Impedance-based cell monitoring: barrier properties and beyond.

Benson K, Cramer S, Galla HJ. · 2013

Read Impedance-based cell monitoring: barrier properties and beyond. by Benson K, Cramer S, Galla HJ. (2013) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc3560213.txt.

Introduction

Kathrin Benson, Sandra Cramer, and Hans-Joachim Galla reviewed electrical methods for watching cell barriers in Fluids and Barriers of the CNS in 2013. Sheets of epithelial and endothelial cells guard the borders between body compartments, with tight junctions sealing the gaps between cells. Lab models of these barriers need a way to check barrier strength without disturbing the cells or halting the experiment.

Measuring electrical resistance across the cell layer fills that need, and impedance methods extend it further. The review moves from simple resistance meters with two electrode sets to systems that track how resistance changes across frequencies and time. Such readings can flag leaks, follow deliberate opening of a barrier, and watch transport as it happens. Labs studying the blood-brain barrier and gut wall get a practical survey of what each setup can show.

Catalog record

CREATORBenson K, Cramer S, Galla HJ.
YEAR2013
COLLECTIONPAPERS
FORMATTXT
FILE SIZE40 KB
LICENSECC BY 4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/articles/PMC3560213

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Impedance-based cell monitoring: barrier properties and beyond By Kathrin Benson, Sandra Cramer, Hans-Joachim Galla Published in: Fluids and Barriers of the CNS DOI: 10.1186/2045-8118-10-5 ABSTRACT Abstract In multicellular organisms epithelial and endothelial cells form selective permeable interfaces between tissue compartments of different chemical compositions. Tight junctions which connect adjacent cells, control the passage of molecules across the barrier and, in addition, facilitate active transport processes. The cellular barriers are not static but can be deliberately modulated by exposure to specific external stimuli. In vitro models representing the essential absorption barriers of the body are nowadays available, thus allowing investigation of the parameters that control permeability as well as transport processes across those barriers. Independent of the origin of the barrier forming cells, techniques are needed to quantify their barrier integrity. One simple assay is to measure the permeability for given hydrophilic substrates possessing different molecular weights like sucrose or dextrans. However, this technique is time-consuming and labor-intensive. Moreover, radioactive or fluorescently-labeled substrates are needed to allow easy analytical detection. Finally, if transport processes are investigated, the standard permeant may interfere with the transport process under investigation or might even alter the barrier integrity by itself. Thus, independent, non-invasive techniques are needed to quantify the barrier integrity continuously during the experiment. Such techniques are available and are mainly based on the measurement of the transendothelial or transepithelial electrical resistance (TEER) of barrier forming cells grown on porous membranes. Simple devices using two sets of electrodes (so-called Voltohmeters) are widely used. In addition, an easy-to-use physical technique called impedance spectroscopy allows the continuous analysis of both the TEER and the electrical capacitance giving additional information about the barrier properties of cells grown on permeable membranes. This technique is useful as a quality control for barrier forming cells. Another impedance-based approach requires cells to be grown directly on solid, micro-structured electrodes. Here, we will discuss the physical background of the different techniques; advantages, disadvantages, and applications will be scrutinized. The aim is to give the reader a comprehensive understanding concerning the range and limits of the application, mainly focusing on endothelial cells. Keywords: Barrier forming cells, Endothelium, Epithelium, Blood–brain barrier, Electrical resistance, TEER, Impedance spectroscopy REVIEW Barrier-forming cells A characteristic feature of epithelial as well as endothelial cell layers is the formation of intercellular junctions resulting in a tight cellular barrier separating the apical (luminal) from the basolateral (abluminal) side. These cell layers form selectively permeable interfaces between compartments of different chemical composition, thus controlling diffusion along the paracellular way as well as transport processes through intracellular pathways. This is guaranteed by the so-called tight junctions (intercellular connections) that seal the intercellular cleft [1]. An intact barrier is crucial for the physiological activities of the corresponding tissue. However, the barrier is not static but can be modulated by specific stimuli to open and close selectively, thus allowing controlled passage from the blood to the brain or vice versa[2-4]. Developing methods to overcome the barrier is an important issue and highly relevant for medical treatment of diseases within the barriers. Drug delivery systems or strategies to open the barrier temporarily will help to allow medication to cross the blood–brain and the blood-CSF (cerebrospinal fluid) barrier as well as other barriers such as in the intestine, the kidney, the testis and the placenta. Adequate in vitro models are nowadays available, based on cell cultures grown on permeable supports [5]. These are of major importance since the setup offers full access to both the apical and the basolateral compartments. In vitro models can, in principle, be based on primary cells [6,7] or cell lines [8,9]. However, in case of blood–brain barrier (BBB) models most cell lines do not express barrier properties similar to in vivo conditions [10]. Thus care has to be taken if such cells are used for transport experiments. Since the presence of an intact barrier is crucial for reliable in vitro experiments, techniques had to be developed to quantify the barrier integrity. One possibility is to measure the permeability for small hydrophilic substances like radioactively labeled sucrose or low molecular weight fluorescent dyes [11]. A straightforward method is the measurement of the TEER. A scrutiny of different TEER measurements will be given here. The major focus will be on techniques that allow automated long-term monitoring of barrier-relevant parameters including the dynamic processes within the tight junction network. TEER measurement according to Ohm`s law A quantitative measure describing the barrier integrity is the electrical, ohmic resistance of the cell layer. In principle it can be determined by a simple, direct current (DC) based approach: a defined DC voltage, U, is applied to two electrodes, one on each side of the cell layer. The resulting current, I, is measured leading to the ohmic resistance R according to Ohm`s law (R = U/I). However the DC current can easily cause adverse effects on both the cells and the electrodes. The latter point has been avoided in case of the widely-used, so-called Epithelial Voltohmmeter (EVOM) [12]. Here an alternating current (AC) square wave with a frequency of 12.5 Hz is used to avoid charging of the cell layer and the electrodes (Figure 1). However, as a handheld device with a chopstick-like arrangement of the electrodes, the resulting TEER readings depend strongly on the position of the probing electrodes. The required movement of the electrodes from one well to the other easily causes disturbances and is attended by a disruption of the physiological conditions as the cell cultures have to be temporarily removed from the incubator. Furthermore, the inherent inhomogeneity of the electric field across the cell layer typically leads to a systematic overestimation of TEER [13]. Altogether, there is a significant risk of obtaining erroneous results with this technical approach. [Figure: Impedance measurements with chopstick-like electrodes. The chopstick-like electrodes (E1,E2) are traditionally used to determine the electric resistance of cells grown on filter inserts. The ohmic resistance of the cell layer (TEER), the cell culture medium in the upper and lower compartment (RMed), the membrane of the filter inserts (Rpm) and electrode-medium interface (RE) all contribute to the total electric resistance. IAC: alternating current. Adapted from [14] with permission.] Automated impedance-based cell monitoring under physiological conditions using the cellZscope® device Basics of the technique Impedance spectroscopy is a highly reliable technique to measure the transendothelial or transepithelial electrical resistance (TEER). In impedance spectroscopy the frequency of an applied AC voltage is swept while measuring the amplitude and the phase of the resulting AC current. The resulting total impedance, Z, contains information not only about the TEER, but also the capacitance of the cell layer can be extracted and provided as a readout parameter. This non-invasive method can be applied to living cells without markers and allows them to be monitored during growth and differentiation [14]. Additionally, the barrier properties can be characterized before using the cultures in subsequent experiments. To examine the TEER of cells grown on the porous membrane of standard cell culture inserts, a computer-controlled multi-well device that automatically derives all important parameters has been developed (cellZscope, nanoAnalytics GmbH, Muenster, Germany, Figure 2). [Figure: Setup of the cellZscope device. The cell module can be loaded with a broad range of standard cell culture inserts ranging

Read the complete text