Read Multiple applications of Alamar Blue as an indicator of metabolic function and cellular health in cell viability bioassays. by Rampersad SN. (2012) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc3478843.txt.
Introduction
Rampersad reviewed the many uses of Alamar Blue, a dye that shows whether cells are alive and active, in Sensors in 2012. Living cells change the dye's chemistry, so its signal tracks cell health. Labs had used it for fifty years across bacteria, yeast, fungi, and animal cells, for tasks from drug screening to testing water safety.
The review weighs the dye's strengths against rival tests and flags the traps in its use. Results can shift with cell type, dose, and timing, so each new setup needs its own checks. Rampersad gives design advice and a checklist for judging whether the assay fits a planned study. Used with care, the dye offers a cheap, gentle way to follow cell health over time.
Catalog record
| CREATOR | Rampersad SN. |
|---|---|
| YEAR | 2012 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 44 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Multiple Applications of Alamar Blue as an Indicator of Metabolic Function and Cellular Health in Cell Viability Bioassays By Sephra N Rampersad Published in: Sensors (Basel, Switzerland) DOI: 10.3390/s120912347 ABSTRACT Abstract Accurate prediction of the adverse effects of test compounds on living systems, detection of toxic thresholds, and expansion of experimental data sets to include multiple toxicity end-point analysis are required for any robust screening regime. Alamar Blue is an important redox indicator that is used to evaluate metabolic function and cellular health. The Alamar Blue bioassay has been utilized over the past 50 years to assess cell viability and cytotoxicity in a range of biological and environmental systems and in a number of cell types including bacteria, yeast, fungi, protozoa and cultured mammalian and piscine cells. It offers several advantages over other metabolic indicators and other cytotoxicity assays. However, as with any bioassay, suitability must be determined for each application and cell model. This review seeks to highlight many of the important considerations involved in assay use and design in addition to the potential pitfalls. Keywords: Alamar Blue, cell viability, cytotoxicity, resazurin INTRODUCTION Alamar Blue has been widely used over the past 50 years in studies on cell viability and cytotoxicity in a range of biological and environmental systems. It is one of the most highly referenced substances used for cytotoxicity and viability assays; PubMed records list over 200 publications citing Alamar Blue (resazurin) and cancer research and over 1,000 publications in drug screening, development and discovery. Generally, its use has been applied to various aspects of monitoring cellular health [1,2], apoptosis, cell cycle function and control [3–8], test compound toxicology in medicine and in environmental risk assessments [9–13], cytotoxicity [14–16] and antimicrobial susceptibility testing [17,18]. It has also been used to assess various bacteria, yeast and fungal species and different cell types including, but not limited to fibroblasts [19], immortalized and cancer cell lines [9,20,21], mouse and human lymphocytes [1,22], primary neuronal cell culture [4], and various animal cell lines [23,24]. As with any viability assay, optimization and assessment of compatibility must be carried out for every cell model. The objective of this review is to highlight the more important considerations involved in assay use, design and the potential pitfalls. This review gives an introduction and discussion of cell assays including their formats, chemistries, advantages and limitations, followed by a discussion of the Alamar Blue assay which covers basic chemistry, optimization parameters for the user, specific studies in relation to Alamar Blue assay optimization and comparison with other bioassays, concluding statements and a checklist of important points to consider with respect to suitability of the assay to a any given study. CELL VIABILITY AND CELL PROLIFERATION ASSAYS Cell Viability Assays 2.1. Morphological methods (including ultrastructural studies) require highly skilled personnel, expensive equipment and results are not usually quantifiable; cells must also be destroyed so continuous monitoring or kinetic studies are ruled out. Various cell viability and cell proliferation assays are used to determine the effect of a test compound on cells propagated in vitro. Indirect techniques that assess cell viability by monitoring cell membrane integrity after drug exposure, i.e., dye exclusion and preferential dye uptake, also destroy or interfere with the cell's functioning and hence are terminal assays. Other assays that measure cell viability, indirectly, by quantitation of reduction of the intracellular environment using indicator metabolic markers are useful and offer fewer limitations than other methods. Assays that quantify intracellular ATP (the ATP status of cells reflects the cells' energy capacity and viability) have also been developed where the concentration of ATP in indicative of the number of viable cells in that culture. Other biomarkers that can be quantified include NADH, capases, LDH, in addition to live- and dead-cell proteases (www.promega.com). One potential drawback of some of these metabolic assays is there is no differentiation between cells that are actively dividing and those that are quiescent which may result in an over-estimation of cell number. Also, an increase in cell growth may indicate cell viability but, a decrease in viability can be interpreted as the result of either cytotoxic effects of a particular test compound or induction of sub-optimal assay conditions. Cell Proliferation Assays Using Nucleotide Analogs 2.2. Cell proliferation assays monitor actively dividing cells, expressed either as the actual number of active cells or the ratio of proliferating to non-proliferating cells in culture [25–27]. Quiescent cells that are healthy but not proliferating are not detected by cell proliferation assays. Measurement of DNA synthesis has been used as a specific marker in actively dividing cells. In these assays, labeled nucleotide analogs (e.g., [3H]-thymidine or 5-bromo-2′-deoxyuridine [BrdU]) are added to cells and are incorporated into the replicated DNA during the S phase of the cell cycle. The amount of labeled nucleotide is then quantified by: (i) measuring the total amount of labeled DNA in the cell population, or by (ii) counting the number of labeled nuclei under a microscope. The growth rate of the cells will determine the rate of cell turnover which dictates the incubation period with the labeled nucleotide analogs. Quantitation of DNA content of cells based on radioisotopic assays are terminal, labor-intensive and present handling, storage, and disposal issues. They are also time-consuming and subject to operator errors especially for medium to high-throughput applications [25]. The clonogenic assay measures the effect of a test compound on the proliferating fraction of the population (for a review of these assays see references [25–27]). A Comparison of Tetrazolium Salts as Metabolic Indicators 2.3. Tetrazolium salt reduction is a commonly used, cost-effective indirect measure of viable cell number. The most frequently used tetrazolium salts are 3-(4,5-dimethyethiazol-2-yl)-2, 5-diphenyltetrazolium bromide (MTT), sodium 3′- [1-phenylamino)-carbonyl]-3,4-tetrazolium]-bis (4-methoxy-6-nitrobenzene) sulfonic acid hydrate (XTT), and 4-[3-(4-iodophenyl)-2-(4-nitrophenyl)-2H-5-tetrazolio]-1,3-benzene disulfonate, water-soluble tetrazolium salt (WST-1). Despite their wide use and applicability, users of these assays may encounter a number of incompatibility problems depending on the study objectives. For example, compared to XTT and MTS, WST-1 is more stable, has a broader linear range and enables more rapid color development. MTT can be reduced by NADPH, FADH, FMNH, and NADH, but not by the cytochromes. Tetrazolium salts are generally cytotoxic because the formazan crystals that are produced from reduction of the salts must be solubilized with DMSO or HCl/isopropanol which destroys the cells under investigation so time-course experiments cannot be carried out [14]. MTT is not soluble in culture medium and is best suited for use with adherent cell lines; however, XTT is soluble in culture medium and is suitable for use with both non-adherent as well as adherent cell lines but XTT is not efficiently reduced without PMS (phenozine methosulfate) (www.assay.nih.gov/assay/). Thus, selection of the most appropriate tetrazolium salt as an indicator of metabolic activity is important. Alamar Blue circumvents many of the incompatibility issues described and offers many advantages over tetrazolium salts. Characteristics of a Robust Viability Assay 2.4. There is a range of commercially available assays which require careful optimization according to the manufacturer's recommendations (for example, www.ab-direct.com; www.promega.com; www.invitrogen.com; www.trekds.com). It is important that the user defines what the assay has to measure, the cell model under study, and whether end-point determinations are necessary. The correlation between measurement and cell viability (taken as the number of live cells)