Which QT Correction Formulae to Use for QT Monitoring?

Vandenberk B, Vandael E, Robyns T, Vandenberghe J, Garweg C, Foulon V, Ector J, Willems R. · 2016

Read Which QT Correction Formulae to Use for QT Monitoring? by Vandenberk B, Vandael E, Robyns T, Vandenberghe J, Garweg C, Foulon V, Ector J, Willems R. (2016) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc4937268.txt.

Description

Bert Vandenberk and seven co-authors ask which formula best corrects the QT interval on a heart tracing. Their study appeared in the Journal of the American Heart Association in 2016. The QT interval must be adjusted for heart rate before doctors can judge drug risk. Many formulas exist, and hospitals need one for automatic monitoring in electronic records. The team tested five formulas on tracings from 6,609 patients at a hospital in Leuven, Belgium.

Fridericia and Framingham corrected best, while Bazett, the most used formula, performed worst. In healthy patients its upper normal limits sat above current clinical standards. In survival models, the Framingham version flagged risk of death most strongly. The authors question whether Bazett should stay the clinical default. They argue switching the standard formula would sharpen risk checks for patients on drugs that stretch the QT interval.

Catalog record

CREATORVandenberk B, Vandael E, Robyns T, Vandenberghe J, Garweg C, Foulon V, Ector J, Willems R.
YEAR2016
COLLECTIONPAPERS
FORMATTXT
FILE SIZE36 KB
LICENSECC BY 4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/articles/PMC4937268