzyme-linked immunosorbent assay for the quantitative/qualitative analysis of plant secondary metabolites. by Sakamoto S, Putalun W, Vimolmangkang S, Phoolcharoen W, Shoyama Y, Tanaka H, Morimoto S. (2018) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc5775980.txt.
Introduction
Sakamoto and co-authors review ELISA tests for plant secondary metabolites. These compounds help plants defend themselves and include many drug and health product ingredients. ELISA uses antibody binding to measure a target with high specificity. The method grew from older radioisotope assays, swapped for safer enzyme labels.
The review explains how the assays are built and read. It covers antibodies and probes, helped by recombinant DNA methods. Worked uses show the tests in quality control of plant products. The authors also note where the tests serve diagnosis and drug monitoring more broadly.
Catalog record
| CREATOR | Sakamoto S, Putalun W, Vimolmangkang S, Phoolcharoen W, Shoyama Y, Tanaka H, Morimoto S. |
|---|---|
| YEAR | 2018 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 43 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Enzyme-linked immunosorbent assay for the quantitative/qualitative analysis of plant secondary metabolites By Seiichi Sakamoto, Waraporn Putalun, Sornkanok Vimolmangkang, Waranyoo Phoolcharoen, Yukihiro Shoyama, Hiroyuki Tanaka, Satoshi Morimoto Published in: Journal of Natural Medicines DOI: 10.1007/s11418-017-1144-z ABSTRACT Abstract Immunoassays are antibody-based analytical methods for quantitative/qualitative analysis. Since the principle of immunoassays is based on specific antigen–antibody reaction, the assays have been utilized worldwide for diagnosis, pharmacokinetic studies by drug monitoring, and the quality control of commercially available products. Berson and Yalow were the first to develop an immunoassay, known as radioimmunoassay (RIA), for detecting endogenous plasma insulin [1], a development for which Yalow was awarded the Nobel Prize in Physiology or Medicine in 1977. Even today, after half a century, immunoassays are widely utilized with some modifications from the originally proposed system, e.g., radioisotopes have been replaced with enzymes because of safety concerns regarding the use of radioactivity, which is referred to as enzyme immunoassay/enzyme-linked immunosorbent assay (ELISA). In addition, progress has been made in ELISA with the recent advances in recombinant DNA technology, leading to increase in the range of antibodies, probes, and even systems. This review article describes ELISA and its applications for the detection of plant secondary metabolites. Keywords: Antibodies, Enzyme-linked immunosorbent assay (ELISA), Hapten, Plant secondary metabolites INTRODUCTION Since the development of radioimmunoassay (RIA) in 1960, there has been a rapid increase in immunoassay techniques using radioactive labels [1]. However, radioactive labels have been gradually replaced with enzyme labels because of safety concerns associated with radioactivity since the study by Avrameas in 1969, who coupled antigens or antibodies and enzymes using glutaraldehyde [2]. Currently, ELISA has a higher number of immunoassays compared to RIA. Plant secondary metabolites are plant-produced organic compounds that play an important role in the defense of plants against herbivores, pests, and pathogens, as well as in their adaptation to the environment, although they are not directly involved in the growth and development of organisms [3, 4]. Because of their diverse functions, there has been a dramatic increase in their demand in pharmaceuticals, cosmetics, and pesticides, as well as in food additives [5]. Quality control of these commercial products containing secondary metabolites is crucial as the quality directly affects their potential activity. In addition, Cragg and Newman recently reported that 34% of the currently used drugs originate from natural products [6]. Meanwhile, simple, selective, and sensitive analytical techniques are also required in pharmacodynamic studies for monitoring effective concentration, side effects, and metabolism, leading to a better quality of life for patients. Thus far, various analytical methods have been developed for such purposes, mainly based on high-performance liquid chromatography (HPLC). However, ELISA exhibits several advantages over such techniques because of its simplicity, selectivity, and sensitivity. The basic facts about ELISA and its practical use for measuring plant secondary metabolites are described in this review. GENERAL PRINCIPLE OF ELISA ELISA is based on the concept of antigen–antibody reactions, representing the chemical interaction between antibodies produced by the B cells of leukocytes and antigens. This specific immune response plays an important role in protecting the body from invaders such as pathogens and toxins. Hence, by exploiting this reaction, ELISA permits the highly sensitive and selective quantitative/qualitative analysis of antigens, including proteins, peptides, nucleic acids, hormones, herbicides, and plant secondary metabolites. To detect these molecules, an antigen or antibody is labeled using enzymes, the so-called enzyme immunoassay, in which alkaline phosphatase (ALP) [7], horseradish peroxidase (HRP) [8], and β-galactosidase [9–11] are commonly used. The antigen in the fluid phase is immobilized on a solid phase, such as a microtiter plate constituting rigid polystyrene, polyvinyl chloride, and polypropylene. Subsequently, the antigen is allowed to react with a specific antibody, which is detected by an enzyme-labeled secondary antibody. The development of color using a chromogenic substrate corresponds to the presence of the antigen. For instance, ALP hydrolyzes p-nitrophenyl phosphate to produce p-nitrophenol, which can be detected at 405 nm (yellow color), and HRP catalyzes the conversion of chromogenic substrates, e.g., 2,2′-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) diammonium salt, 3,3′,5,5′-tetramethylbenzidine, and o-phenylenediamine into colored products. By using chemiluminescent substrates such as chloro-5-substituted adamantyl-1,2-dioxetane phosphate and luminol for ALP and HRP, respectively, and fluorogenic substrates such as 4-methylumbelliferyl galactoside and nitrophenyl galactoside for β-galactosidase, even more sensitive detection can be achieved. These enzyme–substrate reactions are typically completed within 30–60 min, and the reaction stops with the addition of an appropriate solution, e.g., sodium hydroxide, hydrochloric acid, sulfuric acid, sodium carbonate, and sodium azide, for individual reactions [12, 13]. Finally, colored or fluorescent products are detected using a microtiter plate reader. ADVANTAGES AND DISADVANTAGES OF ELISA Advantages and disadvantages of ELISA are summarized in Table 1. ELISA exhibits the following advantages: (i) Simple procedure. (ii) High specificity and sensitivity, because of an antigen–antibody reaction. (iii) High efficiency, as simultaneous analyses can be performed without complicated sample pre-treatment. (iv) Generally safe and eco-friendly, because radioactive substances and large amounts of organic solvents are not required. (v) Cost-effective assay, as low-cost reagents are used. However, ELISA exhibits the following disadvantages: (i) Labor-intensive and expensive to prepare antibody because it is a sophisticated technique, and expensive culture cell media are required to obtain a specific antibody. (ii) High possibility of false positive or negative results because of insufficient blocking of the surface of microtiter plate immobilized with antigen. (iii) Antibody instability because an antibody is a protein that requires refrigerated transport and storage. [Table: Advantages and disadvantages of ELISA] TYPES OF ELISA Direct ELISA In 1971, Engvall and Perlmann [14] and Van Weemen and Schuurs [15] were the first to develop direct ELISA (Fig. 1), which was the base style for other types of ELISA. Primarily, an antigen or an antibody is immobilized on the surface of microtiter plate. After the surface is blocked with other proteins (e.g., albumin, gelatin, casein, and skimmed-milk [13]) to avoid the non-specific adsorption of other proteins, the corresponding enzyme-labeled antibody or antigen is allowed to react with the immobilized targets, followed by color development with appropriate substrates. With an increasing amount of targets, the signal increases. Direct ELISA is suitable for the qualitative analysis of macromolecules. [Figure: Direct ELISA to detect antigen (a) and antibody (b). (i) Attach antigen/antibody to solid phase. (ii) Incubate with enzyme-labeled antibody/antigen. (iii) Wash unbound enzyme-labeled antibody/antigen out. (iv) Develop color with substrate] Competitive ELISA In 1973, Belanger developed competitive ELISA (Fig. 2) to detect rat α-fetoprotein, which involved the development of indirect ELISA and sandwich ELISA [16]. The key event of competitive ELISA is the competitive reaction between targets (antigen or antibody) in the sample and enzyme-labeled targets (antigen or antibody) against corresponding immobilized antibody or antigen. To detect the antigen in competitive ELISA, an enzyme-labeled antigen is used to compete with the target antigens against the immobilized antibody (Fig. 2b). Hence, the higher the amount of antigen in the sample, the lower the amount of enzyme-labeled antigen that binds to the antibody. That is, with an increasing amount of target antigen, the signal decreases. In this case, competitive ELISA is suitable for measuring macromolecules only because a labeling enzyme is required to measure the antigen. If the antigen is a low molecular weight compound (e.g., hapten), resultant hapten–enzyme conjugates are not recognized by the immobilized antibody, leading to