Transcranial alternating current stimulation (tACS).
Antal A, Paulus W. · 2013
Read Transcranial alternating current stimulation (tACS). by Antal A, Paulus W. (2013) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc3695369.txt.
Introduction
Antal and Paulus review transcranial alternating current stimulation, a method that passes a weak oscillating current through the skull to interact with the brain's own rhythms. Unlike steady stimulation, the alternating current can in principle pull cortical oscillations into step with its frequency, or disrupt them, and long sessions may leave lasting plastic changes.
Early results suggest frequency matters: theta-range stimulation may aid thinking when timed in phase, alpha may help movement, beta intrusion may hinder it, and gamma may affect attention. Some frequencies light up the retina or alter motor cortex excitability. The authors present tACS as a young technique with specific, testable promises rather than settled therapy.
Catalog record
| CREATOR | Antal A, Paulus W. |
|---|---|
| YEAR | 2013 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 25 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Transcranial alternating current stimulation (tACS) By Andrea Antal, Walter Paulus Published in: Frontiers in Human Neuroscience DOI: 10.3389/fnhum.2013.00317 ABSTRACT Transcranial alternating current stimulation (tACS) seems likely to open a new era of the field of noninvasive electrical stimulation of the human brain by directly interfering with cortical rhythms. It is expected to synchronize (by one single resonance frequency) or desynchronize (e.g., by the application of several frequencies) cortical oscillations. If applied long enough it may cause neuroplastic effects. In the theta range it may improve cognition when applied in phase. Alpha rhythms could improve motor performance, whereas beta intrusion may deteriorate them. TACS with both alpha and beta frequencies has a high likelihood to induce retinal phosphenes. Gamma intrusion can possibly interfere with attention. Stimulation in the “ripple” range induces intensity dependent inhibition or excitation in the motor cortex (M1) most likely by entrainment of neuronal networks, whereas stimulation in the low kHz range induces excitation by neuronal membrane interference. TACS in the 200 kHz range may have a potential in oncology. INTRODUCTION Transcranial alternating current stimulation (tACS)—the external application of oscillating electrical currents—is able to influence cortical excitability and activity (Antal et al., 2008; Chaieb et al., 2011; Moliadze et al., 2012; Wach et al., 2013). With exceptions (Marshall et al., 2006; Neuling et al., 2012) tACS is applied in most studies without a DC offset. It's simple form uses sinusoidal stimulation; however, any other waveform appears possible, such as rectangular current shapes. Ten Hz tACS was modeled in a realistic head model and was suggested to generate larger and more focused fields than DC stimulation (Manoli et al., 2012); with applied frequencies of 100 up to 1000 Hz a decrease of the size of this electrical field was assumed. This claim was, however, only based on differences in skin resistance at low frequencies which renders the statement quite doubtful (Paulus and Opitz, 2013). The major parameters that can shape the direction and the duration of the tACS-induced effects are the frequency, the intensity and the phase of the stimulation. The effect of duration of tACS on motor evoked potential (MEP) has not been systematically investigated yet. Increasing the duration of transcranial direct current stimulation (tDCS) results in a prolongation of the induced aftereffects (Nitsche and Paulus, 2000) up to about 13 min whereas doubling the 13 stimulation to 26 min inverses MEP aftereffects into inhibition (Batsikadze et al., 2013) It is unclear if this can be translated to tACS, too. ACS EFFECTS IN THE NORMAL BRAIN Frequency of the stimulation tACS may be applied in a wide frequency range. At present data are available between close to DC up to 5 kHz for plasticity studies (Chaieb et al., 2011) and 200 kHz for tumor therapy (Kirson et al., 2007) using a single frequency. However, any combination of frequencies is possible: one special form of tACS is transcranial random noise stimulation (tRNS), which so far has been studied with a frequency spectrum between 0.1 Hz and 640 Hz with a “white noise” characteristic (Terney et al., 2008). tACS applied at conventional EEG frequencies (0.1–80 Hz) and in the so called “ripple” range (140 Hz, see below) (Moliadze et al., 2010) may be able to interact with ongoing rhythms in the cortex. A very low frequency (0.75 Hz) stimulation combined with DC offset during non-rapid-eye-movement sleep in healthy humans enhances the retention of hippocampus-dependent declarative memories when tested the next morning (Marshall et al., 2006). The DC offset used in this study leaves open the possibility of a DC effect (Bergmann et al., 2009). Effects of tACS applied in the EEG range might differ depending on the outread parameters. A trend toward MEP inhibition following 10 Hz AC stimulation over the primary motor cortex (M1) was observed (Antal et al., 2008), while 10 Hz stimulation improved visuomotor implicit learning, using a serial reaction time task. In the MEP measurement shorter stimulation duration (5 min) was applied whereas tACS in the implicit learning study lasted about twice as long. Nevertheless, a dissociation between MEP excitability changes and implicit learning under tACS has already been described (Moliadze et al., 2010). 140 Hz stimulation induces the largest MEP increase, whereas only 250 Hz improved implicit motor learning. In another study, whereas 20 Hz tACS over the M1 increased corticospinal excitability (Feurra et al., 2011) as measured by MEP size, it slowed down voluntary movements using a visuomotor task (Pogosyan et al., 2009) but in parallel it increased beta coherence between scalp-recorded activity and electromyographic activity (EMG) of the first dorsal interosseus muscle. Opposing effects at beta and gamma frequencies depending on phase of a of motor task exist (Joundi et al., 2012): using a visually driven go—no-go task stimulation at 20 Hz afforded a significant but modest slowing of force production in the go task, however, stimulation in no-go trials, where the triggered motor task involved inhibition, led to a major reduction in force generation. In contrast, 70 Hz tACS was ineffective during errors of commission following no-go cues, but increased performance during go trials. TACS up to 80 Hz elicits phosphenes in a frequency- and intensity dependent way (Turi et al., 2013). When applied over the occipital cortex, the perception of phosphenes was peaking at about 15 Hz in brightness with a lower peak in darkness (Kanai et al., 2008). Although electrodes were placed over Oz and Cz, this effect was probably induced by far field stimulation at the retina (Schutter and Hortensius, 2010). TACS can probably only influence visual cortical functions at a subthreshold level as shown by modification of transcranial magnetic stimulation (TMS)-induced phosphene-thresholds (Kanai et al., 2010). Furthermore, contrast-discrimination thresholds were decreased only during 60 Hz tACS, but not during 40 and 80 Hz stimulations (Laczo et al., 2012). TACS applied over the PO9 and PO10 EEG electrode positions at the individual alpha frequency range (8–12 Hz) induced an entrainment of the applied oscillatory activity (Zaehle et al., 2010). However, it was recently documented that the after-effects of tACS applied at the individual alpha frequency may depend on the individual endogenous power: tACS was effective only under conditions of low endogenous alpha frequency power (Neuling et al., 2013). Furthermore, when stimulation frequency was fixed at 6 and 10 Hz, tACS impaired performance in the visual detection task (Brignani et al., 2013). tACS applied outside the conventional EEG frequency range, e.g., with frequencies of 140 Hz and in the low kHz range (1–5 kHz) increases excitability in a similar way than anodal tDCS, when 1 mA intensity is used (Moliadze et al., 2010; Chaieb et al., 2011). Stimulation at 80 Hz remains without an effect, while 250 Hz clearly had a delayed onset and shorter lasting response, compared to the MEP increase observed during and after 140 Hz tACS. The tRNS paradigm was developed with a potential to desynchronize normal and pathological cortical rhythms (Terney et al., 2008). The rationale behind this method is a possible entrainment with cortical oscillations of different frequencies at the same time. This may apply for intra-areal with higher oscillation frequencies or for inter-areal oscillations with lower frequencies. Input noise plays a role in sensitizing neuronal systems through a mechanism known as stochastic resonance (Wiesenfeld