Assessment of tumor heterogeneity: an emerging imaging tool for clinical practice?
Davnall F, Yip CS, Ljungqvist G, Selmi M, Ng F, Sanghera B, Ganeshan B, Miles KA, Cook GJ, Goh V. · 2012
Read Assessment of tumor heterogeneity: an emerging imaging tool for clinical practice? by Davnall F, Yip CS, Ljungqvist G, Selmi M, Ng F, Sanghera B, Ganeshan B, Miles KA, Cook GJ, Goh V. (2012) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc3505569.txt.
Introduction
Tumors are patchy inside, and Fergus Davnall and nine colleagues review whether image texture can measure that patchiness for clinical use in 2012. Texture analysis computes patterns in scans that the eye cannot judge reliably, using statistical, model-based, and transform-based methods across CT, MRI, and PET imaging.
Uneven tumor structure predicts worse outcomes, so a number for it has value. Early evidence suggests texture can sharpen diagnosis, staging, and judging whether treatment is working. Small studies and a lack of standards have so far kept it out of routine practice. The review maps those technical hurdles and argues the method could become a valuable everyday tool in cancer imaging.
Catalog record
| CREATOR | Davnall F, Yip CS, Ljungqvist G, Selmi M, Ng F, Sanghera B, Ganeshan B, Miles KA, Cook GJ, Goh V. |
|---|---|
| YEAR | 2012 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 50 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Assessment of tumor heterogeneity: an emerging imaging tool for clinical practice? By Fergus Davnall, Connie S. P. Yip, Gunnar Ljungqvist, Mariyah Selmi, Francesca Ng, Bal Sanghera, Balaji Ganeshan, Kenneth A. Miles, Gary J. Cook, Vicky Goh Published in: Insights into Imaging DOI: 10.1007/s13244-012-0196-6 ABSTRACT Background Tumor spatial heterogeneity is an important prognostic factor, which may be reflected in medical images Methods Image texture analysis is an approach of quantifying heterogeneity that may not be appreciated by the naked eye. Different methods can be applied including statistical-, model-, and transform-based methods. Results Early evidence suggests that texture analysis has the potential to augment diagnosis and characterization as well as improve tumor staging and therapy response assessment in oncological practice. Conclusion This review provides an overview of the application of texture analysis with different imaging modalities, CT, MRI, and PET, to date and describes the technical challenges that have limited its widespread clinical implementation so far. With further efforts to refine its application, image texture analysis has the potential to develop into a valuable clinical tool for oncologic imaging. Teaching Points • Tumor spatial heterogeneity is an important prognostic factor. • Image texture analysis is an approach of quantifying heterogeneity. • Different methods can be applied, including statistical-, model-, and transform-based methods. • Texture analysis could improve the diagnosis, tumor staging, and therapy response assessment. INTRODUCTION Tumor heterogeneity Imaging is used widely in oncologic practice for lesion characterization, confirmation of diagnosis, staging, treatment planning, targeting therapy, assessing treatment response, and surveillance. Diagnosis and staging are typically based on a lesion’s anatomical appearance and the extent of tumor spread on imaging. Different imaging modalities, such as X-ray, ultrasound (US), computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET), can be used singly or in combination, depending on the tumor type, site, and clinical question to be answered. A limitation that applies to all imaging modalities is that image intepretation is based on a visual process. Yet, there are features within each image that may not be appreciated readily by the naked eye. Furthermore, when images are analyzed in a more quantitative manner, standard region of interest analysis may provide a mean parameter value, e.g., Hounsfield unit (HU) on CT, signal intensity (SI) on MRI, or standardized uptake value (SUV) on PET, but does not typically describe the underlying spatial distribution. Tumors are heterogeneous both on genetic and histopathological levels (Fig. 1) with intratumoral spatial variation in the cellularity, angiogenesis, extravascular extracellular matrix, and areas of necrosis. Tumors with high intratumoral heterogeneity have been shown to have poorer prognosis, which could be secondary to intrinsic aggressive biology or treatment resistance [1–3]. It is difficult to assess intratumoral heterogeneity with random sampling or biopsy as this does not represent the full extent of phenotypic or genetic variation within a tumor. Thus, a non-invasive method of assessing the heterogeneity within a tumor might be of clinical benefit, particularly in this age of personalized medicine, to select poor prognosis patients for more intensive therapy. Hence, tumor heterogeneity is a clinically relevant parameter for imaging that may be quantifiable and that could augment standard reporting methods. Fig. 1Non-small-cell lung cancer showing spatial variation in staining for angiogenesis (CD34), pimonidazole (hypoxia), and glucose transporter protein expression (Glut-1) Texture analysis Texture analysis refers to a variety of mathematical methods that can be used to evaluate the gray-level intensity and position of the pixels within an image to derive so-called ‘texture features’ that provide a measure of intralesional heterogeneity [4]. Different methods have been applied, including statistical-, model-, and transform-based methods [5–12]. Statistical-based techniques have been most commonly applied and describe the distribution and relationships of gray-level values in the image. Three orders of parameters are described in statistical-based texture analysis. First-order statistics relate to gray-level frequency distribution within the region of interest, which can be obtained from the histogram of pixel intensities [13]. It is dependent on a single pixel value rather than its interaction with neighboring pixels. First-order statistics, based on histogram analysis, include mean intensity, maximum intensity, minimum intensity, uniformity (uniformity of gray-level distribution), entropy (irregularity of gray-level distribution), standard deviation of the gray-level histogram distribution, skewness (asymmetry of the histogram), and kurtosis (flatness of the histogram) (Appendix). Second-order statistics are co-occurrence measurements calculated using spatial gray-level dependence matrices. These matrices determine how often a pixel of intensity i finds itself within a certain relationship to another pixel of intensity j. Second-order statistics based on a co-occurrence matrix (GLCM) include entropy (randomness of the matrix), energy/angular second moment (pixel repetition/orderliness and measures the homogeneity of an image), homogeneity (uniformity of co-occurrence matrix), dissimilarity (measurement of how different each element in the matrix is), and correlation (measurement of gray-tone linear dependencies). Another method to derive second-order statistics is the run-length matrix (RLM), which analyzes texture in a specific direction. A run is a length of consecutive pixels with the same gray-level intensity in a preset direction. The relationships between the run lengths give rise to texture. Fine texture has more short runs with similar gray-level intensities, whereas coarse texture has more long runs with different gray-level intensities. Some of the RLM parameters include short-run emphasis (SRE; measures distribution of short runs in an image), long-run emphasis (LRE), gray-level non-uniformity (GLNU; measures similarity of gray-level values; GLNU is small if variation is less), and run length non-uniformity (RLNU; measures the similarity of run lengths; RLN is small if run lengths are similar). Higher-order statistics are calculated using neighborhood gray-tone-difference matrices, which examine the spatial relationship among three or more pixels and are thought to closely resemble the human experience of the image [14, 15]. This is calculated using the neighborhood gray-tone-difference matrix (NGTDM). Examples of higher-order statistics include contrast (number of local variations within the image), coarseness (measurement of edge density), and busyness (measurement of spatial rate of gray-level change). The application of filters such as Laplacian of Gaussian bandpass filters in statistical-based texture analysis of an image allows the extraction of specific structures corresponding to the width of the filters. Lower filter values (filter 0.5-1.0) will highlight structures with fine textures, and higher filter values highlight structures with medium (filter 1.5-2.0) and coarse (filter 2.5) textures in the filtered image. Model-based approaches represent texture using sophisticated mathematical models such as fractal analysis. Fractal analysis is a form of pattern or geometric recognition. The fractal dimension is a measurement of the irregularity or roughness of a surface [13, 15]. Hence, the greater the fractal dimension is, the rougher the texture. Transform-based methods, such as Fourier, Gabor, and wavelet transforms, analyze texture in a frequency or the scale space. Fourier transform analyzes the frequency content without spatial localization and hence is not often used. Gabor transform is essentially a windowed-Fourier transform derived by the introduction of Gaussian function, which then allows for frequency and spatial localization but is limited by its single filter resolution. This problem is overcome by wavelet transform, which uses multiple channels tuned to different frequencies [15] (Appendix). Texture analysis is not a new technique and has been studied for medical imaging since 1973, when applied to radiographs, and subsequently to ultrasound [16–18]. More recently, texture analysis has been applied to CT (Figs. 2, 3)