A Review of Glass-Ionomer Cements for Clinical Dentistry.

Sidhu SK, Nicholson JW. · 2016

Read A Review of Glass-Ionomer Cements for Clinical Dentistry. by Sidhu SK, Nicholson JW. (2016) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc5040989.txt.

Introduction

Sharanbir K. Sidhu and John W. Nicholson review glass-ionomer cements for dentistry in the Journal of Functional Biomaterials in 2016. These filling materials set by an acid-base reaction in two to three minutes, forming a hard, tooth-colored solid. The review updates the literature on their structure, properties, and clinical uses, with weight on the last five years of work.

Once set, the cement is bioactive: it slowly forms an ion-exchange layer where it meets the tooth, and that layer gives it its strong, lasting grip. It also releases fluoride over long periods, a benefit dentists value even though the proof is not fully settled. Two modified forms are covered. Resin-modified versions match the original's physical strength but sit less well with living tissue. Glass carbomer is more brittle and weaker, and how its bioactivity compares is still unclear.

Catalog record

CREATORSidhu SK, Nicholson JW.
YEAR2016
COLLECTIONPAPERS
FORMATTXT
FILE SIZE54 KB
LICENSECC BY 4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/articles/PMC5040989

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

A Review of Glass-Ionomer Cements for Clinical Dentistry By Sharanbir K. Sidhu, John W. Nicholson, James Kit-hon Tsoi Published in: Journal of Functional Biomaterials DOI: 10.3390/jfb7030016 ABSTRACT This article is an updated review of the published literature on glass-ionomer cements and covers their structure, properties and clinical uses within dentistry, with an emphasis on findings from the last five years or so. Glass-ionomers are shown to set by an acid-base reaction within 2–3 min and to form hard, reasonably strong materials with acceptable appearance. They release fluoride and are bioactive, so that they gradually develop a strong, durable interfacial ion-exchange layer at the interface with the tooth, which is responsible for their adhesion. Modified forms of glass-ionomers, namely resin-modified glass-ionomers and glass carbomer, are also described and their properties and applications covered. Physical properties of the resin-modified glass-ionomers are shown to be good, and comparable with those of conventional glass-ionomers, but biocompatibility is somewhat compromised by the presence of the resin component, 2 hydroxyethyl methacrylate. Properties of glass carbomer appear to be slightly inferior to those of the best modern conventional glass-ionomers, and there is not yet sufficient information to determine how their bioactivity compares, although they have been formulated to enhance this particular feature. 1. INTRODUCTION Glass-ionomer cements belong to the class of materials known as acid-base cements. They are based on the product of reaction of weak polymeric acids with powdered glasses of basic character [1]. Setting occurs in concentrated solutions in water and the final structure contains a substantial amount of unreacted glass which acts as filler to reinforce the set cement. The term “glass-ionomer” was applied to them in the earliest publication [2], but is not strictly correct. The proper name for them, according to the International Organization for Standardization, ISO, is “glass polyalkenoate cement” [3], but the term “glass-ionomer” (including the hyphen) is recognised as an acceptable trivial name [4], and is widely used within the dental profession. 2. COMPOSITION There are three essential ingredients to a glass-ionomer cement, namely polymeric water-soluble acid, basic (ion-leachable) glass, and water [4]. These are commonly presented as an aqueous solution of polymeric acid and a finely divided glass powder, which are mixed by an appropriate method to form a viscous paste that sets rapidly. However, alternative formulations exist which range from both the acid and the glass being present in the powder, and pure water being added to cause setting, to formulations in which some of the acid is blended with the glass powder and the rest is present in a dilute solution in water. This solution is used as the liquid component in forming the paste for setting. The effect of these differences is not clear, because these formulations are proprietary, so that the exact amount of each component is not widely known. However, there appears to be no obvious effect on the final properties of presenting these materials with the components distributed differently between the powder and aqueous phases. Glass-ionomer cements can be mixed using a spatula on a pad or glass block, so-called hand-mixing. The material can also be presented in a bespoke capsule, separated by a membrane. The membrane is broken immediately before mixing, and the capsule is vibrated rapidly in a specially designed auto-mixer. This mixes the cement after which the freshly-formed paste is extruded from the capsule and used for intra-oral application. Where a single brand is available as both a hand-mixed and capsulated version, the two types of cement have to be formulated differently. A cement paste that sets in a satisfactory time when hand-mixed sets far too rapidly when subject to vibratory mixing. As a result, formulations for capsulation have to be less reactive than those for hand-mixing, and they rely on the accelerating effect of auto-mixing to give them satisfactory working and setting times. 3. POLYMERIC ACIDS The polymers used in glass-ionomer cements are polyalkenoic acids, either homopolymer poly(acrylic acid) or the 2:1 copolymer of acrylic acid and maleic acid. Poly(vinyl phosphonic acid) has been studied as a potential cement former [5], but its practical use is restricted to a single brand, where it is used in a mixture with poly(acrylic acid) and effectively acts as a setting rate modifier [6]. There is confusion in the literature about which polymers are used in glass-ionomer cements. This is because early research studied a range of mono-, di- and tri-carboxylic acid monomers in polymers for cement formation, including itaconic and tricarballylic acid [7]. This has led some authors to assume that these substances must be used in practical cements. However, this is not the case, and commercial cements use either the homopolymer or copolymer of acrylic acid. The polymer influences the properties of the glass-ionomer cement formed from them. High molecular weights increase the strength of the set cement, but solutions of high molecular weight polymers have high viscosities, making them difficult to mix. Molecular weights are therefore chosen to balance these competing effects. Optimum properties are said to be achieved with average molecular weights of 11,000 (number average) and 52,000 (mass average) [8]. These values give a polydispersity of 4.7 [8]. Cements prepared from homopolymers of acrylic acid show increases in compressive strength in the first 4–6 weeks. On the other hand, cements made from acrylic-maleic acid copolymers show an increase in compressive strength up to a point, but then there is a decline before an equilibrium value is reached. Compressive strength is not a fundamental property of materials, because compression causes a specimen to fracture in complex ways in directions approximately at right angles to the compressive force. However, these alterations in measured compressive strength indicate that the material continues to undergo slow changes over time. In particular, this reduction has been attribute to the higher crosslink density that develops within copolymer cements compared with cements based on acrylic acid homopolymer [9]. In clinical use, however, this difference between the homopolymer and copolymer cements does not seem important and there is no evidence that cements made from acrylic/maleic acid copolymer are less satisfactory in service. 4. GLASSES It is vital that glasses for ionomer cements should be basic, i.e., capable of reacting with an acid to form a salt. In principle, several different glass compositions can be prepared that fulfil this requirement but in practice, only alumino-silicate glasses, with fluoride and phosphate additions, are fully satisfactory. Commercial glasses for glass-ionomer cements are typically based on calcium compounds, with some extra sodium. There are also materials in which calcium has been substituted by strontium. Ionomer glasses owe their basic character to the fact that both alumina and silica are used in their preparation. Glasses based on silica alone lack reactivity and also basicity, because their structure contains mainly SiO4 tetrahedra linked at the corners to form chains that carry no charge. When alumina is added, the aluminium is forced to adopt a similar 4-fold tetrahedral geometry to silicon, i.e. AlO4 tetrahedra. As aluminium carries a formal 3+ charge, it does not counteract the effect of the negatively changed oxygens as effectively as silicon, with its formal 4+ charge. To balance this, extra cations such as Na+ and Ca2+ (or Sr2+) have to be present. These create basic character, and make