Microfluidic mixing: a review.
Lee CY, Chang CL, Wang YN, Fu LM. · 2011
Read Microfluidic mixing: a review. by Lee CY, Chang CL, Wang YN, Fu LM. (2011) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc3116190.txt.
Introduction
Chia-Yen Lee and colleagues surveyed tiny devices for mixing fluids in a 2011 review in the International Journal of Molecular Sciences. Lab-on-a-chip tools handle drops far too small for stirring, so blending samples quickly and fully is a core design problem. At that scale, blending depends mostly on molecules spreading between streams on their own.
The review sorts designs into two families. Active designs shake or push the fluids with outside energy, such as sound, heat, or electric force. Passive designs instead stretch the contact between streams through winding or split channels, needing no extra power. After a decade of proposals, the authors compare the main designs so engineers can match a mixer to their device and task.
Catalog record
| CREATOR | Lee CY, Chang CL, Wang YN, Fu LM. |
|---|---|
| YEAR | 2011 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 53 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Microfluidic Mixing: A Review By Chia-Yen Lee, Chin-Lung Chang, Yao-Nan Wang, Lung-Ming Fu Published in: International Journal of Molecular Sciences DOI: 10.3390/ijms12053263 ABSTRACT Abstract The aim of microfluidic mixing is to achieve a thorough and rapid mixing of multiple samples in microscale devices. In such devices, sample mixing is essentially achieved by enhancing the diffusion effect between the different species flows. Broadly speaking, microfluidic mixing schemes can be categorized as either “active”, where an external energy force is applied to perturb the sample species, or “passive”, where the contact area and contact time of the species samples are increased through specially-designed microchannel configurations. Many mixers have been proposed to facilitate this task over the past 10 years. Accordingly, this paper commences by providing a high level overview of the field of microfluidic mixing devices before describing some of the more significant proposals for active and passive mixers. Keywords: active mixer, microfluidic mixing, passive micromixer INTRODUCTION Microfluidic devices have had a considerable impact on the fields of biomedical diagnostics and drug development, and are extensively applied in the food and chemical industries. The diminutive scale of the flow channels in microfluidic systems increases the surface to volume ratio, and is therefore advantageous for many applications. However, the specific Reynolds number (Re = 1 ρv/η) of liquid flows in such microchannels is very small. For example, the Reynolds number is of the order of 0.1 in a typical water-based microfluidic system with a channel width of 100 μm, a liquid flow rate of 1 mm/s, a fluid density of 1 g/cm3 and a viscosity of 0.001 Ns/m2. In such low Reynolds number regimes, turbulent mixing does not occur, and hence diffusive species mixing plays an important role but is an inherently slow process. Consequently, the aim of microfluidic mixing schemes is to enhance the mixing efficiency such that a thorough mixing performance can be achieved within shorter mixing channels, which can reduce the characteristic size of microfluidic devices. Furthermore, the development of efficient mixing schemes is essential for increasing the throughput of microfluidic systems and to realize the concept of micro-total-analysis systems and lab-on-a-chip systems. Increasing the contact area between the species to be mixed is one of the most efficient means of enhancing the diffusive mixing effect. Accordingly, previous studies presented mixing schemes by feeding the samples of interest through discrete via holes, cantilever plate-valves or multi-channels in the microfluidic device. An alternative approach is to increase the contact area between the mixing species by designing the microchannel configurations so that the species are folded multiple times as they flow along the mixing channel. In passive mixing devices such as those described above, samples can typically be mixed within 55–300 ms, and hence the requirement for high device throughputs can be readily achieved. Besides increasing the contact area, the mixing performance can also be improved by increasing the time of contact between the multiple species. However, such schemes typically result in a lower mixing efficiency, and thus require a longer mixing channel to achieve a satisfactory mixing result (Table 1). [Table: Performance of active micromixers in recent five years [1–11].] In contrast to the passive mixing schemes presented above in which the microchannel configuration is specifically designed to increase either the contact area or the contact time (or both) of the multiple species, active mixing schemes improve the mixing performance by applying external forces to the sample flows to accelerate the diffusion process [12]. Typically, active mixing schemes are implemented by incorporating some form of mechanical transducer within the microfluidic device using microfabrication techniques. For example, microfluidic mixers, which use embedded ultrasonic transducers to generate acoustic waves to stir the samples, have been shown to achieve a high mixing performance. However, acoustic vibrations also generate considerable heat that may lead to unwanted reactions between the samples. Various microfluidic devices with embedded microelectrodes for mixing the sample fluids dielectrophoretically have also been presented. The use of embedded electrode pairs has been shown to change the surface energy of the microchannel walls, providing an efficient means of enhancing species mixing by inducing local instabilities in the flow stream. The use of embedded electrode pairs has many of the advantages of active mixing schemes but does not require moving components, and hence results in cheaper and more reliable microfluidic devices (Table 2). [Table: Performance of passive micromixers in recent five years [13–25].] The microfluidic mixers presented above are all considered for the mixing of continuous bulk liquids. However, various discrete droplet-based mixing platforms have also been proposed. One such scheme involves the use of air pressure to form, actuate and mix two liquid droplets in a hydrophobic microcapillary valve device. Recently, many studies have presented mixing devices using liquid droplets based on electro-wetting phenomena. In these schemes, electro-wetting actuation is applied to separate liquid droplets from the bulk and to drive them to specific locations where they are repeatedly combined, mixed and separated. The microfluidic mixing of liquid droplets through the application of electro-wetting-induced droplet oscillations has also been demonstrated. These microfluidic mixing schemes take advantage of the open structure of the flow channel, allowing the mixed sample to be more easily transported to its required destination. ACTIVE MICROFLUIDIC MIXERS Active microfluidic mixers enhance the mixing performance by stirring or agitating the fluid flow using some form of external energy supply. As shown in Figure 1, active mixers typically use acoustic/ultrasonic, dielectrophoretic, electrokinetic time-pulse, pressure perturbation, electro-hydrodynamic, magnetic or thermal techniques to enhance the mixing performance [1–11,26–57]. [Figure: Categories of active microfluidic mixer.] Acoustic/Ultrasonic Actuation [26–30] 2.1. Liu et al. [26] demonstrated the use of acoustically-induced microstreams to achieve mixing in a micro-chamber. In the design, a piezoelectric disk was used to excite air bubbles trapped in the top layer of the chamber at a frequency of 5 kHz. The mixing time was reported to be 6 s for a 40 V peak-to-peak excitation. Adopting a similar configuration, Yang et al. [27] employed a higher frequency of approximately 60 kHz and a 50 V peak-to-peak excitation in an attempt to accelerate the mixing process. However, the increased agitation of the fluid samples resulted in a temperature rise of 16 °C in the chamber. Tsao et al. [28] presented a Lamb wave micromixer in which Lamb waves were induced in the mixing species by a thin plate formed at one side of the mixing chamber and integrated with interdigitated transducers. Rife et al. [29] proposed a radio frequency-based microfluidic device with an operational frequency of 50 MHz that applied acoustic streaming to both pump and mix the sample species. Yaralioglu et al. [30] presented a micromixer featuring a simple microfluidic channel with embedded piezoelectric transducers and an operational frequency of 450 MHz. Through the application of an external electrical field, the transducers generated a strong acoustic streaming effect, enhancing species mixing within the channel. Dielectrophoretic Force Actuation [31,32] 2.2. When the dielectrophoretic (DEP) force is applied to mixing, non-uniform alternating electrical fields induce the motion of polarized particles/cells [31]. The electrical field generates a dipole moment on the particles and the interaction between the induced dipole charges and the electrical field generates a net force which drives the particles either towards or away from the