Tools for macromolecular model building and refinement into electron cryo-microscopy reconstructions.
Brown A, Long F, Nicholls RA, Toots J, Emsley P, Murshudov G. · 2015
Read Tools for macromolecular model building and refinement into electron cryo-microscopy reconstructions. by Brown A, Long F, Nicholls RA, Toots J, Emsley P, Murshudov G. (2015) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc4304694.txt.
Introduction
Alan Brown, Fei Long, Robert A Nicholls, Jaan Toots, Paul Emsley, and Garib Murshudov describe new tools for building atomic models into cryo-electron microscopy maps. Their paper appeared in Acta Crystallographica Section D in 2015. Cryo-EM had begun delivering near atomic views of large cell machines, but fitting and refining a model inside those maps lagged behind.
The tools extend the Coot and REFMAC programs long used in crystallography. They handle the quirks of EM maps, including local resolution changes and flexible fitting of model parts, with restraint libraries to keep chemistry sane. The paper is a practical account for structural biologists moving into the cryo-EM era, written by the teams behind the software.
Catalog record
| CREATOR | Brown A, Long F, Nicholls RA, Toots J, Emsley P, Murshudov G. |
|---|---|
| YEAR | 2015 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 75 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Tools for macromolecular model building and refinement into electron cryo-microscopy reconstructions By Alan Brown, Fei Long, Robert A Nicholls, Jaan Toots, Paul Emsley, Garib Murshudov Published in: Acta Crystallographica Section D: Biological Crystallography DOI: 10.1107/S1399004714021683 ABSTRACT A description is given of new tools to facilitate model building and refinement into electron cryo-microscopy reconstructions. Keywords: model building, refinement, electron cryo-microscopy reconstructions, LIBG INTRODUCTION Single-particle electron cryo-microscopy (cryo-EM) is currently undergoing a technical revolution (Kühlbrandt, 2014 ▶; Smith & Rubinstein, 2014 ▶). This has allowed the structures of macromolecules to be solved at near-atomic resolution (defined in this context as when the density map is sufficiently resolved to build a reasonably reliable full-atom model; Liao et al., 2013 ▶; Allegretti et al., 2014 ▶; Amunts et al., 2014 ▶). The improvement in resolution is predominantly owing to cameras that detect electrons directly and also feature improved quantum efficiencies and readout rates (Faruqi & McMullan, 2011 ▶). The new detectors have ignited developments in EM data processing, including software based on statistical algorithms that classify samples (Scheres, 2012 ▶) and correct for beam-induced sample motion (Li et al., 2013 ▶; Bai et al., 2013 ▶; Scheres, 2014 ▶). Structural information to near-atomic resolution is necessary to fully understand the detailed molecular mechanisms that underpin biological function. At resolutions of 4.5 Å or better the Cα backbone of protein components can be built based on the map alone, and at resolutions better than 4.0 Å amino-acid side chains become apparent. At these resolutions it should be possible to determine all-atom structures to the same degree of accuracy as with crystallographic data sets at similar resolutions. Indeed, since phases and amplitudes are determined equally well in EM, it is expected that models produced through the interpretation of EM density should be more accurate. The fit of the model to density and its consistency with expected chemical and structural knowledge are of equal importance. For this purpose, besides describing tools to facilitate model building, we also describe methods to refine the models using a suite of restraints derived from prior knowledge and to validate the results (Fig. 1 ▶). [Figure: Tools to facilitate the interpretation of EM data with atomic models.] LOCAL RESOLUTION HETEROGENEITY The overall resolution of a cryo-EM reconstruction is typically measured using the Fourier shell correlation (FSC), which provides a single value for the entire map and depends critically on the threshold criterion used (Rosenthal & Henderson, 2003 ▶; Scheres & Chen, 2012 ▶; Chen et al., 2013 ▶). The ‘gold-standard’ approach to resolution determination requires that during data processing the images are divided into two subsets (preferably at random), each containing one half of the images of the complete set. The FSC between the two maps at a threshold of 0.143 provides the resolution limit of the reconstruction (Rosenthal & Henderson, 2003 ▶). For a discussion of ‘gold-standard’ FSC calculations, please see Scheres & Chen (2012 ▶). However, cryo-EM maps are typically chimeras of regions of highly variable resolution, and a single resolution measurement can be misleading, although useful. Generating a three-dimensional reconstruction is the result of averaging many thousands of individual two-dimensional particle projections; each of these particles is unlikely to be in exactly the same conformation. Samples that have intrinsic flexibility or ligands that are present at less than full occupancy will display lower resolution than rigid regions at full occupancy. Inaccuracies in the alignment of individual particles will also limit resolution. To fully, and correctly, interpret the map it is important to know the resolution to which reliable features extend (Cardone et al., 2013 ▶). In X-ray crystallography, model-building and refinement strategies are selected on the basis of the overall resolution (Nicholls et al., 2012 ▶), but cryo-EM may require ‘multi-resolution modelling’ where separate strategies are employed in different regions of the same reconstruction. These strategies should not overlook data from complementary techniques (for example chemical cross-linking mass spectrometry) at lower resolution (Lasker et al., 2012 ▶). INTERPRETING EM DENSITY MAPS: FOLD RECOGNITION One strength of cryo-EM is the ability to determine structures of macromolecular complexes isolated from native sources in low yields. In such cases the individual components within the complex may not be known, as in a recent cryo-EM reconstruction of a ribosome-biogenesis intermediate (Leidig et al., 2014 ▶). Therefore, it is not possible to interpret the maps simply by docking high-resolution structures or comparative/ab initio models as this requires the identity of the components to be known; different strategies are required. At resolutions better than 4.0 Å it may be possible to trace the density and build the structure de novo; this model could then be used to interrogate the Protein Data Bank (PDB; Berman et al., 2002 ▶) for possible structural matches. If the resolution permits, it may be possible to deduce an amino-acid sequence from the side-chain densities that could be used to search protein-sequence databases. An alternative approach is fold recognition, where the density is searched for features resembling known protein domains and motifs. Two approaches have been described: FREDS (Khayat et al., 2010 ▶), which uses a protein-domain parser, PDP (Alexandrov & Shindyalov, 2003 ▶), to prepare a library of folds directly from the PDB that are then searched against the density map, and SPI-EM (Velázquez-Muriel et al., 2005 ▶), which determines the probability of a CATH-defined superfamily (of which there are currently 2500; Sillitoe et al., 2013 ▶) fitting the density rather than a brute search of a large library of domains. We have implemented density-based fold recognition using a curated database of protein domains, BALBES (Long et al., 2008 ▶), which is not restricted to categorized domains. BALBES was originally implemented as an automated molecular-replacement pipeline to use known structures to solve the crystallographic phase problem. While obtaining phases is not a problem in cryo-EM, the database can instead be utilized for screening against unidentified density. While any rigid-body docking program can be used with BALBES, we used MOLREP (Vagin & Teplyakov, 2010 ▶), which is suitable for accurate high-throughput fitting (Khayat et al., 2010 ▶). Alternative rigid-body docking software has recently been reviewed by Villa & Lasker (2014 ▶). At its core, the BALBES pipeline comprises a nonredundant database of approximately 50 000 protein domains greater than 15 amino acids in length and refined against data extending to resolution limits of better than 3.5 Å. Domains in the BALBES database are defined by their three-dimensional compactness and separability from other parts of a macromolecule. All these domains were selected and then trimmed from the existing nonredundant macromolecular subunits in the PDB, among which no two subunits had a sequence identity of greater than 80% and a root-mean-square deviation (r.m.s.d.) between corresponding Cα atoms of less than 1 Å. To further reduce the fold redundancy within these domains, we reclassified the domains according to identity of space groups, a similarity of unit-cell parameters of 95% and a sequence identity of 95%. The re-classification was carried out using a modified algorithm of equivalence classes (Press et al., 1992 ▶), full details of which will be published elsewhere. After re-classification, we have approximately 14 000 domains of likely unique folds. We also provide a new library, RNA Looplib, of structural RNA fragments