Multiplexed DNA sequence capture of mitochondrial genomes using PCR products.
Maricic T, Whitten M, Pääbo S. · 2010
Read Multiplexed DNA sequence capture of mitochondrial genomes using PCR products. by Maricic T, Whitten M, Pääbo S. (2010) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc2982832.txt.
Introduction
Maricic, Whitten, and Pääbo described a cheap way to fish out complete mitochondrial genomes from mixed DNA in a 2010 methods study. Enrichment tools usually need pricey commercial kits and suit short targets poorly.
Their trick uses tailor-made long copying products as bait to capture whole mitochondrial genomes, several kilobases long. In one run they captured forty-six genomes in parallel and read them on a single lane of a high-throughput sequencer. Because the approach is simple and economical, it fits population genetics, forensics, and ancient DNA work where many mitochondrial genomes are wanted at once.
Catalog record
| CREATOR | Maricic T, Whitten M, Pääbo S. |
|---|---|
| YEAR | 2010 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 15 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Multiplexed DNA Sequence Capture of Mitochondrial Genomes Using PCR Products By Tomislav Maricic, Mark Whitten, Svante Pääbo, Robert C. Fleischer Published in: PLoS ONE DOI: 10.1371/journal.pone.0014004 ABSTRACT Background To utilize the power of high-throughput sequencers, target enrichment methods have been developed. The majority of these require reagents and equipment that are only available from commercial vendors and are not suitable for the targets that are a few kilobases in length. Methodology/Principal Findings We describe a novel and economical method in which custom made long-range PCR products are used to capture complete human mitochondrial genomes from complex DNA mixtures. We use the method to capture 46 complete mitochondrial genomes in parallel and we sequence them on a single lane of an Illumina GAII instrument. Conclusions/Significance This method is economical and simple and particularly suitable for targets that can be amplified by PCR and do not contain highly repetitive sequences such as mtDNA. It has applications in population genetics and forensics, as well as studies of ancient DNA. INTRODUCTION Methods that enrich DNA samples for particular DNA sequences are important in order to allow efficient sequencing of targets that are present in complex mixtures of irrelevant DNA sequences. These may either be entire genomes of organisms under study or DNA from several organisms in environmental or medical samples [1], [2]. Methods that are able to “capture” relevant DNA sequences rely on hybridization of target sequences to probes that can be either in solution or immobilized on a surface (e.g. [3], [4], [5]). The hybridization is sometimes followed by extensions [2] or extension in combination with circularization of the probes [6]. Other methods rely on micro-droplet-based selection [7]. Although all these methods achieve their goals, they involve probes and/or equipment that have to be purchased from manufacturers at substantial costs as well as loss of time. Here, we present a method where PCR products are used to capture targets for sequencing from pooled sequencing libraries of multiple individuals, using standard laboratory equipment. We apply this method to DNA pools of libraries from several human individuals from which we capture complete mitochondrial (mt) DNAs, a maternally inherited DNA molecule which is extensively studied in population genetics, medicine, forensics, and phylogenetics [8]. MATERIALS AND METHODS Production of indexed libraries DNA extracts of 46 individuals from which the hypervariable region I had been sequenced [9] were used for indexed Solexa library preparation. First, eight hundred ng of DNA were sonicated (Bioruptor, Diogenode, Liege, Belgium) five times for seven minutes with the output selector switched to (H)igh. This fragmented the DNA to a range of 150 to 800 base-pairs. Two hundred ng were then used for the production of the indexed libraries as published [10], starting from the blunting step. In the last step of the protocol, the indexing amplification was run into plateau (20 cycles) and the reactions were purified using a MinElute PCR purification kit (Qiagen, Hilden, Germany). DNA concentrations of individual libraries were measured with a spectrophotometer (NanoDrop ND-1000, Thermo Scientific, Wilmington, DE, USA) and the libraries were pooled in equimolar amounts to a total of 2 µg. Bait production Two overlapping long-range PCR products encompassing the whole mitochondrial genome were produced as described [11]; DNA extracted from the saliva of one individual was used as the template. The PCR products were purified using carboxyl-coated magnetic beads (SPRI beads, Agencourt AMPure XP, Agencourt, Beverly, MA, USA) and the concentration was measured by NanoDrop. The two products were pooled in equimolar amounts to a total amount of 3 µg; the pooled products were sonicated (Bioruptor) two times for seven minutes with the output selector switched to (H)igh which produced fragments from 150 to 850 bases long. The products were biotinylated by ligating the Bio-T/B adapter (sequence in Supplementary protocol S1), MinElute column purified, made single-stranded and immobilized on streptavidin-coated magnetic beads. Hybridization The pooled libraries were made single-stranded and added to the bait-coated beads; the mixture was attached to a rotator and rotated at 65°C in a hybridization oven (SciGene, Model 700, Sunnyvale, CA, USA). After 48 hours, library molecules that did not hybridize to the bait were washed away and the enriched library pool was eluted by heating for 3 minutes at 95°C. The DNA concentration was measured by qPCR (Mx3005P Real Time PCR System, Stratagene, La Jolla, CA), the pool was further amplified for 15 cycles using the bridge primers (sequence in Supplementary protocol S1) and purified with the SPRI beads; the concentration of the 22 µl eluate was determined with the Bioanalyzer 2100 DNA 1000 chip (Agilent Santa Clara, CA). Sequencing Libraries were sequenced with 76+7 cycles on one lane of an Illumina flow cell (Cluster Generation kit V2, FC-103-300x sequencing chemistry) according to the manufacturer's instructions for Single Read Multiplex sequencing on the Genome Analyzer IIx platform. The run was processed with RTA 1.5 (Illumina Inc.). Afterwards, the PhiX 174 control reads were aligned to the corresponding reference sequence to obtain a training data set for the base caller Ibis [12]. Raw sequences called from Ibis were separated by sample using their index read (allowing one mismatch and the loss of the first base) [12]. Sequences obtained for each sample were searched for the adapter sequence (AGATCGGAAGAGCACACGTCTGAACTCCAG) and read ends trimmed back when they could represent adapter sequence. Further, reads were filtered for sequence quality and complexity. In this step, reads having more than 5 bases with a quality score below 10 (PHRED score) [12] and reads with sequence entropy below 0.85 were removed (where entropy was calculated by summing -p*log2(p) for each of the four bases; p is the frequency of a base in the read). Assembly The reads for each of the 46 samples were mapped to the revised Cambridge reference mitochondrial sequence (NC012920.1) using the iterative mapping assembler MIA [13]. Mapping allowed for up to four mismatches or three mismatches and one indel in a 76 base long read. Reads starting and ending at the same coordinate were then collapsed, making one consensus read by taking the highest quality base for each position [14]. From the mapped reads, consensus mitochondrial sequence was called: a base was called in the consensus sequence if the score for the base was a positive number (200 points are given for match, −600 for mismatch, and −100 for an N in the read), otherwise an N was called. RESULTS AND DISCUSSION Equimolar amounts of two long-range PCR products which together encompass the complete mitochondrial genome, which is a double-stranded circular molecule of 16,6 kb, were pooled and fragmented by sonication, ligated to a biotinylated DNA adapter, denatured, and immobilized on streptavidin-coated magnetic beads (Figure 1, top left). The immobilization prevents self-hybridization of the bait molecules that occur if they are free in solution. DNA extracted from blood or saliva from 46 individuals [9] were used to produce indexed Solexa libraries [10], which were pooled in equimolar amounts, denatured (Figure 1, top right) and incubated with the beads for 48 hours. The beads were then washed and the captured molecules were heat-eluted, amplified and sequenced (Figure 1, bottom) on one lane of a Solexa Genome Analyzer II. [Figure: Overview of the capture-on-beads method.On the left the production of the immobilized bait from two long