Read SHELXT - integrated space-group and crystal-structure determination. by Sheldrick GM. (2015) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc4283466.txt.

Introduction

George M Sheldrick describes SHELXT, a program that works out small molecule crystal structures with little human input. His paper appeared in Acta Crystallographica Section A in 2015. Solving a structure from X-ray data used to take expert steps in sequence; routine cases can now start from the raw reflection data alone.

Given the crystal data, its symmetry class, and a guess at which elements are present, SHELXT finds the space group, solves the structure, and assigns the elements. It blends older Patterson methods with direct methods and repeated recycling of partial solutions. The paper documents a tool that has become a standard first step in small molecule crystallography labs.

Catalog record

CREATORSheldrick GM.
YEAR2015
COLLECTIONPAPERS
FORMATTXT
FILE SIZE25 KB
LICENSECC BY 4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/articles/PMC4283466

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

SHELXT – Integrated space-group and crystal-structure determination By George M Sheldrick Published in: Acta Crystallographica. Section A, Foundations and Advances DOI: 10.1107/S2053273314026370 ABSTRACT SHELXT automates routine small-molecule structure determination starting from single-crystal reflection data, the Laue group and a reasonable guess as to which elements might be present. Keywords: Patterson superposition, direct methods, dual-space recycling, space-group determination, element assignment INTRODUCTION Although crystal structure determination by means of X-ray diffraction has had a major scientific impact for the last 100 years, it still requires the solution of the crystallographic phase problem. This problem arises because although methods for measuring the intensities of the diffracted X-rays have made considerable progress during that time, the direct experimental measurement of their relative phases is still only rarely practicable. Small-molecule crystal structures are usually solved by the use of probability relationships involving the phases of the stronger reflections, the so-called direct methods (Sheldrick et al., 2001 ▶; Giacovazzo, 2014 ▶) or more recently by the iterative use of Fourier transforms, e.g. dual-space methods such as charge flipping (Oszlányi & Sütő, 2004 ▶; Palatinus, 2013 ▶), in which the phases are constrained by the observed reflection intensities in reciprocal space and by the properties of the electron density in real space. Before the phase problem can be solved, the usual procedure is to determine the space group of the crystal with the help of the Laue symmetry of the diffraction pattern, the presence or absence of certain reflections (the systematic absences) and statistical tests (e.g. to distinguish between centrosymmetric and non-centrosymmetric structures). This space-group determination may be upset by the presence of dominant heavy atoms or by pseudo-symmetry affecting the intensities of certain classes of reflections, and in some cases the space group is ambiguous. For example, the space groups I222 and I212121 have the same systematic absences, as do Pmmn and two different orientations of Pmn21. Many dual-space methods perform at least as well when the data are first expanded to the nominal space group P1 (Sheldrick & Gould, 1995 ▶). In this paper ‘P1’ will be used to cover the centred triclinic non-centrosymmetric space-group settings such as C1 as well; the data do not need to be re-indexed for the primitive cell. After solving the phase problem in P1, the space group can be determined using the P1 phases (Burla et al., 2000 ▶; Palatinus & van der Lee, 2008 ▶) and this turns out to be a very robust general approach. SHELXT also employs this strategy. The systematic absences are not then used for the space-group determination, but all the weak reflections are still useful for identifying the best solution. Fig. 1 ▶ summarizes the course of structure determination using SHELXT. The individual stages will now be discussed in detail. The current version of SHELXT is intended for single-crystal X-ray data and is not suitable for neutron diffraction data. [Figure: Summary of the SHELXT procedure. The dual-space structure solution in P1, the space-group assignment and the isotropic refinement are performed in parallel. FFT = Fast Fourier transform. The modified observed and calculated structure factors G o and G c are discussed in the text and is the phase of G c.] SOLVING THE PHASE PROBLEM FOR DATA EXPANDED TO SPACE GROUP P1 SHELXT reads standard SHELX format and files. It extracts the unit cell, Laue group (but not space group) and the elements that are expected to be present (but not how many atoms of each). A number of options, e.g. that all trigonal and hexagonal Laue groups should be considered (), may be specified by command-line switches. A summary of the possible options is output when no filename is given on the SHELXT command line and further details are available on the SHELX home page. The data are first merged according to the specified Laue group and then expanded to P1. In theory, SHELXT could also have been programmed to determine the Laue group, e.g. by calculating the R values or correlation coefficients when the equivalent reflections are merged. However, the Laue group has to be known to scale the data, which is an essential step for the highly focused beams now common for synchrotrons and laboratory microsources, because the effective volume of the crystal irradiated is different for different reflections and needs to be corrected for. So in practice it is best to determine the Laue group first anyway. Even though programs such as XPREP (Bruker AXS, Madison, WI 53711, USA) are no longer required to determine the space group, it is still necessary to identify the correct unit cell and metric symmetry. Dual-space iteration starting from a Patterson superposition 2.1. The P1 dual-space recycling in SHELXT may start with random phases, but the default option of starting from a Patterson superposition minimum function (Buerger, 1959 ▶; Sheldrick, 1997 ▶) is usually more effective. Two copies of the sharpened Patterson function, displaced from each other by a strong Patterson vector, are superimposed and the minimum value of the two is calculated at each grid point. The resulting map is used as the initial electron density for the dual-space recycling. In an ideal case it is a double image of the structure consisting of 2N peaks, where N is the number of unique atoms, but the space-group symmetry has been lost. Since the dual-space recycling is being performed in P1 anyway, this is a good start and 2N is a significant reduction from the N 2 peaks in the original Patterson. The subsequent dual-space recycling is performed using the modified structure factors where E is the normalized structure factor, and a new density map is calculated by a hybrid difference Fourier synthesis with phases and coefficients where and G c are obtained by Fourier transformation of the current map. The default values for m and q are 3 and 0.5, respectively, but may be changed by the user. Based on experience with other structure-solution programs, q should probably be larger for large equal-atom structures and smaller for structures involving heavy atoms (to reduce Fourier ripples), but in practice it is rarely necessary to change the default values. SHELXT adds unmeasured data above and below the resolution limit of the data in the file similar to the free lunch method described by Caliandro et al. (2005 ▶). This enables structures to be solved at an earlier stage in the data collection and is particularly useful for data collected with diamond-anvil high-pressure cells, with which it is not always possible to collect complete data. It reduces the effects of series-termination errors in the Fourier syntheses, but tends to make the electron-density integration used to assign the element types less reliable. The random omit procedure 2.2. Omit maps are frequently used in macromolecular crystallography to reduce model bias. A small part of the structure is deleted and the rest is refined to reduce memory effects, then a new difference-density map is generated and interpreted. This concept plays an important role in SHELXT, but because no model is available at the P1 dual-space stage, it is implemented differently. The following density modification is performed unless otherwise specified by the user. A mask M(x) is constructed consisting of Gaussian-shaped peaks of unit volume at the positions of

Read the complete text