Versatile sample environments and automation for biological solution X-ray scattering experiments at the P12 beamline (PETRA III, DESY).
Blanchet CE, Spilotros A, Schwemmer F, Graewert MA, Kikhney A, Jeffries CM, Franke D, Mark D, Zengerle R, Cipriani F, Fiedler S, Roessle M, Svergun DI. · 2015
Read Versatile sample environments and automation for biological solution X-ray scattering experiments at the P12 beamline (PETRA III, DESY). by Blanchet CE, Spilotros A, Schwemmer F, Graewert MA, Kikhney A, Jeffries CM, Franke D, Mark D, Zengerle R, Cipriani F, Fiedler S, Roessle M, Svergun DI. (2015) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc4379436.txt.
Introduction
Clement Blanchet and a team of co-authors described the sample systems at a biological X-ray scattering station, in the Journal of Applied Crystallography in 2015. Small-angle X-ray scattering reveals the overall shape of molecules in solution, at scales from nanometers up. The P12 beamline at the PETRA III synchrotron in Hamburg, run by the European Molecular Biology Laboratory, is built for such work on biological samples, which are often scarce and fragile.
The station pairs bright X-rays with automated hardware and software, so samples are loaded, measured, and processed with little hand work. Sample holders cover many conditions, letting users vary temperature and other settings in one visit. Automation keeps data collection fast and uniform, and built-in processing gives quick feedback on data quality. The design aims to let visiting biologists run complex experiments without being scattering specialists.
Catalog record
| CREATOR | Blanchet CE, Spilotros A, Schwemmer F, Graewert MA, Kikhney A, Jeffries CM, Franke D, Mark D, Zengerle R, Cipriani F, Fiedler S, Roessle M, Svergun DI. |
|---|---|
| YEAR | 2015 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 57 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Versatile sample environments and automation for biological solution X-ray scattering experiments at the P12 beamline (PETRA III, DESY) By Clement E Blanchet, Alessandro Spilotros, Frank Schwemmer, Melissa A Graewert, Alexey Kikhney, Cy M Jeffries, Daniel Franke, Daniel Mark, Roland Zengerle, Florent Cipriani, Stefan Fiedler, Manfred Roessle Published in: Journal of Applied Crystallography DOI: 10.1107/S160057671500254X ABSTRACT An integrated environment for biological small-angle X-ray scattering (BioSAXS) at the high-brilliance P12 synchrotron beamline of the EMBL (DESY, Hamburg) allows for a broad range of solution scattering experiments. Automated hardware and software systems have been designed to ensure that data collection and processing are efficient, streamlined and user friendly. Keywords: biological small-angle X-ray scattering, high-brilliance P12 synchrotron beamline, automated hardware and software systems INTRODUCTION Small-angle X-ray scattering (SAXS) is an experimental technique that is used to extract global structural parameters and shape information in the scale ranging from nanometres to a micrometre. Every material with inhomogeneous electron density can be probed using SAXS, which is routinely employed to probe the structures of polymers (Chu & Hsiao, 2001 ▶), tissues (Paris et al., 2000 ▶; Fernández et al., 2002 ▶), alloys and ceramics (Fratzl, 2003 ▶) as well as biological macromolecules and nanocomposites in solution (Blanchet & Svergun, 2013 ▶; Spilotros & Svergun, 2014 ▶). The scattering from solutions is usually isotropic owing to the random position and orientation of particles, and the scattering intensity I(s) is presented as a function of momentum transfer s = 4πsinθ/λ, where 2θ is the scattering angle and λ is the wavelength of the X-rays. Biomacromolecular solution SAXS presents unique experimental challenges. Proteins, nucleic acids, lipids and carbohydrates have low contrasts relative to their typically aqueous solvents (i.e. the difference in electron density between the dissolved particles and the solvent is small). Consequently, the solute scattering intensities obtained after subtraction of the solvent scattering are generally very weak. Moreover, pure and stable biological samples can be difficult to produce in quantity, and these often precious samples can be potentially affected by X-ray radiation damage, resulting in the production of aggregates that spoil measurements. Dedicated synchrotron BioSAXS beamlines must take these complications into account and balance the advantages afforded by high-brilliance sources that open new avenues of structural investigation – such as high-throughput screening operations, in-line component separation, real-time kinetics and microfluidics – with the constraints imposed by the fragility and availability of biological samples. Recently developed approaches to extract rich structural information from SAXS data on a broad range of molecule sizes and experimental conditions have led to a dramatically increased popularity of solution SAXS as both a standalone and complementary tool for structural biologists (Lipfert & Doniach, 2007 ▶; Graewert & Svergun, 2013 ▶). Several beamlines partly or entirely dedicated to BioSAXS have been built over the past few years (David & Pérez, 2009 ▶; Classen et al., 2010 ▶; Blanchet et al., 2012 ▶; Nielsen et al., 2012 ▶; Kirby et al., 2013 ▶; Labrador et al., 2013 ▶; Pernot et al., 2013 ▶). Many of these instruments have been engineered to optimize the collection of weak scattering signals in combination with new sample handling environments and devices for specialized experiments. The EMBL X33 beamline located on the DORIS III storage ring (DESY, Hamburg) was one of the first SAXS beamlines entirely dedicated to the analysis of biological macromolecules. The significant advances in hardware and in software made at X33 (Roessle et al., 2007 ▶; Blanchet et al., 2012 ▶) have been transferred to the new P12 BioSAXS beamline at the storage ring PETRA III (synchrotron DESY, Hamburg). The beamline constructed and run by EMBL in Hamburg with a Collaborative Access Group contribution from the Helmholtz-Zentrum Geesthacht (HZG) has now been in full operation since 2013 with an extensive user program. P12 utilizes a focused monochromatic X-ray beam from an undulator source and offers high brilliance and reduced background coupled with automated sample handling, data collection and processing protocols for a variety of solution scattering experiments. This manuscript is devoted to describing the automation and possibilities available at P12 for performing various types of biological solution scattering experiments. In addition to a fully automated and remote high-throughput operation with a robotic sample changer, sample environments and control systems have been developed for in-line size-exclusion chromatography component separation with additional detectors, as well as a stop-and-flow device for fast-time kinetics. A novel microfluidic system for ultra-low sample volume handling and mixing, the SAXS disc, has been developed for concentration, additive or stability screening. P12 BEAMLINE OVERVIEW In this section, we shall give a brief summary of the design and of the relevant characteristics of P12, as well as presenting more specific developments making the beamline especially suitable for the solution scattering experiments. Monochromatic X-rays of the P12 BioSAXS beamline are sourced from the controllable-gap low-divergence U29 undulator of PETRA III. A double-crystal Si(111) monochomator allows tuneable energy selections between 4 and 20 keV (λ = 0.06–0.3 nm), with a typical default energy of 10 keV (λ = 0.124 nm) used for most operations. Adaptive bimorph mirrors in a Kirkpatrick–Baez geometry combined with a three-pair slit collimation produce a close to one-to-one optics that conserves the low divergence of the source, delivering an intense (1013 photons s−1) highly focused small beam to the sample position (120 × 200 µm full width at half-maximum). The entire beamline (source-to-detector length of 83 m), including an adjustable detector tube (sample–detector distance of 1.6, 2.1, 3.1, 4.1 or 6.1 m; usually 3.1 m), remains under vacuum for standard quartz capillary sample cell measurements. Any nonstandard sample environment can be positioned into the beam using an in-air configuration, with Kapton sealing windows across an air gap of a few centimetres, aided by motorized x–y sample stages and an on-axis camera. For biological solution scattering experiments the fraction of photons scattered by the solutes is exceptionally low, of the order of 10−6 of the incident photons (Stuhrmann, 1980 ▶). In order to properly extract the weak scattering signal from the target of interest it is necessary that (a) the scattered photons are collected with a low-noise detector, (b) parasitic scattering from the optical components of the beamline is minimized, (c) the data are accurately normalized to the beam intensity and transmittance of the sample, and (d) means are available to reduce the effects of radiation damage. Below, solutions implemented at P12 to meet these requirements are briefly described. Detector 2.1. The P12 beamline is equipped with a hybrid photon-counting pixel detector (Henrich et al., 2009 ▶) having practically no detector readout noise, a high (20 bits) dynamic range and a short (few ms) readout time. The Pilatus 2M detector (Dectris), consisting of 1475 × 1679 pixel (172 × 172 µm) modular arrays with a total active area of 253.7 × 288.8 mm, is mounted on railings for motorized translation between the five positions spanning 1.6–6.1 m. The detector can be offset such that at the default position of 3.1 m, at an energy of 10 keV (λ = 0.124 nm), the SAXS data are recorded in the range s = 0.02–4.5 nm−1, corresponding to a real-space resolution of 300–1.5 nm. By varying the sample–detector distance and, if necessary, the beam energy momentum transfers down to