Vapors produced by electronic cigarettes and e-juices with flavorings induce toxicity, oxidative stress, and inflammatory response in lung epithelial cells and in mouse lung.

Lerner CA, Sundar IK, Yao H, Gerloff J, Ossip DJ, McIntosh S, Robinson R, Rahman I. · 2015

Read Vapors produced by electronic cigarettes and e-juices with flavorings induce toxicity, oxidative stress, and inflammatory response in lung epithelial cells and in mouse lung. by Lerner CA, Sundar IK, Yao H, Gerloff J, Ossip DJ, McIntosh S, Robinson R, Rahman I. (2015) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc4319729.txt.

Introduction

Chad A. Lerner and eight co-authors tested flavored e-cigarette vapors on lung cells and on mouse lungs. Their study appeared in PLoS ONE in 2015. Use of electronic cigarettes and flavored juices was climbing fast, while the harm those aerosols might do to airways had barely been studied.

The vapor carried oxidant reactivity, traced to the heating element and stronger with some flavors; unvaporized juices also showed oxidative power tied to their flavor additives. Lung epithelial cells exposed to the aerosols suffered cell damage, oxidative stress, and inflammatory signals, and mouse lungs showed the same pattern. The work treats flavorings as active ingredients in the health question, not as harmless extras.

Catalog record

CREATORLerner CA, Sundar IK, Yao H, Gerloff J, Ossip DJ, McIntosh S, Robinson R, Rahman I.
YEAR2015
COLLECTIONPAPERS
FORMATTXT
FILE SIZE71 KB
LICENSECC BY 4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/articles/PMC4319729

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Vapors Produced by Electronic Cigarettes and E-Juices with Flavorings Induce Toxicity, Oxidative Stress, and Inflammatory Response in Lung Epithelial Cells and in Mouse Lung By Chad A. Lerner, Isaac K. Sundar, Hongwei Yao, Janice Gerloff, Deborah J. Ossip, Scott McIntosh, Risa Robinson, Irfan Rahman, M. Firoze Khan Published in: PLoS ONE DOI: 10.1371/journal.pone.0116732 ABSTRACT Oxidative stress and inflammatory response are the key events in the pathogenesis of chronic airway diseases. The consumption of electronic cigarettes (e-cigs) with a variety of e-liquids/e-juices is alarmingly increasing without the unrealized potential harmful health effects. We hypothesized that electronic nicotine delivery systems (ENDS)/e-cigs pose health concerns due to oxidative toxicity and inflammatory response in lung cells exposed to their aerosols. The aerosols produced by vaporizing ENDS e-liquids exhibit oxidant reactivity suggesting oxidants or reactive oxygen species (OX/ROS) may be inhaled directly into the lung during a “vaping” session. These OX/ROS are generated through activation of the heating element which is affected by heating element status (new versus used), and occurs during the process of e-liquid vaporization. Unvaporized e-liquids were oxidative in a manner dependent on flavor additives, while flavors containing sweet or fruit flavors were stronger oxidizers than tobacco flavors. In light of OX/ROS generated in ENDS e-liquids and aerosols, the effects of ENDS aerosols on tissues and cells of the lung were measured. Exposure of human airway epithelial cells (H292) in an air-liquid interface to ENDS aerosols from a popular device resulted in increased secretion of inflammatory cytokines, such as IL-6 and IL-8. Furthermore, human lung fibroblasts exhibited stress and morphological change in response to treatment with ENDS/e-liquids. These cells also secrete increased IL-8 in response to a cinnamon flavored e-liquid and are susceptible to loss of cell viability by ENDS e-liquids. Finally, exposure of wild type C57BL/6J mice to aerosols produced from a popular e-cig increase pro-inflammatory cytokines and diminished lung glutathione levels which are critical in maintaining cellular redox balance. Thus, exposure to e-cig aerosols/juices incurs measurable oxidative and inflammatory responses in lung cells and tissues that could lead to unrealized health consequences. INTRODUCTION The consumption of electronic nicotine delivery systems (ENDS) and electronic cigarettes (e-cigs) is rising and currently scientific information necessary to inform the FDA and clinicians of potential health risks is lacking. Studies involving the effects of ENDS/e-cig liquids and aerosols on animal cells and tissues, in particular those of the lung, are lacking and the long-term outcome of chronic ENDS use is difficult to predict. Oxidative toxicity and inflammation are associated with increased risk of lung diseases caused by conventional tobacco products is well established [1]. However, there is no clear indication that inhaling aerosols from ENDS/e-cigs (as a cessation device) will allow a healthy outcome for users and furthermore, the manufactures that produce ENDS globally are not liable to disclose the materials and chemicals employed in their fabrication. Two independent studies have reported that certain flavored e-liquids exhibit differential in vitro cytotoxicity when applied directly to various cells independent of nicotine, suggesting potential toxicities are associated with flavor additives [2,3]. Other toxic chemicals including carcinogens which are not typically found in e-liquids may be released or generated from ENDS/e-cigs and have been detected at low levels in various ENDS aerosols [4–6]. Some of these toxicants may emanate from heated structural materials while drawing air through an ENDS device, but are also proposed to form during the vaporization process [7,8]. Specific particulates, heavy metals, and toxic carbonyls in ENDS/e-cig aerosols have recently been measured in e-cigs aerosols as well [5,7,9,10]. Despite limited evidence that ENDS/e-cigs pose a danger, there is debate as to whether meaningful comparisons exist between the health risks of those exposed to tobacco smoke and those exposed to aerosols generated by ENDS devices [11]. Many of the secondary compounds (polyaromatic hydrocarbons, PAHs, aldehydes, and carbonyls) identified in ENDS aerosols and replacement liquids (e-liquids) are considered low level, especially in comparison to levels measured in environmental tobacco/cigarette smoke [5–7,12,13]. Furthermore, the levels of toxic compounds identified in ENDS aerosols that primary users would be exposed to in a “vaping” session are also not expected to approach established threshold limit values for what is considered a health risk for by-standard exposure to these compounds in cigarette smoke (passive smoking/second hand smoke) [14]. However, oxidants/reactive oxygen species (OX/ROS) found in cigarette smoke and generated from tars are major contributors in mediating an inflammatory state, which have been implicated in the pathogenesis of diseases, such as chronic obstructive pulmonary disease (COPD) and lung cancer [15]. The presence or generation of OX/ROS associated with ENDS devices and e-liquids has yet to be evaluated and may pose a health risk that is underappreciated. There are approximately 1015 free radicals in a puff of conventional cigarette smoke in addition to heavy metals nanoparticles which have also recently been shown in e-cig aerosols to similar levels per “puff” [10,16]. Heavy metals may undergo redox cycling and alter the oxidation state of the cell by potentiating the production of ROS [17]. It is expected that OX/ROS in aerosols of ENDS/e-cigs will have an impact on cellular oxidative stress, redox imbalance, and lung inflammation, but this is still not clear in vitro in lung cells and in vivo in lungs. We hypothesized that electronic nicotine delivery systems (ENDS)/e-cigs induce oxidative toxicity and inflammatory response by generation of ROS and alteration in redox GSH levels in lung cells in vitro and in vivo in mouse lung exposed to their aerosols, respectively. We determined the source of oxidants produced from ENDS/e-cigs by a modified 2'-7'-dichlorodihydrofluorescein diacetate (DCFH-DA) fluorescein derived dye to detect OX/ROS reactivity in ENDS/e-cig aerosols and pre-vaporized e-liquids in a cell free system. We also evaluated cultured lung cells exposed to e-liquids or aerosols for cell toxicity, inflammation, and then extended our studies to a mouse model of e-cig aerosol exposure. By exposing wild-type (C57BL/6J) mice to e-cig aerosols, we examined the effect of short-term (3 days) exposure to e-cig aerosols on aspects of lung inflammation, oxidative stress, and redox physiology by measuring changes in glutathione levels. MATERIALS AND METHODS Ethics statement All experimental protocols were performed in accordance with the standards established by the United States Animal Welfare Act, as set forth by the National Institutes of Health guidelines. The research protocol for these studies was approved by the University of Rochester Committee on Animal Research. Materials Two ENDS devices were used. First, a refillable pen style ENDS (eGo Vision Spinner battery, China) and compatible clearomizer chamber (Anyvape, China) with 2.2 ohm heating element was purchased from local retailers (Fig. 1A). The clearomizer chamber can be easily filled with e-liquid of choice allowing liquid to continuously absorb into heating element wick. Refillable e-liquids (Table 1) for use with refillable ENDS were purchased from various local retailers. Second, is the Blu e-cigs where the cartomizer is manufactured to be disposable when the pre-loaded e-liquid is exhausted. The Blu e-cigs and disposable cartomizer cartridges were purchased from local retailers (Fig. 1A). [Figure: Refillable ENDS and Blu e-cigarettes.(A) Refillable ENDS and Blu e-cigarettes (B) Clearomizer removed, outer wick shown covering top of heating element coil (Upper panel). Used wick removed showing darkened region that contacted heating coil (Middle panel). Heating coil wrapped around second wick (Lower

Read the complete text