Surface Modifications and Their Effects on Titanium Dental Implants.

Jemat A, Ghazali MJ, Razali M, Otsuka Y, Otsuka Y. · 2015

Read Surface Modifications and Their Effects on Titanium Dental Implants. by Jemat A, Ghazali MJ, Razali M, Otsuka Y, Otsuka Y. (2015) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc4575991.txt.

Introduction

A. Jemat, M. J. Ghazali, M. Razali, and Y. Otsuka review surface treatments for titanium dental implants, in BioMed Research International in 2015. A dental implant succeeds when jaw bone grows tight against it, a bond called osseointegration. The metal's surface decides much of that bond, and makers treat it by adding coatings or etching material away.

Drawing on 18 years of published work, the review compares methods head-to-head. Surface roughness emerged as a key driver of bone contact, cell growth, and resistance to twisting out, even though titanium's strength was never in doubt. Acid-etched surfaces and applied coatings performed best overall. Marrying good roughness with titanium's mechanical strength, the authors conclude, is the recipe for lasting implants.

Catalog record

CREATORJemat A, Ghazali MJ, Razali M, Otsuka Y, Otsuka Y.
YEAR2015
COLLECTIONPAPERS
FORMATTXT
FILE SIZE47 KB
LICENSECC BY 4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/articles/PMC4575991

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Surface Modifications and Their Effects on Titanium Dental Implants By A. Jemat, M. J. Ghazali, M. Razali, Y. Otsuka Published in: BioMed Research International DOI: 10.1155/2015/791725 ABSTRACT This review covers several basic methodologies of surface treatment and their effects on titanium (Ti) implants. The importance of each treatment and its effects will be discussed in detail in order to compare their effectiveness in promoting osseointegration. Published literature for the last 18 years was selected with the use of keywords like titanium dental implant, surface roughness, coating, and osseointegration. Significant surface roughness played an important role in providing effective surface for bone implant contact, cell proliferation, and removal torque, despite having good mechanical properties. Overall, published studies indicated that an acid etched surface-modified and a coating application on commercial pure titanium implant was most preferable in producing the good surface roughness. Thus, a combination of a good surface roughness and mechanical properties of titanium could lead to successful dental implants. 1. INTRODUCTION Surface treatments are normally carried out to modify yet maintain desirable properties of the substrate materials especially in the dental implant industry. The surface area can be increased remarkably by using proper modification techniques, either by addition or subtraction procedures [1, 2]. A surface treatment can also be classified into mechanical, chemical, and physical methods. In dental implant, the surface treatment is used to modify the surface topography and surface energy, resulting in an improved wettability [3–5], increased cell proliferation and growth [3], and accelerated osseointegration process [6]. The quality of dental implant depends on the properties of the surface. In order to have good interaction of the tissue and osseointegration, materials' biocompatibility and roughness of the surface played an important role. Goyal and coworkers [7] observed that the increased roughness can simultaneously increase the surface area of the implant, improve cell migration and attachment to implant, and enhance osseointegration process. Past literature has revealed most of the surface treatments able to brings a good effect to the dental implants [3–6]. Coating is proved to increase the surface area of the implants substantially [8]. The surface treated with plasma sprayed titanium exhibits the highest value of the surface roughness (3.43 ± 0.63 μm) compared to machined surface (0.15 ± 0.04 μm) [9]. The healing period was enhanced with hydroxyapatite (HA) coating compared to untreated one [10]. The behavior of modified surface on cells culture studies has revealed that an acid etched zirconia implant surface shows a significant improvement in cell proliferation, except for bone attachment and adhesion on the first day of culture [11–13]. In the study by Parsikia et al. [14], the commercially pure titanium surface was blasted followed by two-step chemical treatment (acid-alkali) resulting in optimized surface topography. The cell bioactivity was improved and expected to have good osseointegration at early stage. Furthermore, a rougher titanium surface promotes shorter healing process [15] than the smoother surfaces. Thus, the surface treatment is used not only to maintain the existing properties of the implants but also to enhance several behaviours as required by dental applications particularly in improving the healing process. 2. BACKGROUND 2.1. Titanium Implant Titanium is the material of choice for dental implant as its properties met the most important requirements such as excellent biocompatibility [16], corrosion resistance, high strength, and relatively low modulus of elasticity [17], good formability, and machinability. Additionally, surface modifications are being utilised on implant surfaces, mainly to improve wettability, cell-implant adhesion and attachment, cell proliferation, and osseointegration, and thus faster healing and shorter treatment duration. As a result, many research works have been carried out to improve surface modifications on existing implants to achieve the desired biological responses. The surface topography has also been manipulated such as acid etching and blasting [18] onto the surface to get a better topographies which consequently bring better roughness. In the case of the mechanisms, the roughness of the titanium implants was considered to be one of the significant parameters that affect the rate and the quality of osseointegration [15, 18, 19]. 2.2. Biocompatibility of Titanium and Its Alloys Materials compatibility is the most important issue to be considered for a successful dental implantation. Titanium and its alloys are well known as materials that are well tolerated by living tissues and capable of promoting osseointegration [20]. Ideally, the modification of the implant surface was proposed to enhance osseointegration between materials and bone tissue. The surfaces of materials after treatment should be able to interact with the surrounding tissue to induce direct contact of bone to implant. Kokubo treatment, also known as simulated body fluid (SBF), is a chemical method for inducing or determining a level of biocompatibilities property of dental materials that was established in 1991 [21]. SBF can be described as a solution with ion concentration similar to human blood plasma (see Table 1), kept under mild conditions of pH and identical physiological temperature [21]. The history of SBF usage for apatite formation is shown in Figure 1 [21–25]. In early 1980, Ogino and coworkers [22] have found silicon dioxide (SiO2) layer and calcium phosphate (CaP) formed on a Bioglass which allows bonding to living bone. In 1990, Kokubo et al. [24] have stated that the formation of apatite is an essential for osseointegration between implant surface and living bone. The full preparation of SBF has been reported in 1995 by Cho et al. [25]. In vivo and in vitro bioactivity of a material can be predicted from the apatite formation on its surface in SBF [26]. Surface conditions, such as surface roughness, surface charge, surface energy, and chemical composition, have important influences on the osseointegration process. Therefore, modifying titanium implant surface seems to be a promising way to achieve stronger and faster osseointegration of the implants and also promoted shorter healing times from implant placement to restoration [27]. 2.3. Surface Treatment Recently, many works have been carried out on surface treated commercial titanium implants to enhance the osseointegration function (references). By increasing the surface roughness, an increase in the osseointegration rate and the biomechanical fixation of titanium implants have been observed [27, 28]. The implant modifications can be achieved either by additive or subtractive methods. The additive methods employed the treatment in which other materials are added to the surface, either superficial or integrated, categorized into coating and impregnation, respectively. While impregnation implies that the material/chemical agent is fully integrated into the titanium core, such as calcium phosphate crystals within TiO2 layer or incorporation of fluoride ions to surface, the coating on the other hand is addition of material/agent of various thicknesses superficially on the surface of core material. The coating techniques can include titanium plasma spraying (TPS), plasma sprayed hydroxyapatite (HA) coating, alumina coating, and biomimetic calcium phosphate (CaP) coating. Meanwhile, the subtractive techniques are the procedure to either remove the layer of core material or plastically deform the superficial surface and thus roughen the surface of core material. The common subtractive techniques are large-grit sands or ceramic particle blasts, acid etch, and anodization [19]. The removal of surface material by mechanical methods involved shaping/removing, grinding, machining, or grit blasting via physical force. A chemical treatment, either by using acids or using alkali solution of titanium alloys in particular, is normally performed not

Read the complete text