Simultaneous multislice (SMS) imaging techniques.
Barth M, Breuer F, Koopmans PJ, Norris DG, Poser BA. · 2016
Read Simultaneous multislice (SMS) imaging techniques. by Barth M, Breuer F, Koopmans PJ, Norris DG, Poser BA. (2016) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc4915494.txt.
Introduction
Markus Barth and co-authors reviewed simultaneous multislice imaging in 2016, a method that speeds magnetic resonance scans. The trick excites several slices at once and unmixes them with parallel reconstruction. Speed gain equals the number of slices taken together, with only a small signal cost, unlike in-plane speedups.
Full gain holds at the fixed echo times that many brain scan types require. Some versions also cut the radio energy soaked into tissue. Faster scans mean less motion blur, more subjects per day, and finer time detail in brain activity studies. The review covers design choices, reconstruction routes, and artifacts, a field guide as the method moves into routine scanners.
Catalog record
| CREATOR | Barth M, Breuer F, Koopmans PJ, Norris DG, Poser BA. |
|---|---|
| YEAR | 2016 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 102 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Simultaneous multislice (SMS) imaging techniques By Markus Barth, Felix Breuer, Peter J Koopmans, David G Norris, Benedikt A Poser Published in: Magnetic Resonance in Medicine DOI: 10.1002/mrm.25897 ABSTRACT Abstract Simultaneous multislice imaging (SMS) using parallel image reconstruction has rapidly advanced to become a major imaging technique. The primary benefit is an acceleration in data acquisition that is equal to the number of simultaneously excited slices. Unlike in‐plane parallel imaging this can have only a marginal intrinsic signal‐to‐noise ratio penalty, and the full acceleration is attainable at fixed echo time, as is required for many echo planar imaging applications. Furthermore, for some implementations SMS techniques can reduce radiofrequency (RF) power deposition. In this review the current state of the art of SMS imaging is presented. In the Introduction, a historical overview is given of the history of SMS excitation in MRI. The following section on RF pulses gives both the theoretical background and practical application. The section on encoding and reconstruction shows how the collapsed multislice images can be disentangled by means of the transmitter pulse phase, gradient pulses, and most importantly using multichannel receiver coils. The relationship between classic parallel imaging techniques and SMS reconstruction methods is explored. The subsequent section describes the practical implementation, including the acquisition of reference data, and slice cross‐talk. Published applications of SMS imaging are then reviewed, and the article concludes with an outlook and perspective of SMS imaging. Magn Reson Med 75:63–81, 2016. © 2015 The Authors. Magnetic Resonance in Medicine Published by Wiley Periodicals, Inc. on behalf of International Society of Medicine in Resonance. Keywords: simultaneous multislice imaging, multiband imaging, fast imaging INTRODUCTION The possible advantages of simultaneously exciting and imaging several slices were realized early in the development of MRI 1. Already in 1980, simultaneous multislice (SMS) excitation was proposed as a method of improving the efficiency of line‐scan imaging techniques 1. Improved understanding of the physics of slice selective excitation led Müller 2 to propose the application of the Fourier shift theorem to generate the radiofrequency (RF) pulses necessary for SMS excitation. At a time in which single channel RF coils were almost universally used for MR signal reception the main possibility open to these early workers for disentangling the superposed signals from the acquired lines 1 or slices 2 was the phase manipulation of the signal. Initially schemes such as Hadamard encoding were used 1, 3, but to disentangle the signals from N slices, the imaging experiment must be repeated N times, with a different phase pattern for each excited slice. The use of such add/subtract schemes makes the experiment vulnerable to the effects of motion and other system instabilities; furthermore, the acquisition durations become quite long. The use of Hadamard encoding was thus more attractive for spectroscopy than imaging, as the extra acquisitions necessitated generally would not exceed the number of averages required to achieve sufficient sensitivity 4, 5. Apart from using the phase some early work also showed that it is possible to use frequency‐encoding to disentangle the slices 6. This, however, has two obvious disadvantages: the frequency‐encoding direction is then oblique to the slice axis so that the voxels have a parallelogram cross‐section, and the number of data points along the frequency‐encoding direction must also be increased to accommodate the data from all the slices, thus increasing the readout duration. An important development, that indeed foreshadowed many of those made in recent years, was the introduction of the POMP technique [phase offset multiplanar volume imaging 7]. Here multiple slices were excited, but rather than manipulating the phase of the entire slice, as in the Hadamard based techniques, each acquired slice had a unique phase gradient in k‐space that was imposed by the phase of the applied RF pulses. For example, in a two slice experiment one slice could have no phase variation, and the phase of the other would alternate between 0 and π for successive k‐space lines. This latter slice would, hence, be shifted by half a field of view (FOV) in image space, so that if the FOV in the phase‐encoding direction were doubled then the two slices would not be superimposed and could be viewed separately. In both Hadamard and POMP imaging it was clear that the simultaneous detection of signals from N slices resulted in an increase in sensitivity of √N relative to the sequential acquisition of data from the same number of slices, but in no net reduction in acquisition time. Furthermore, it was inherent to the summation principle of the RF pulses used, that the power deposition would increase linearly with the number of excited slices, and if the pulses had identical phase then the peak power would increase with N2. The peak power could, however, be reduced by finding an optimum phase variation between the pulses 8. The revolution in imaging acquisition brought about by the introduction of parallel imaging techniques 9, 10, 11 at the turn of the millennium had an immediate impact on simultaneous multislice imaging. The possibility of disentangling simultaneously excited slices by means of the coil sensitivity profiles and, thereby dramatically reducing acquisition times, was initially demonstrated by Larkman et al in 2001 12 (Fig. 1). However, this idea was only followed up by a relatively small community, and did not attract widespread attention for almost a decade. Contributing factors to this slow development were probably the relatively late availability of receiver coils with a coil distribution along the z‐axis, which is necessary to accelerate axial acquisitions; and the lack of an obvious application. Despite this relative lack of initial interest, important progress was made during these years, and special attention should be given to the CAIPIRINHA (controlled aliasing in parallel imaging results in higher acceleration) technique 13, which in a similar manner to POMP uses the phase of the RF pulses to shift the position of adjacent slices in image space. This makes it far easier to disentangle adjacent slices where the coil sensitivity profiles are similar; hence, the gap between slices can be reduced. [Figure: First ever in vivo SMS images obtained from the leg of a healthy volunteer using a four element coil array. The top row shows the images obtained from each coil, the bottom row shows the disentangled slices using a SENSE reconstruction. Figure taken with kind permission from Larkman et al 12.] For most pulse sequences, the accelerations achievable by implementing standard parallel imaging and SMS imaging are similar, but the implementation of SMS is more demanding as higher power RF pulses have to be incorporated into the imaging sequence. A significant advantage of SMS is that it does not directly cause a reduction in sensitivity, whereas this is inherent to the reduction in the number of phase‐encoding steps acquired in standard parallel imaging methods. For echo planar imaging (EPI) in particular, the benefits of SMS are qualitatively different than for standard parallel imaging. The latter reduces the duration of the EPI readout; hence, both the distortion and the SNR are correspondingly reduced. SMS leads to a reduction in acquisition time by a factor N, with no impact on distortion or SNR. Although an earlier abstract had demonstrated the combination of EPI with SMS 14, it was the subsequent publications