A review of accelerometry-based wearable motion detectors for physical activity monitoring.
Yang CC, Hsu YL. · 2010
Read A review of accelerometry-based wearable motion detectors for physical activity monitoring. by Yang CC, Hsu YL. (2010) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc3231187.txt.
Introduction
Che-Chang Yang and Yeh-Liang Hsu reviewed wearable motion detectors built on accelerometers in this 2010 paper in Sensors. How a person moves reveals much about mobility, chronic disease, and aging, and small worn accelerometers offer a practical way to measure it. The authors survey how the technology developed and where it is used.
They explain how accelerometry works, the properties of the sensors, and where on the body they are placed. Studies they review classify posture and movement, estimate energy expenditure, detect falls, and evaluate balance. The paper then compares commercial products, giving a snapshot of the market at the time. It closes with an outlook on emerging technologies for activity monitoring.
Catalog record
| CREATOR | Yang CC, Hsu YL. |
|---|---|
| YEAR | 2010 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 52 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring By Che-Chang Yang, Yeh-Liang Hsu Published in: Sensors (Basel, Switzerland) DOI: 10.3390/s100807772 ABSTRACT Abstract Characteristics of physical activity are indicative of one’s mobility level, latent chronic diseases and aging process. Accelerometers have been widely accepted as useful and practical sensors for wearable devices to measure and assess physical activity. This paper reviews the development of wearable accelerometry-based motion detectors. The principle of accelerometry measurement, sensor properties and sensor placements are first introduced. Various research using accelerometry-based wearable motion detectors for physical activity monitoring and assessment, including posture and movement classification, estimation of energy expenditure, fall detection and balance control evaluation, are also reviewed. Finally this paper reviews and compares existing commercial products to provide a comprehensive outlook of current development status and possible emerging technologies. Keywords: accelerometry, accelerometer, physical activity, human motion, energy expenditure, gait, fall detection INTRODUCTION Physical activity (PA) is regarded as any bodily movement produced by skeletal muscles which results in an energy expenditure [1]. PA has been studied in epidemiological research for investigating human movements and the relationship to health status, especially in the area of cardiovascular diseases, diabetes mellitus and obesity. A declining PA level represents a major factor in multiple illnesses and symptoms related to functional impairment [2]. The organization Healthy People 2020 [http://www.healthypeople.gov/HP2020/] led by the U.S. government has recognized PA as one of the leading health indicators (LHI), which are a measurement of health of a nation’s population. Various methods of subjective and objective PA assessment tools have been developed. Subjective methods, such as diaries, questionnaires and surveys, are inexpensive tools. However, these methods often depend on individual observation and subjective interpretation, which make the assessment results inconsistent [3]. Some standard tests for PA assessment also require subjective judgments. For example, the timed up-and-go test (TUG-T) is a simple test for evaluating one’s ability to perform a sequence of basic activities, and the result of the TUG-T can be a predictor for risk of falling [4]. Distinguishing postural transitions in the TUG-T, however, depends on subjective judgment that counts the time taken for each posture transition. The Berg Balance Scale (BBS), a valid measure to evaluate balance control of the elderly individuals, also requires subjective observation and determination for scoring some test items [5]. On the other hand, objective techniques use wearable, or body-fixed motion sensors, which range from switches, pedometers, actometers, goniometers, accelerometers and gyroscopes, for PA assessment. Mechanical pedometers, or so-called “step counters”, are the simplest wearable sensors to measure human motion. The pedometer uses a spring-loaded mass or some other switch mechanism to detect the obvious impacts produced by steps during locomotion. The number of steps during motion can be registered to estimate the distance walked and the energy expenditure. Though pedometers are cheap and simple, the major drawbacks are that pedometers cannot reflect intensity of movement and therefore result in inaccurate energy expenditure estimations [6]. PA can also be objectively measured by means of magnetic systems, optical systems, or video recording. Magnetic and optical systems for PA monitoring are costly and require complex instrumentation and environment setting. Privacy concerns are a major drawback in monitoring systems based on video recording. These systems may not be practical for monitoring subjects in free-living environments. Accelerometers are sensors which measure the accelerations of objects in motion along reference axes. Measuring PA using accelerometry is preferred because acceleration is proportional to external force and hence can reflect intensity and frequency of human movement. Accelerometry data can be used to derive velocity and displacement information by integrating accelerometry data with respect to time [7]. Some accelerometers can respond to gravity to provide tilt sensing with respect to reference planes when accelerometers rotate with objects. The resulting inclination data can be used to classify body postures (orientations). With these characteristics, accelerometry is capable of providing sufficient information for measuring PA and a range of human activities. Accelerometers have been widely accepted as useful and practical sensors for wearable devices to measure and assess PA in either clinical/laboratory settings or free-living environments [8]. Accelerometers were first investigated in the 1950s to measure gait velocity and acceleration [9]. Accelerometry measurement of human motion was studied in more detail during the 1970s due to technological advances [10]. It was also shown that accelerometers had advantages over other techniques in quantitatively measuring human movement. Micro-electromechanical system (MEMS) technology has reduced the cost of accelerometers in smaller form factors. In the meantime, sensor performance has been enhanced while the power consumption is greatly reduced. The first batch-fabricated MEMS accelerometers were reported in 1979 [11]. Since then various research and commercial applications have used MEMS accelerometers in wearable systems for PA monitoring. This paper provides a comprehensive review on the working principles, capabilities, and various applications of accelerometry-based wearable motion detectors for PA monitoring and assessment. The authors searched for published literature after year 2000 using a range of related keywords such as “accelerometry”, “accelerometer”, “wearable”, “physical activity”, “human motion”, “human movement”, “activity classification”, “energy expenditure”, “fall detection”, “balance stability” and “gait”. Selected literatures before year 2000 are also included. This paper first discusses the principles and fundamentals of accelerometry, along with different sensor placements. Various research using accelerometry-based wearable motion detectors for PA monitoring and assessment, including posture and movement classification, estimation of energy expenditure, fall detection and balance control evaluation, are then reviewed. Finally this paper reviews and compares existing commercial products to provide a comprehensive outlook of current development status and possible emerging technologies. DESIGN FUNDAMENTALS FOR ACCELEROMETRY-BASED WEARABLE MOTION DETECTORS Accelerometry: Principles and Sensors 2.1. Inertial sensors are basically force sensors to sense linear acceleration along one or several directions, or angular motion about one or several axes. The former is referred to as an accelerometer, and the later a gyroscope. The common operation principle of accelerometers is based on a mechanical sensing element which consists of a proof mass (or seismic mass) attached to a mechanical suspension system with respect to a reference frame. Inertial force due to acceleration or gravity will cause the proof mass to deflect according to Newton’s Second Law. The acceleration can be measured electrically with the physical changes in displacement of the proof mass with respect to the reference frame. Piezoresistive, piezoelectric and differential capacitive accelerometers are the most common types [12,13]. Piezoresistive accelerometers 2.1.1. The sensing element consists of a cantilever beam and its proof mass is formed by bulk-micromachining. The motion of the proof mass due to acceleration can be detected by piezoresistors in the cantilever beam and proof mass. The piezoresistors are arranged as a Wheatstone bridge to produce a voltage proportional to the applied acceleration. Piezoresistive accelerometers are simple and low-cost. The piezoresistive accelerometers are DC-responsive that can measure constant acceleration such as gravity. The major drawbacks of piezoresistive sensing are the temperature-sensitive drift and the lower level of the output signals. Piezoelectric accelerometers 2.1.2. In a piezoelectric accelerometer, the sensing element bends due to applied acceleration which causes a displacement of the seismic mass, and results in an output voltage proportional to the applied acceleration. Piezoelectric accelerometers do not respond to the constant component of accelerations. Differential capacitive accelerometers 2.1.3. The displacement of the