Metrics for evaluating 3D medical image segmentation: analysis, selection, and tool.

Taha AA, Hanbury A. · 2015

Read Metrics for evaluating 3D medical image segmentation: analysis, selection, and tool. by Taha AA, Hanbury A. (2015) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc4533825.txt.

Introduction

Abdel Aziz Taha and Allan Hanbury tackle how to grade 3D medical image outlines, in BMC Medical Imaging in 2015. Segmentation marks out organs or tumors in scans, and progress in the field depends on scoring those outlines against truth. Scores clash in practice: the same metric may carry several definitions, and old code crawls on whole-body scans.

The pair review 20 evaluation metrics drawn from the literature and give each a fuzzy form, for outlines that assign partial membership rather than hard borders. They explain each metric's traits to guide sound choices. Their free tool computes all 20 fast and with low memory, even on very large volumes such as whole-body MRI or CT.

Catalog record

CREATORTaha AA, Hanbury A.
YEAR2015
COLLECTIONPAPERS
FORMATTXT
FILE SIZE137 KB
LICENSECC BY 4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/articles/PMC4533825

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Metrics for evaluating 3D medical image segmentation: analysis, selection, and tool By Abdel Aziz Taha, Allan Hanbury Published in: BMC Medical Imaging DOI: 10.1186/s12880-015-0068-x ABSTRACT Background Medical Image segmentation is an important image processing step. Comparing images to evaluate the quality of segmentation is an essential part of measuring progress in this research area. Some of the challenges in evaluating medical segmentation are: metric selection, the use in the literature of multiple definitions for certain metrics, inefficiency of the metric calculation implementations leading to difficulties with large volumes, and lack of support for fuzzy segmentation by existing metrics. Result First we present an overview of 20 evaluation metrics selected based on a comprehensive literature review. For fuzzy segmentation, which shows the level of membership of each voxel to multiple classes, fuzzy definitions of all metrics are provided. We present a discussion about metric properties to provide a guide for selecting evaluation metrics. Finally, we propose an efficient evaluation tool implementing the 20 selected metrics. The tool is optimized to perform efficiently in terms of speed and required memory, also if the image size is extremely large as in the case of whole body MRI or CT volume segmentation. An implementation of this tool is available as an open source project. Conclusion We propose an efficient evaluation tool for 3D medical image segmentation using 20 evaluation metrics and provide guidelines for selecting a subset of these metrics that is suitable for the data and the segmentation task. BACKGROUND Medical 3D image segmentation is an important image processing step in medical image analysis. Segmentation methods with high precision (including high reproducibility) and low bias are a main goal in surgical planning because they directly impact the results, e.g. the detection and monitoring of tumor progress [1–3]. Warfield et al. [4] denoted the clinical importance of better characterization of white matter changes in the brain tissue and showed that particular change patterns in the white matter are associated with some brain diseases. Accurately recognizing the change patterns is of great value for early diagnosis and efficient monitoring of diseases. Therefore, assessing the accuracy and the quality of segmentation algorithms is of great importance. Medical 3D images are defined on a 3D grid that can have different sizes depending on the body parts imaged and the resolution. The grid size is given as (w×h×d) denoting the width, height, and depth of the 3D image. Each 3D point on the grid is called a voxel. Given an anatomic feature, a binary segmentation can be seen as a partition that classifies the voxels of an image according to whether they are part or not of this feature. Examples of anatomic features are white matter, gray matter, lesions of the brain, body organs and tumors. Segmentation evaluation is the task of comparing two segmentations by measuring the distance or similarity between them, where one is the segmentation to be evaluated and the other is the corresponding ground truth segmentation. Medical segmentations are often fuzzy meaning that voxels have a grade of membership in [0,1]. This is e.g. the case when the underlying segmentation is the result of averaging different segmentations of the same structure annotated by different annotators. Here, segmentations can be thought of as probabilities of voxels belonging to particular classes. One way of evaluating fuzzy segmentations is to threshold the probabilities at a particular value to get binary representations that can be evaluated as crisp segmentations. However, thresholding is just a workaround that provides a coarse estimation and is not always satisfactory. Furthermore, there is still the challenge of selecting the threshold because the evaluation results depend on the selection. This is the motivation for providing metrics that are capable of comparing fuzzy segmentations without loss of information. Note that there is another common interpretation of fuzzy segmentation as partial volume, where the voxel value represents the voxel fraction that belongs to the class. The fuzzy metric definitions provided in this paper can be applied for this interpretation as well. There are different quality aspects in 3D medical image segmentation according to which types of segmentation errors can be defined. Metrics are expected to indicate some or all of these errors, depending on the data and the segmentation task. Based on four basic types of errors (added regions, added background, inside holes and border holes), Shi et al. [5] described four types of image segmentation errors, namely the quantity (number of segmented objects), the area of the segmented objects, the contour (degree of boundary match), and the content (existence of inside holes and boundary holes in the segmented region). Fenster et al. [6] categorized the requirements of medical segmentation evaluation into accuracy (the degree to which the segmentation results agree with the ground truth segmentation), the precision as a measure of repeatability, and the efficiency which is mostly related with time. Under the first category (accuracy), they mentioned two quality aspects, namely the delineation of the boundary (contour) and the size (volume of the segmented object). The alignment, which denotes the general position of the segmented object, is another quality aspect, which could be of more importance than the size and the contour when the segmented objects are very small. Metric sensitivities are another challenge in defining metrics. Sensitivity to particular properties could prevent the discovery of particular errors or lead to over- or underestimating them. Metrics can be sensitive to outliers (additional small segmented objects outside the main object), class imbalance (size of the segmented object relative to the background), number of segmented objects, etc. Another type of sensitivity is the inability to correctly deal with agreement caused by chance. This is related to the baseline value of the metric, which should ideally be zero when the segmentation is done at random, indicating no similarity [7]. There is a need for a standard evaluation tool for medical image segmentation which standardizes not only the metrics to be used, but also the definition of each metric. To illustrate this importance, Section “Multiple definition of metrics in the literature” shows examples of metrics with more than one definition in the literature leading to different values, but each of them is used under the same name. In the text retrieval domain, the TREC_EVAL tool1 provides a standardization of evaluation that avoids such confusion and misinterpretation and provides a standard reference to compare text retrieval algorithms. The medical imaging domain lacks such a widely applied instrument. Gerig et al. [8] proposed a tool (Valmet) for evaluation of medical volume segmentation. In this tool only five metrics are implemented. There are important metrics, like information theoretical metrics as well as some statistical metrics like Mahalanobis distance, and metrics with chance correction like Kappa and adjusted Rand index, that are not implemented in the Valmet evaluation tool. Furthermore, this tool doesn’t provide support for fuzzy segmentation. The ITK Library2 provides a software layer that supports medical imaging tasks including segmentation and registration. The ITK Library provides evaluation metrics that are mostly based on distance transform filters [9]. However, this implementation has the following shortcomings: First, the ITK Library doesn’t implement all relevant metrics needed for evaluating medical segmentation. Second, since most of the metrics are based on distance transform filters,